Product Catalog - Direct-Fired Make-Up Air Units Model ...

November 2009 MUA-PRC007-ENDirect-Fired Make-Up Air UnitsDFIADFOAP roduct Catalog 2009 Trane All rights reserved MUA-PRC007-ENIntroductionWhy use Trane Makeup Air s innovative Direct Fired gas heating systems add warm, fresh and clean air to your work environment for about 20 precent less than the operation and maintenance costs of indirect gas heat. Heats Without Complications: The Direct Fired gas heating system heats efficiently and cost-effectively using no heat exchanger. Replaces Indoor Air: The Direct Fired gas heating system replaces indoor air that can become chemical laden in an industrial process or commercial cooling application.

MUA-PRC007-EN 3 Introduction Installation is simple since the unit, (when shippi ng permits), is shipped as a complete package. The burner is fully modulating, wi th a minimum firing rate of four percent of full input. This characteristic results in just the right amount of heat under all operating conditions. Industry Approval ETL Labeling ...

Tags:

  Product, Catalog, Product catalog

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Catalog - Direct-Fired Make-Up Air Units Model ...

1 November 2009 MUA-PRC007-ENDirect-Fired Make-Up Air UnitsDFIADFOAP roduct Catalog 2009 Trane All rights reserved MUA-PRC007-ENIntroductionWhy use Trane Makeup Air s innovative Direct Fired gas heating systems add warm, fresh and clean air to your work environment for about 20 precent less than the operation and maintenance costs of indirect gas heat. Heats Without Complications: The Direct Fired gas heating system heats efficiently and cost-effectively using no heat exchanger. Replaces Indoor Air: The Direct Fired gas heating system replaces indoor air that can become chemical laden in an industrial process or commercial cooling application.

2 Provides Ventilation: Fresh air is available simply by turning off the heating section. Cleans and Tempers Incoming Air: The optional filter bank removes airborne particles, and cleaned air is heated to create a more refreshing and comfortable indoor environment. Trane offers two styles of Direct Fired gas heating systems: Indoor Units (DFIA) Large outdoor Units (DFOA)What Is Make-Up Air? Make-Up air is an outside air supply that is brought in to relieve air starvation. Without Make-Up air, a building is under a negative condition and the following will occur: Backdrafts in natural flues, ventilators and stacks.

3 Reduced air volume handled by the exhaust fans and subsequently inadequate removal of contaminants. Dispersal of contaminants throughout the work area by high velocity cross-currents from uncontrolled outside air sources. Uncomfortable and unhealthy working conditions. Pilot outages. When Is It Required? Make-Up air is required whenever exhaust fans are used. This need for a building air change arises when there are: Processes which generate contaminants in the form of noxious fumes or dust. Activities which create excessive heat or undesirable odors. Hazardous material storage areas.

4 Ventilation requirements for a building s inhabitants. State and local code Use Make-Up Air Units ? Outside air should not be allowed to drift in through windows, door cracks and other openings, creating a strain on the heating system. Outside air should be controlled, tempered and coordinated with the exhaust by a Make-Up air unit. The latter is reliable, efficient and does not disrupt building activities. Why Use Direct Gas-Firing?Maximum economy is realized with direct gas-firing because the incoming air is heated directly in the burner chamber. This provides 100 percent efficiency (92 percent sensible, 8 percent latent) while eliminating a heat exchanger or combustion chamber that could burn out or corrode.

5 Trane Direct-Fired Units are factory tested, include the necessary controls for operating the system and generally cost less than alternate systems. MUA-PRC007-EN3 IntroductionInstallation is simple since the unit, (when shipping permits), is shipped as a complete package. The burner is fully modulating, with a minimum firing rate of four percent of full input. This characteristic results in just the right amount of heat under all operating conditions. Industry ApprovalETL Labeling RequirementsA DFOA/DFIA unit can bear the ETL label if: The unit airflow is within the SCFM range shown in Ta b l e 3 , p.

6 1 8 (DFIA) and Table 12, p. 33 (DFOA). The fuel is natural gas with a temperature rise not greater than 130 F or the fuel is LP and the temperature rise not greater than 100 F. The motor is a single speed motor, or if the motor is a two speed motor, the burner will operate in only one of the two speeds (high or low speed). Unit components are standard (there are exceptions to this). If the unit has return air, the unit must have a mixing box with the AdaptAire airflow Emission Levels: If the unit has an ETL label, the maximum levels of the products of combustion meet ANSI which are: Carbon Dioxide 4000 ppm Carbon Monoxide 5 ppm Aliphatic Aldehydes 1 ppm Nitrogen Dioxide ppmCETL Labeling Requirements (Canada)A DFOA/DFIA unit will have a CETL label if the unit meets the first five items of ETL Labeling Requirements (above), AND the unit does not have return and the Trane logo are trademarks of Trane in the United States and other countries.

7 All trademarks referenced in this document are the trademarks of their respective owners. 4 MUA-PRC007-ENTable of ContentsIntroduction .. 2 Application Considerations .. 6 The Need for Make-Up Air Units .. 6 Outdoor Units .. 6 What Fuel to Use? .. 7 Selection Procedure .. 8 Burner Selection Procedure .. 9 Unit Configuration .. 10 Horizontal Configurations .. 10 Vertical Configurations (DFOA only) .. 10 Vertical Configurations (DFIA only) .. 11 DFIA .. 12 Model Number Descriptions .. 12 Features and Benefits .. 14 Reliable Operation .. 15 Equipment Approval Options.

8 15 Special Construction Features .. 15 Performance Data .. 16 Dimensions .. 21 Weights .. 26 DFOA .. 27 Model Number Descriptions .. 27 Features and Benefits .. 29 Basic Unit .. 30 Gas-Fired Unit .. 30 Performance Data .. 31 Dimensions .. 36 Gas Piping .. 54 Electrical Power .. 59 Options .. 60 Motorized 75/25 Damper .. 60 Mixing Box Temperature Control .. 61 Mixing Box Manual Control .. 61 Mixing Box Building Pressure Control .. 63 Motorized Inlet Damper .. 63 Exhaust Interlock .. 64 MUA-PRC007-EN5UV Flame Sensor (UV Mini-Peeper) .. 65 Optional Gas Controls.

9 65 Factory Installed Options .. 65 Additional Options* .. 66 Additional Factory Installed Options .. 67 Field Installed Accessories .. 68 Mechanical Specifications .. 706 MUA-PRC007-ENApplication ConsiderationsThe Need for Make-Up Air Units When more air is exhausted from a building than is supplied by the mechanical systems, the building is under a negative condition. Air will leak into the building through cracks, windows, and doors. Make-Up air Units are typically used to compensate for air being exhausted from a building or other structure. Application for closed systems such as ovens or paint booths (consult home office).

10 For use as a door heater where outside air is heated and not prevented from infiltrating. The DFOA/DFIA can be used as an air handler, no burner section. Can also be used with DX, electric, CW, HW and steam coils. Contact your Trane Units Outdoor Make-Up air Units are the most common approach to relieving negative pressure inside commercial and industrial facilities. All Units offer the advantage of a full support system that is watertight, provides a plenum for return air, and has easily accessible piping and electrical connections. When a negative condition exists: Flues and stacks may experience a backdraft and cause dangerous contaminants to remain in the occupied space.