Transcription of Product Data - Carrier
1 Specifications subject to change without notice. Fig. 1 Sizes 09K - 36 KNOTE: Images are for illustration purposes only. Actual models may differ OF CONTENTSPAGEINDUSTRY LEADING FEATURES / BENEFITS .. 1 MODEL NUMBER NOMENCLATURE .. 3 STANDARD FEATURES AND ACCESSORIES .. 4 DIMENSIONS .. 8 SPECIFICATIONS .. 10 PERFORMANCE .. 11 COOLING PERFORMANCE - HIGH WALL .. 13 HEATING PERFORMANCE - HIGH 15 COOLING PERFORMANCE - CASSETTE .. 17 HEATING PERFORMANCE - CASSETTE .. 18 COOLING PERFORMANCE - 19 HEATING PERFORMANCE - DUCTED .. 20 COOLING PERFORMANCE - CONSOLE .. 21 HEATING PERFORMANCE - 22 COOLING PERFORMANCE - AIR HANDLER .. 23 HEATING PERFORMANCE- AIR 23 APPLICATION DATA .. 24 WIRING .. 25 AIRFLOW DATA .. 26 SOUND PRESSURE .. 26 ELECTRICAL DATA .. 27 CONNECTION DIAGRAMS .. 28 WIRING 29 GUIDE 31 INDUSTRY LEADING FEATURES / BENEFITSA PERFECT BALANCE BETWEEN BUDGET LIMITS, ENERGY SAVINGS AND 38 MARB series ductless systems are a matched combination of an outdoor condensing unit and an indoor fan coil unit connected only by refrigerant tubing and ductless system permits creative solutions to design problems such as: Add-ons to current space (an office or family room addition) Special space requirements When changes in the load cannot be handled by the existing system When adding air conditioning to spaces that are heated by hydronic or electric heat and have no ductwork Historical renovations or any application where preserving the look of the original structure is ideal compliment to your ducted system when it is impractical or prohibitively expensive to use compact indoor fan coil units take up very little space in the room and do not obstruct windows.
2 The fan coils are attractively styled to blend with most room decors. Advanced system components incorporate innovative technology to provide reliable cooling performance at low sound Data38 MARBO utdoor Unit Single Zone Ductless SystemSizes 09 to 362 Specifications subject to change without notice. 38 MARB-01 PDInverter TechnologyThe inverter driven compressor is designed to run at various inputpower frequencies (Hz) which controls the compressor s motor Temperature The control package, including the inverter,monitors the outdoor and indoor temperatures as they relate to theselected indoor set point and adjusts the compressor speed to matchthe load and keep the system operating continuously rather thancycling and creating temperature swings. This translates to highercomfort levels for the Pull Down/Warm-Up Comfort is increased by the inverter system s ability to ramp up the compressor speed enabling the system to reach the user selected room temperature set point Control Running the system for longer periods andcontinuously varying the compressor speed enhances the Room ComfortMaximum comfort is provided because each space can be controlled individually based on the usage Sound LevelsWhen noise is a concern, ductless systems are the answer.
3 The indoor units are whisper quiet. There are no compressors indoors, either in the conditioned space or directly over it, and there is none of the noise usually generated by air being forced through the sound ordinances and proximity to neighbors demand quiet operation, the 38 MARB unit is the right choice. With the inverter technology, these units run at lower speeds most of the time resulting in reduced sound Technology Enhanced Economical OperationDuctless systems are inherently economical to operate. Individual rooms are heated or cooled only when required, and since the air isdelivered directly to the space, there is no need to use additionalenergy to move the air in the ductwork. This economical operationis enhanced further when the inverter system output matches the load resulting in a more efficient ControlsThe systems have microprocessor-based controls to provide the ultimate in comfort and efficiency. The user friendly wired and wireless remote controls provide the interface between the user and the OperationIf security is an issue, outdoor and indoor units are connected onlyby refrigerant piping and wiring to prevent intruders from crawlingthrough ductwork or wall openings.
4 In addition, since the 38 MARB can be installed close to an outside wall, coils are protected from vandals and severe InstallationThis compact ductless system is simple to install. Only wires andpiping need to run between the indoor and outdoor units. These units are fast and easy to install ensuring minimal disruption to customers in homes or the workplace. This makes the 38 MARB systems the equipment of choice for retrofit Servicing and MaintenanceRemoving the top panel of the outdoor unit provides immediateaccess to the control compartment, providing the service technicianaccess to the diagnostic LEDs to facilitate the troubleshootingprocess. In addition, the draw-thru design of the outdoor unit means that dirt accumulates on the outside surface of the coil. Coils can be cleaned quickly from the inside using a pressure hose and the indoor units, service and maintenance expense is reduceddue to the permanent easy to clean filters. Also, error codes are displayed on the front panel to alert the user to certain ReliabilityDuctless system indoor and outdoor units are designed to provideyears of trouble-free operation.
5 Both the indoor and outdoor units are well protected. Whenever the microprocessor detects abnormal conditions, the unit stops and an error code systems provide additional reliability due to the soft refers to the ability of the inverter to start the compressor motor using reduced voltage and reduced current. This feature is beneficial from an electrical standpoint (eliminates current spikes) as well as an overall reliability standpoint due to reduced stress on all associated system ListingsAll systems are listed with AHRI (Air conditioning, Heating, andRefrigeration Institute) and are ETL certified per UL Specifications subject to change without notice. 3 MODEL NUMBER NOMENCLATUREOUTDOOR UNIT38 MARBQ36--338 = OUTDOOR UNITMA = MODELVOLTAGE1=115-1-603=208/230-1-60 SYSTEM TYPER = OUTDOORMAXIMUM NUMBER OF FAN COIL UNITS THAT CAN BE CONNECTED TO THE OUTDOOR UNITB = 1:1 UNIT TYPEQ = HEAT PUMPNOMINAL CAPACITY09 - 3/4 TON12 - 1 TON18 - 1-1/2 TONS24 - 2 TONS30 - 2-1/2 TONS36 - 3 TONSMAJOR SERIESUse of the AHRI CertifiedTM Mark indicates amanufacturer s participation in the program For verification of certification for individual products, go to 4 Specifications subject to change without notice.
6 38 MARB-01 PDSTANDARD FEATURES AND ACCESSORIESL egendS - StandardA - AccessoryAccessoriesNOTE: The base pan is built in with multiple holes for proper draining during the defrost process. For applications where it is required to seal these holes, and re-direct the condensate drain, rubber plugs are available through UnitsCrankcase UnitThe crankcase heater is standard on all unit sizes. Heater clamps mustbe placed around the compressor oil pan HeaterThe base pan heater is standard on all unit sizes. Ease Of InstallationLow Voltage ControlsSComfort FeaturesMicroprocessor ControlsSAuto Restart FunctionSAuto ChangeoverSEnergy Saving FeaturesInverter Driven CompressorS46 F Heating Mode (Heating Setback)SSafety And Reliability3 Minute Time Delay For CompressorSHigh Compressor Discharge TemperatureSLow Voltage ProtectionSCompressor Overload ProtectionSCompressor Over Current ProtectionS IPM Module ProtectionSCondenser High Temp Protection in Cooling ModeSAluminum Hydrophilic pre-coated finsSEase Of Service And MaintenanceDiagnosticsSLiquid Line Pressure TapsSApplication FlexibilityCrankcase HeaterSBase pan HeaterSOutdoor Unit Model NumberBase Pan Base RubberPlugs RCD Part per Unit38 MARBQ12AA138 MARBQ09AA338 MARBQ12AA312600801A000771338 MARBQ18AA312600801A000772538 MARBQ24AA338 MARBQ30AA338 MARBQ36AA312600801A00117538 MARB-01PD Specifications subject to change without notice.
7 5 DIMENSIONSFig. 2 Outdoor Unit UNIT SIZES12K9K12K18K24K30K36 KVOLTAGES115V208/230V208/230V208/230V208 /230V208/230V208/230 VHEIGHT (H)IN (MM) (555) (554) (554) (673) (810) (810) (810)WIDTH (W)IN (MM) (765) (805) (805) (890) (946) (946) (946)DEPTH (D)IN (MM) (303)) (330) (330) (342) (410) (410) (410)L1IN (MM) (452) (511) (511) (663) (673) (673) (673)L2IN (MM) (286) (317) (317) (347) (403) (403) (403)OPERATING WEIGHTLBS (KG) ( ) ( ) ( ) ( ) (61) ( ) ( )WDL2HL1 Air outletAir inlet6 Specifications subject to change without notice. 38 MARB-01 PDDIMENSIONS (CONT) Fig. 3 Dimension Size 12K (115V)Fig. 4 Dimension Sizes 09K-12K38 MARB-01PD Specifications subject to change without notice.
8 7 DIMENSIONS (CONT)Fig. 5 Dimension Size 18 KFig. 6 Dimension Sizes 24K, 30K, and 36K8 Specifications subject to change without notice. 38 MARB-01 PDCLEARANCESFig. 7 Clearances NOTE: The outdoor unit must be mounted at least 2in (50mm) above the maximum anticipated snow 8 Clearances for multiple unitsUNITMINIMUM VALUEIN. (MM)A24 (610)B24 (610)C24 (610)D4 (101)E4 (101)DBAECAir inletAir outlet59in (150cm)or more whenfacing each other Blowing into the air-inlet of other condenser shall be (60cm)or more59in (150cm)or more on amultiple parallelunit arrangement24in (61cm) or more on a single parallel unit arrangement19in (48cm) or more on a multiple parallel unit arrangement 4in (10cm) or more on a singleparallel unit arrangement (25cm) or more for proper airflow24in (61cm) or more is recommendedfor (25cm) or more forproper airflow 24in(61cm)or more is recommendedfor service38 MARB-01PD Specifications subject to change without notice.
9 9 SPECIFICATIONS* Condensing unit above or below the indoor unitSystemSize1291218243036 Outdoor Model38 MARBQ12AA138 MARBQ09AA338 MARBQ12AA338 MARBQ18AA338 MARBQ24AA338 MARBQ30AA338 MARBQ36AA3 ElectricalVoltage, Phase, CycleV/Ph/Hz115-1-60208/230-1-60208/230- 1-60208/230-1-60208/230-1-60208/230-1-60 208 252328 MOCP - Fuse RangeCooling Outdoor DB Min - Max F( C)-22~130 (30-55)-22~130 (30-55)-22~130 (30-55)-22~130 (30-55)-22~130 (30-55)-22~130 (30-55)-22~130 (30-55)Heating Outdoor DB Min - Max F( C)-22~86 (-30~30)-22~86 (-30~30)-22~86 (-30~30)-22~86 (-30~30)-22~86 (-30~30)-22~86 (-30~30)-22~86 (-30~30)PipingTotal piping Lengthft (m)82 (25)82 (25)82 (25)98 (30)164 (50)164 (50)213 (65) piping Lift*ft (m)32 (10)32 (10)32 (10)65 (20)82 (25)82 (25)98 (30)Pipe Connection Size - Liquidin (mm)1/4 ( )1/4 ( )1/4 ( )1/4 ( )3/8 ( )3/8 ( )3/8 ( )Pipe Connection Size - Suctionin (mm)1/2 ( )3/8 ( )1/2 ( )1/2 ( )5/8 (16)5/8 (16)5/8 (16)RefrigerantRefrigerant TypeR410AR410AR410AR410AR410AR410AR410 ACharge lbs (kg) ( ) ( ) ( ) ( ) ( ) ( ) ( )Metering DeviceEEVEEVEEVEEVEEVEEVEEVO utdoor CoilFace AreaSq.
10 Rows2222233 Fins per inch21202020201818 Circuits4446 466 CompressorTypeRotary InverterRotary InverterRotary InverterRotary InverterRotary InverterRotary InverterRotary InverterModelKSK103D33 UEZ3 KTN110D42 UFZKTN110D42 UFZKTM240D43 UKTKTM240D43 UKTKTF250D22 UMTKTF250D22 UMTOil TypeVG74VG74VG74VG74VG74VG74VG74 Oil ChargeFl. OutdoorUnit Widthin (mm) (765) (805) (805) (890) (946) (946) (946)Unit Heightin (mm) (555) (554) (554) (673) (810) (810) (810)Unit Depthin (mm) (303) (330) (330) (342) (410) (410) (410)Net Weightlbs (kg) ( ) ( ) ( ) ( ) (61) ( ) ( )AirflowCFM7941,3241,3241,7652,2352,2352 ,235 Sound PressuredB(A) Specifications subject to change without notice. 38 MARB-01 PDCOMPATIBILITY * Denotes units that are not compatible with any outdoor unit listed in the Compatibility TableINDOOR UNITOUTDOOR UNIT38 MAQB12R--138 MAQB09R--338 MAQB12R--338 MAQB18R--338 MAQB24R--338 MAQB30R--338 MAQB36R--338 MARBQ12AA138 MARBQ09AA338 MARBQ12AA338 MARBQ18AA338 MARBQ24AA338 MARBQ30AA338 MARBQ36AA3 High Wall40 MAQB12B--140 MAHBQ12XA1 40 MAQB09B--340 MAHBQ09XA3 40 MAQB12B--340 MAHBQ12XA3 40 MAQB18B--340 MAHBQ18XA3 40 MAQB24B--340 MAHBQ24XA3 40 MAQB30B--340 MAHBQ30XA3 40 MAQB36B--340 MAHBQ36XA3 Cassette40 MBCQ09---3 40 MBCQ12---3 40 MBCQ18---3 40 MBCQ24---3 40 MBCQ36---3*40 MBCQ48---3*Ducted40 MBDQ09---3 40 MBDQ12---3 40 MBDQ18---3 40 MBDQ24---3 40 MBDQ36---3*40 MBDQ48---3*40 MBDQ58---3*Console40 MBFQ12---3 40 MBFQ18---3 40 MBFQ24---3 40 MBFQ36---3*40 MBFQ48---3*40 MBFQ58---3*38 MARB-01PD