Example: stock market

Product Catalogue - Kirloskar Brothers

KS6 / 7/ 8 KS6 / 7/ 8 Product CatalogueFeatures Huge savings in electrical consumption Capability to withstand wide voltage fluctuations Operates equally well with Genset, great help during power cuts Non-overloading power characteristics protect the motor Water lubricated bearings for years of service Design of non-returnable valve reduces friction Minimum possible diameters for easier setting into the borewell Dynamically balanced rotating parts Nitril rubber bushes ensure long life of pump even in muddy water CED coating cast iron components long life & rust freeMaterial of Construction Applications Continuous water supply for farming application & irrigation projects Fire fighting application Range Head : 5-306 metresDischarge : 2400-60 LPMM otor Rating.

KS6 /7/ 8 Product Catalogue Features" Huge savings in electrical consumption " Capability to withstand wide voltage fluctuations" Operates equally well with Genset,

Tags:

  Product, Catalogue, Product catalogue

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Catalogue - Kirloskar Brothers

1 KS6 / 7/ 8 KS6 / 7/ 8 Product CatalogueFeatures Huge savings in electrical consumption Capability to withstand wide voltage fluctuations Operates equally well with Genset, great help during power cuts Non-overloading power characteristics protect the motor Water lubricated bearings for years of service Design of non-returnable valve reduces friction Minimum possible diameters for easier setting into the borewell Dynamically balanced rotating parts Nitril rubber bushes ensure long life of pump even in muddy water CED coating cast iron components long life & rust freeMaterial of Construction Applications Continuous water supply for farming application & irrigation projects Fire fighting application Range Head : 5-306 metresDischarge : 2400-60 LPMM otor Rating.

2 KW- 33 kW ( - HP)Borewell Size : 150mm (6 ) 200mm (8 ) Voltage Range: 200 V - 440 VParts Impeller Diffusets Pump BowlMotor Casing Pump Shaft Motor Shaft KS 6"/7"/8"Bronze Gr LTB2 /20% Glass Filled Noryl20% Glass Filled Noryl-Stainless Steel Stainless SteelStainless SteelKS 6"/7"/8"Bronze Gr LTB2-High Graded Cast IronStainless SteelStainless SteelStainless SteelCABLE SIZEMOTORRATINGFULL LOADCURRENTkWHP(AMPS) OF CABLE IN METRES---------------------oCable Selection Chart for 415 Volts, 50 Hz, 3 Phase Motors (Considering Ambient Temp. 50 & 3% Voltage Drop)9 Cable Size Selection for 3 150 MM S/D 2 2x3x4mm2 S/D 2 2x3x4mm2 S/D 2 2x3x4mm2 S/D 2 2x3x4mm2 2x3x6mm2 2x3x10mm StartingCable size recommendedfor upto 45 M Cable lengthCable size recommendedfor upto 70 M Cable lengthCable size recommendedfor upto 95 M Cable lengthS/D S/D S/D S/D DOL DOL DOL DOL 2x3x4mm2 2x3x4mm2 2x3x4mm2 2x3x4mm2 2x3x6mm2 2x3x6mm2 2x3x6mm2 2x3x6mm2 1x3x4mm2 1x3x4mm2 1x3x6mm2 / 7/ 8 Submersible PumpsKIRLOSKARKS6 B SeriesPIPE SIZE.

3 50mmPUMPMODELPOWER RATINGDISCHARGE IN LPMHPkWTOTAL HEAD IN C SeriesPIPE SIZE: 50mmPUMPMODELPOWER RATINGDISCHARGE IN LPMHPkWTOTAL HEAD IN D SeriesPIPE SIZE: 65mmPUMPMODELPOWER RATINGDISCHARGE IN LPMHPkWTOTAL HEAD IN E SeriesPIPE SIZE: 65mmPUMPMODELPOWER RATINGDISCHARGE IN LPMHPkWTOTAL HEAD IN F SeriesPIPE SIZE: 80mmPUMPMODELPOWER RATINGDISCHARGE IN LPMHPkWTOTAL HEAD IN G SeriesPIPE SIZE: 100mmPUMPMODELPOWER RATINGDISCHARGE IN LPMHPkWTOTAL HEAD IN RATINGDISCHARGE IN LPMHPTOTAL HEAD IN A SeriesPIPE SIZE: 50mmPERFORMANCE-150mm (6 ) Submersible 10 Product CataloguePerformance chart for KS 7P Pumps PUMPMODELPOWERRATINGDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN SIZE: 100 mmFULL LOADCURRENT(AMPS)RATEDVOLTAGE(V) CataloguePUMPMODELMODELRATINGDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN mm (7 ) Submersible KS7 A Series PIPE SIZE: 100mmPerformance chart for KS8 A Pumps PUMPMODELMODELRATINGDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN * Above models can be made available with both 8 and 6 Motors.

4 * Above models can be made available with 8 Motors only. PIPE SIZE: 100 mm1112 Note: Performance applicable to liquid of specific gravity 1 and viscosity as of water. Performance chart for KS8B PumpsPUMPMODELMODELRATINGDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN * Above models can be made available with both 8 and 6 Motors. * Above models can be made available with 8 Motors SIZE: 125mmPerformance chart for KS8P Pumps PUMPMODELPOWERRATINGDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN METRESkWHP240120014401680 PIPE SIZE: 100 mmFULL LOADCURRENT(AMPS)RATEDVOLTAGE(V) CatalogueFeaturesPump Higher head per stage resulting in achieving same head with less no of stages Stainless Steel pump internals Better surface finish hence better efficiency and consistent performance.

5 Lesser weight and lesser height resulting into ease in installation and transportation Better life in sandy water application Better life in acidic water Rust free water Aesthetically appealing Loading on pipes improves CED coating cast iron components long life & rust free Motor Withstand wide voltage fluctuations from 200 volts to 440 volts with marginal variation in head anddischarge Even at low voltage, pump delivers water For longer life Teflon Carbon Thrust bearing Better protection against sand Material of Construction Impeller : Stainless Steel Diffuser : Stainless Steel Diffuser Casing : Stainless SteelShaft : Stainless SteelNRV : CIDischarge outlet : CISuction Housing : CIBearing Sleeve : Hard Chrome Stainless SteelBearing Bush: RubberUse from (Higher Depth) Water supply for Industrial, Housing Complex, Hotels, Hospitals, Commercial Complex, Cinema Halls, Multiplex, Community Supplies, Building & Construction application Continuous water supply for farming application & irrigation projects Fire fighting application Range Head : 1 - 447 metres Discharge : 740-30 LPMM otor Rating : kW-15 kW ( HP)Borewell Size.

6 150 mm (6 )Voltage Range : 200 V -440 VProduct CatalogueSTARTING METHOD / CABLE CONNECTION 150mm (6 )DOL Start / Single Cable Star Delta Start / Double Cable Standard Model Upto HP10 HP & above oCable Selection Chart for 415 Volts, 50 Hz, 3 Phase Motors (Considering Ambient Temp. 50 & 3% Voltage Drop)MOTORRATINGFULL LOADCURRENT CABLE SIZEkWHP(AMPS) OF CABLE IN METRES PUMPHigh Head Submersible PumpKIRLOSKAR14 DISCHARGE IN LITRES PER MINUTETOTAL HEAD IN METRESRATEDCURRENT(AMPS) Performance 50HH Series PIPE SIZE: 50mm60HH SeriesPIPE SIZE: 50mmDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN METRESRATEDCURRENT(AMPS) SeriesPIPE SIZE: 50mmDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN METRESRATEDCURRENT(AMPS) CatalogueNote: Performance applicable to liquid of specific gravity 1 and viscosity as of water.

7 Pumps can be supplied on demand in 65mm dia also in 100HH, 125HH & 150 HH series. 100HH SeriesPIPE SIZE: 50mmDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN METRESRATEDCURRENT(AMPS) SeriesPIPE SIZE: 50mmDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN METRESRATEDCURRENT(AMPS) SeriesPIPE SIZE: 50mmDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN METRESRATEDCURRENT(AMPS) SeriesPIPE SIZE: 65mmDISCHARGE IN LITRES PER MINUTETOTAL HEAD IN METRESRATEDCURRENT(AMPS) Catalogue1516 Portable and hygienic grade of oil-filled motor facilitates use of anti-friction bearings (instead of journal bearings) resulting in smooth running and trouble-free operation of pumpset.

8 Stator is easily rewindable. Insulation : Class 'F'. Wider voltage range : Three Phase 280 V to 430V (Rated Voltage : 415V) Maximum starts / stops per hour : 30 Applications Sprinkler and drip irrigation systems Farm houses, nurseries and gardeningRange Head : 7-248 metres Capacity: 320-5 LPMR ating : kW ( HP) for three phase Material of Construction PumpPump Housing : Stainless Steel Pump Shaft : Stainless SteelSuction Bracket : Stainless SteelDischarge Nozzle: Stainless SteelStage Bowl : Stainless SteelImpellers: Noryl Diffusers: NorylStrainer : Stainless SteelMotor Motor Housing : Stainless SteelMotor Shaft.

9 Stainless SteelMotor Topshield: Cast Iron (Ni plated)All Hardware : Stainless SteelFeaturesPump Motor: Anti-friction bearings for axial / radial loads givebetter life to motor. Light weight and compact. Higher efficiency resulting in lower operating cost Unique design of impellers and diffusers leading to reduction in axial thrust on motor shaft. Non overloading power characteristics ensures trouble free operation in the entire operating range. Lower number of stages for a given performance. Easy assembling, dismantling and repairing; because of hexagonal shaft design. Strainer is inside the housing, hence no chance of damage.

10 Can be installed with HDPE / UPVC / GI pipes. Flatter efficiency curve ensures better performance in the entire operating range. Can also be installed horizontally. 3 OWINNER -03 PIPE SIZE: 32mmMODELR ated CurrentDISCHARGE IN LPM1035 TOTAL HEAD IN TKU4-0310 TKU4-0311 TKU4-0314 TKU4-0318 TKU4-0321 TKU4-0328 TKU4-0334 TKU4-0340 T 42 39 36 32 28 1762 60 56 51 46 40 2470 65 62 57 51 44 2686 83 79 72 65 55 33111 107 101 93 83 72 43130 125 118 108 97 84 50172 167 157144 129 112 67210 202 191 175 157 136 80248 238 225 206 185 160 963 OWINNER -02 PIPE SIZE: 32mmMODELR ated CurrentDISCHARGE IN LPM530 TOTAL HEAD IN METRESKU4-0214 TKU4-0228 TKU4-0234 TKU4-0240 SUBMERSIBLEKU4 WINNERKU4 WINNERP roduct CatalogueProduct CatalogueCable Selection Chart at Rated Voltage, 50 Hz, Single / Three Phase Motors o(Considering Ambient Temperature, 40c and 3% Voltage Drop)Note : The table states the maximum allowable length in metres for three core, flat PVC sheathed, submersible copper cables for installation where site voltages are normal.