Example: tourism industry

Product Catalog - Buckeye Fire Equipment

Product Catalog Your Source for World Class Fire Protection Equipment Foam Concentrates Restaurant Fire Hand Held Wheeled & Specialty & Hardware Suppression Systems Extinguishers Fire Extinguishers 1. Hand Held Fire Extinguishers | Page 4-12. ABC Dry Chemical | Page 5. Standard Dry Chemical | Page 6. Purple K Dry Chemical | Page 7. Halotron | Page 8. Carbon Dioxide | Page 9. Water & Water Mist | Page 10. Wet Chemical - Class K | Page 11. Dry Powder - Class D | Page 12. Automatic Spot Protection Fire Extinguishers | Page 13-14. Vertical Mini-Guards | Page 13. Horizontal Mini-Guards | Page 14. Wheeled Fire Extinguishers | Page 15-19. Wheeled Halotron | Page 15. Wheeled Dry Chemical | Page 16-18.

2 American Made Since 1968 For over four decades Buckeye Fire Equipment has been an international leader in the development and manufacture of reliable fire protection products. A privately owned and operated company

Tags:

  Product, Catalog, Product catalog, Buckeye

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Catalog - Buckeye Fire Equipment

1 Product Catalog Your Source for World Class Fire Protection Equipment Foam Concentrates Restaurant Fire Hand Held Wheeled & Specialty & Hardware Suppression Systems Extinguishers Fire Extinguishers 1. Hand Held Fire Extinguishers | Page 4-12. ABC Dry Chemical | Page 5. Standard Dry Chemical | Page 6. Purple K Dry Chemical | Page 7. Halotron | Page 8. Carbon Dioxide | Page 9. Water & Water Mist | Page 10. Wet Chemical - Class K | Page 11. Dry Powder - Class D | Page 12. Automatic Spot Protection Fire Extinguishers | Page 13-14. Vertical Mini-Guards | Page 13. Horizontal Mini-Guards | Page 14. Wheeled Fire Extinguishers | Page 15-19. Wheeled Halotron | Page 15. Wheeled Dry Chemical | Page 16-18.

2 Wheeled Carbon Dioxide | Page 19. Restaurant Fire Suppression Systems | Page 20-21. Foam Concentrates & Hardware | Page 22-23. Recharge Agents | Page 24. Mounting Hardware | Page 25-26. Wall Hooks | Page 25. Marine/Vehicle Brackets | Page 26. Hand Held, Wheeled &. Specialty Fire Extinguishers Foam Concentrates & Hardware Restaurant Fire Suppression Systems 2. American Made Since 1968 Selection Guide For over four decades Buckeye Fire To provide the best protection of life and property from fire, it is critical that the proper Equipment has been an international extinguisher selection be made. The classification and rating of an extinguisher are leader in the development and vital pieces of information for making this selection.

3 Manufacture of reliable fire protection The National Fire Protection Association (NFPA) has established the requirements for products. the number, size, placement, performance and maintenance of A privately owned and operated company portable fire extinguishers. These requirements are contained in NFPA 10, Standard with its headquarters near Charlotte, NC, for Portable Fire Extinguishers . Buckeye Fire Equipment has earned an excellent reputation for quality, reliability Within this standard it is stated that the selection of fire extinguishers for a given and value within the commercial and situation is determined by the following: industrial fire protection industry. the character and size of the fires anticipated to be encountered.

4 We offer a complete line of handheld and the construction and occupancy of the property to be protected. wheeled fire extinguishers, extinguishing agents, fire suppressing foam concentrates the ambient temperature of the area where the extinguisher will be located. & hardware and pre-engineered kitchen other factors that may dictate the selection of a particular type of extinguisher. suppression systems. To ensure our distributors and customers Fire Classifications get the highest quality fire protection Generally fire extinguishers are selected based on the hazard(s) they are intended to Equipment , all of our products undergo protect. Classifications have been established to categorize these hazards as follows: rigorous testing, both in-house and by third party testing organizations such as Class A: Fires involving ordinary combustible materials such as wood, Underwriters Laboratories, Canada, cloth, paper, rubber and many plastics.

5 Factory Mutual, ASME and the Government. Class B: Fires involving flammable liquids, combustible liquids, petroleum grease, tars, oils, oil based paints, solvents, lacquers, alcohols, and flammable We are committed to helpful and responsive gases. customer service and knowledgeable Class C: Fires that involve energized electrical Equipment . and dependable technical support. This commitment has earned Buckeye Fire Equipment the coveted ISO 9001-2008. Class D: Fires involving combustible metals such as magnesium, Quality Certification. sodium, potassium and titanium. Contact us for more information about the wide selection of Buckeye Fire Equipment Class K: Fires involving combustible cooking media such as vegetable Company products and services.

6 We have oils, animal oils and fats. trained personnel who are ready to assist you with your fire protection needs. 3. Fire Ratings Placement/Accessibility Of Extinguisher Along with the classification, the numerical Fire Classification Class A Class B Class C Class D Class K. rating of an extinguisher is an important Maximum Travel 75 Feet 50 Feet In accordance 75 Feet 30 Feet factor in the proper selection of an Distance To Fire Maximum Maximum with the Class Maximum Extinguisher area that one area that one A or B hazard area that one extinguisher. The rating is a measure of extinguisher extinguisher it is protecting extinguisher the extinguishing potential of the fire can protect can protect can protect extinguisher and is developed on the and meet the and meet the and meet the basis of comparative fire tests.

7 75 ft. rule = 50 ft. rule = 30 ft. rule =. 11,250 sq. 5,000 sq. 1,800 sq. ft. Only Class A and Class B classifications carry numerical ratings. Basically the Occupancy Hazards higher the number associated with the classification letter, the larger the fire The NFPA classifies occupancies as either boat servicing; cooking areas; individual the extinguisher has the potential to Low, Moderate or High Hazard. Product display showrooms; Product extinguish. convention center displays; and storage Low hazard occupancies are and manufacturing processes such as Class A fire tests involve two types of locations where the total amount of painting, dipping, and coating, including fire, a wood crib fire test and a wood Class A combustible materials and Class flammable liquid handling.

8 Panel fire test. For example to achieve B flammables, including furnishings, a 3-A rating an extinguisher must decorations, and contents, is of minor Occupancies Min. Rating Unit of A. successfully extinguish a burning wood quantity. This can include some buildings Low 2-A:5/10-B 3000. crib measuring 29 x 29 x 27 and a or rooms occupied as offices, classrooms, Moderate 2-A:10/20-B 1500. wood panel measuring 12' x 12'. churches, assembly halls, guest room High 4-A:40/80-B 1000. areas of hotels/motels. Class B fire tests involve square pans Note: If the lower B rating is installed then the containing flammable liquid. Moderate hazard occupancies are locations maximum travel distance to the extinguisher is reduced from 50 to 30 feet.

9 Where the total amount of Class A. For example to achieve a 40-B rating an combustibles and Class B flammables To determine the overall A rating necessary extinguisher must successfully extinguish are present in greater amounts than for protection of an occupancy, divide the a burning pan measuring 100 sq. ft. expected under low hazard occupancies. total sq. ft. by the Unit of A in the above There are no numerical ratings associated table. For example if a low occupancy These occupancies could consist of with Class C, D or K. building has a total sq. ft. of 30,000. dining areas, mercantile shops and allied For Class C, the electrical nonconducting storage, light manufacturing, research Divide 30,000 x 3000 (Unit of A) = 10.

10 Characteristics of the agent are verified, operations, auto showrooms, parking Therefore in this example the building not its extinguishing potential. garages and workshops. would require a minimum of five 2-A. For Class D, only the amount of agent High hazard occupancies are rated extinguishers. and application method needed to locations where the total amount of Class This ABC extinguisher is rated control a metal fire of a certain size and A combustibles and Class B flammables 3-A:40-B:C. The 3 and the 40. type is tested. indicate the extinguishing present, in storage, production, use, potential for Class A and Class finished Product , or combination thereof, B fires respectively. The C. For Class K, the extinguisher must is over and above those expected in indicates that the agent will extinguish 80 lbs.