48 TCGas Heat/Electric CoolingPackaged Rooftop3to15 NominalTonsProduct DataC08613the environmentally sound refrigerant2 TABLE OF CONTENTSPAGEFEATURES AND NUMBER OPTIONS AND/OR COOLING RATING RATING PERFORMANCE & WEIGHTS PRESSURE / WIRING OF Carrier rooftop unit (RTU) was designed by customers for customers. With no--strip screw collars, handled accesspanels, and more we ve made your unit easy to install, easy to maintain and easy to to install:All WeatherMakerrunits are field--convertible to horizontal air flow which makes it easy to adjust to adjust to unexpectedjob site complications. Lighter units make easy replacement. Most Carrier 48TC rooftops fit on existing Carrier curbsdating back to 1989.

48TC Gas Heat/Electric Cooling Packaged Rooftop 3to15NominalTons Product Data C08613 the environmentally sound refrigerant

Tags:

  Product, Data, Product data

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Data - Arizona Air Conditioning And …

1 48 TCGas Heat/Electric CoolingPackaged Rooftop3to15 NominalTonsProduct DataC08613the environmentally sound refrigerant2 TABLE OF CONTENTSPAGEFEATURES AND NUMBER OPTIONS AND/OR COOLING RATING RATING PERFORMANCE & WEIGHTS PRESSURE / WIRING OF Carrier rooftop unit (RTU) was designed by customers for customers. With no--strip screw collars, handled accesspanels, and more we ve made your unit easy to install, easy to maintain and easy to to install:All WeatherMakerrunits are field--convertible to horizontal air flow which makes it easy to adjust to adjust to unexpectedjob site complications. Lighter units make easy replacement. Most Carrier 48TC rooftops fit on existing Carrier curbsdating back to 1989.

2 Also, our large control box gives you room to work and roomto mount Carrier accessory to maintain:Easy access handles by Carrier provide quick and easy access to all normally serviced components. Our no--strip screwsystem has superior holding power and guides screws into position while preventing the screw from stripping the unit smetal. Take accurate pressure readingsby reading condenser pressure with panels on. Simply remove the black, compositeplug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s).Easy to use:The newly designed, central terminal board by Carrier puts all your connections and troubleshooting points in oneconvenient place, standard. Most low voltage connections are made to the same board and make it easy to find what you relooking for and easy to access it.

3 Carrier rooftops have high and lowpressure switches, a filter drier, and 2--in (51mm)filters environmentally sound refrigerant48TC3 FEATURES AND BENEFITSSS ingle cooling stage models are available from 3 -- 10 cooling stage models are available from -- 15 up to s up to s up to to 28% lighter than similar industry units. Lighter rooftops make easier replacement connections are the same because 3 -- ton units fit on existing Carrier rooftop curbs. This saves time andmoney on replacement components and layout. Standardized components and controls make service and stocking parts compressors on all units. This makes service, stocking parts, replacement, and troubleshooting convertible airflow (3 -- 15 ton).

4 Being able to convert a unit from vertical airflow to horizontal makes it easy toovercome job site complications. 15 ton models require a simple supply duct cover to field convert from factory verticalto , belt--drive motor available. Carrier provides a factory solution for most points in the fan performance for bottom or side condensate of thru--the--base or thru--the--curb gas line gas / electrical , composite drain pan. Sloped, composite drain pan sheds water; and won t controls & control box layout. Standardized components & controls make stocking parts & service filter access , easy to use control , laminated wiring and power wiring drawings which are affixed to unit make troubleshooting , central terminal board for test and wiring , handled, panels for easy access on normally accessed service No--strip screw system guides screws into the panel & captures them tightly without stripping the screw, the panel, orthe , newly--design indoorrefrigerant header for easier maintenance and cooling (115_Fto40_For46_Cto4_C) standard on all models.

5 Winter Start Kit allows cooling operationdownto25_F(--4_C) and Motor Master to --20_F(--29_C).SHigh efficiency, gas heat with induced--draft flue exhaust draft motor ensures no flue gas can escape into the indoor air designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to beperiodically, manually drained. This saves labor and maintenance (51mm) disposable filters on all filter--drier on each circuit is protected with a high and low pressure factory--installed options ranging from air management economizers, 2 position dampers, plus convenienceoutlets, disconnect switch and smoke Warranty: 10 yr. aluminized heat exchanger, 5 yr. compressor, 3 yr. Novation condenser coil, 1 yr.

6 Humidi--MiZerradaptive dehumidification system on all sizes with round tube / plate fin condensercoils, includes MotorMaster I NUMBER NOMENCLATURE1234567891011121314151617184 8 TCDA04A1A5--0A0A0_____Unit TypeBrand / Packaging48 = Cooling/Gas Heat RTU0=Standardwith Puron refrigerant1=LTL3= / Model4=LTL& = WeatherMaker SeriesElectrical OptionsHeat SizeA=NoneD=LowheatC = N on --- f u sed d iscE = Medium heatD=ThruthebaseF=HighheatF = Non---fused & thru the baseL=LowNOx,lowheatM=LowNOx, medium heatService OptionsN=LowNOx,highheat0=NoneS = Stainless steel, low heat1 = Un---powered convenience outletR = Stainless steel, medium heat2 = Powered convenience outletT = Stainless steel, high heat3 = Hinged Panels4 = Hinged Panels Un---powered System Options5 = Hinged Panels Powered = Standard 1---stage coolingB = Standard 1---stage cooling models withHu mid i --- MiZ er (04 --- 07 mod els on ly )

7 Intake / Exhaust OptionsD = Stan d ard 2 --- stag e coolin g mod els 08 --- 16A=NoneE = 2 --- stag e coolin g 08 --- 16 with Al/C uB=Tempeconow/baroreliefcondenser coil and Humidi---MiZerF = Enthalpy econo w/ baro reliefK = 2 --- Position d amp erCooling Tons04 = 3 Ton08 = TonBase Unit Controls05 = 4 Ton09 = Ton0 = Electromechanical06 = 5 Ton12 = 10 Ton1 = PremierLink DDC controller07 = 6 Ton14 = Ton2 = RTU Open multi protocol controller16 = 15 TonDesign RevSensor OptionsFactory assignedA=NoneB = RA smoke detectorVoltageC = SA smoke detector1 = 575/3/605 = 208---230/3/60D=RA&SAsmokedetector3 = 208---230/1/60*6 = 460/3/60E=CO2sensorF = RA smoke detector & CO2 Models w/Round Tube Plate Fin (RTPF) condenser coilsG = SA smoke detector & CO2( O u td o o r --- I n d o o r --- H a i l G u a r d )H=RA&SAsmokedetector&CO2A = Al/Cu --- Al/CuB = P recoat Al/C u --- Al/C uIndoor Fan OptionsC = E coat Al/C u --- Al/C u1 = Standard static optionD=EcoatAl/Cu---EcoatAl/Cu2 = Medium static optionE = C u /C u --- Al/C u3 = High static optionF = Cu/Cu --- Cu/CuC = High Static Option w/High Efficiency Motor (Size 16 only)

8 M = Al/C u --- Al/C u --- L ou vered Hail Gu ard sN = P recoat Al/C u --- Al/C u --- L ou vered Hail Gu ard sP = E coat Al/C u --- Al/C u --- L ou vered Hail Gu ard sQ = E coat Al/C u --- E coat Al/C u --- L ou vered Hail Gu ard sSee page 5 for further details on available factory installedR = Cu/Cu --- Al/Cu --- Louvered Hail Guardsoptions by voltage and other important = Cu/Cu --- Cu/Cu --- Louvered Hail GuardsModels w/All aluminum, Novation condenser coils*On single phase (---3 voltage code) models, the following are not( O u td o o r --- I n d o o r --- H a i l G u a r d )availab le as a f actor --- in stalled op tion :G = Al/Al --- Al/C u--- Hu mid i --- MiZ erH = Al/Al --- C u /C u--- C oated C oils or C U Fin C oilsJ = Al/Al --- E --- coat Al/C u--- L ou vered Hail Gu ard sK = E --- coat Al/Al --- Al/C u--- Econ omizer or 2 Position Damp erL = E --- coat Al/Al --- E --- coat Al/C u--- Powered 115 Volt C on ven ien ce O u tletT = Al/Al --- Al/C u --- L ou vered Hail Gu ard sU = Al/Al --- C u /C u --- L ou vered Hail Gu ard sV = Al/Al --- E --- coat Al/C u --- L ou vered Hail Gu ard sW = E --- coat Al/Al --- Al/C u --- L ou vered Hail Gu ard sX = E --- coat Al/Al --- E --- coat Al/C u --- L ou vered Hail Gu ard s48TC5 Table 1 FACTORY--INSTALLED OPTIONS AND FIELD--INSTALLED ACCESSORIESCATEGORYITEMFACTORYINSTALLEDO PTIONFIELDINSTALLEDACCESSORYC

9 AbinetThru---the---base electrical or gas---line connectionsXXSupply Duct Cover (16 size only)XCalifornia Seismic Compliant LabelingXHinged Access PanelsXCoil OptionsCu/Cu indoor and/or outdoor coils1, 6 XPre---coated outdoor coils1, 6 XPremium, E---coated outdoor coils1, 6 XHumidity ControlHumidi---MiZer Adaptive Dehumidification System6 XCondenser ProtectionCondenser coil hail guard (louvered design)6 XXControlsThermostats, temperature sensors, and subbasesXPremierLink DDC communicating controllerXXRTU Open---protocol controllerXSmoke detector (supply and/or return air)XTime Guard II compressor delay control circuitXPhase MonitorXEconomizers& Outdoor AirDampersEconoMi$ertIV (for electro---mechanical controlled RTUs)6 XXEconoMi$ert2 (for DDC controlled RTUs)6 XXMotorized 2 position outdoor air damper6 XXManual outdoor air damper (25% and 50%)XBarometric relief2 XXPower exhaustXEconomizer Sensors&IAQ DevicesSingle dry bulb temperature sensors3 XXDifferential dry bulb temperature sensors3 XSingle enthalpy sensors3 XXDifferential enthalpy sensors3 XWall or duct mounted CO2sensor3 XUnit mounted CO2sensor3 XGas HeatPropane conversion kitXStainless steel heat exchangerXHigh altitude conversion kitXFlue ShieldXFlue Discharge DeflectorXIndoor Motor & DriveMultiple motor and drive packagesXLow AmbientControlWinter start kit4 XMotormaster head pressure controller4 XPowerOptionsConvenience outlet (powered)6 XConvenience outlet (un---powered)

10 XNon---fused disconnect5 XDisconnect Switch Bracket (16 size only)XRoof CurbsRoof curb 14---in (356mm)XRoof curb 24---in (610mm)XNOTES:1. Novation coated coils only available with Included with Sensors used to optimize economizer See application data for Available on units with MOCP s of 80 amps or Not available as factory installed option on single phase (208/230/1/60) models. Use field---installed accessory where OPTIONS AND/OR ACCESSORIESE conomizer (dry--bulb or enthalpy)Economizers save money. They bring in fresh, outside airfor ventilation; and providecool, outsideair to cool yourbuilding. This is the preferred method of low ambientcooling. When coupled to CO2sensors, economizers canprovide even more savings by coupling the ventilation airto only that amount are available, installed and tested by thefactory, with either enthalpy or dry--bulb temperatureinputs.