FE4A, FE5A Infinityr SeriesCommunicating Variable-Speed Fan CoilPuronr RefrigerantSizes 002 thru 006 Product DataPREMIUM ENVIRONMENTALLYRESPONSIBLE FAN COILThe latest in technology makes the FE4A and FE5A fan coilmodels the most advanced air handlers available. With attention toquiet, efficient, and comfortable operation, Carrier has developed anew benchmark for homeowner comfort and ease of FE4A and FE5A utilize the Infinityr Control as a requiredaccessory to enable state of the art smart diagnostics enables faster troubleshooting, providing ease of service andrepair. The FE4A and FE5A also provide a 4 wire hook up withmatching outdoor unit and the Infinityr Control. This makesinstallation simpler and a lot quicker than with conventional fancoils. The FE4A and FE5A have advanced technology that allowsthe fan coil to self configure with a matching outdoor unit and theInfinityt Control, cutting down on installation FE4A and FE5A feature Puronr refrigerant, the chlorine freealternate that is the future for the residential heating and coolingindustry.

to environmental safety, these systems are 30 to 40% more efficient than standard heating and cooling systems, thereby combining excellence in efficiency and environmental sustainability. The FE4A and FE5A provide these benefits due to Carrier’s command of Electronically Commutating Motor (ECM) technology.

Tags:

  Safety

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Data - Carrier

1 FE4A, FE5A Infinityr SeriesCommunicating Variable-Speed Fan CoilPuronr RefrigerantSizes 002 thru 006 Product DataPREMIUM ENVIRONMENTALLYRESPONSIBLE FAN COILThe latest in technology makes the FE4A and FE5A fan coilmodels the most advanced air handlers available. With attention toquiet, efficient, and comfortable operation, Carrier has developed anew benchmark for homeowner comfort and ease of FE4A and FE5A utilize the Infinityr Control as a requiredaccessory to enable state of the art smart diagnostics enables faster troubleshooting, providing ease of service andrepair. The FE4A and FE5A also provide a 4 wire hook up withmatching outdoor unit and the Infinityr Control. This makesinstallation simpler and a lot quicker than with conventional fancoils. The FE4A and FE5A have advanced technology that allowsthe fan coil to self configure with a matching outdoor unit and theInfinityt Control, cutting down on installation FE4A and FE5A feature Puronr refrigerant, the chlorine freealternate that is the future for the residential heating and coolingindustry.

2 The FE4A and FE5A using PuronR refrigerant maximizeperformance for environmentally responsible systems. In additionto environmental safety , these systems are 30 to 40% more efficientthan standard heating and cooling systems, thereby combiningexcellence in efficiency and environmental FE4A and FE5A provide these benefits due to Carrier scommand of Electronically Commutating Motor (ECM)technology. These motors are extremely efficient at all speeds, andenable the FE4A and FE5A to operate at the correct speed todeliver airflow precisely, ensuring proper performance across awide range of duct static pressures. This adaptive efficiency alsomakes installation quality easier to achieve for today s s command of ECM technology may be most evident in thecomfort advantages that an ECM can deliver. For true comfort, thehomeowner can achieve command of both temperature andhumidity in cooling and heating feature which sets the FE4A and FE5A apart is thefactory installed TXV, which enhances efficiency and providescompressor protecting operation at all recommended tubing, louvered aluminum fins, and the large face areasof the FE4A and FE5A refrigerant coils also provide superiorefficiency, for high SEER and HSPF leads the way in condensate control, a hallmark of thesemultipoise fan coils.

3 All of these featured components are protectedwithin a rugged, pre painted metal cabinet lined with super thick,high density insulation. For neat, high quality installations, theunit exterior features sweat refrigerant connections for simple leakfree performance, and multiple electrical entry for both high andlow voltage at the factory compliant with low leak requirements of less than 2% cabinet leakage rate at inches and leakage rate at inches when tested in accordance with ASHRAE 193 DiagnosticsSSelf configuring (ease of installation)SEasier troubleshooting, providing faster service and repairSEnergy Tracking capability with the Infinityr Series Wall Control.(Energy Tracking has the ability to monitor and estimate the energy consumption of your Infinityr system.)Environmentally Responsible Refrigerant TechnologySPuronR refrigerant the chlorine free, non ozone depleting refrigerantSThermostatic Expansion Valve (TXV) designed to maximize performance with PuronR refrigerantEnergy Efficient OperationSElectronically Commutated Motor (ECM)

4 Operates efficiently at all speedsSMaximizes efficiency of heating and cooling systemsSUltra low power consumption during fan only operationComfort ControlSWarm, comfortable heating air temperaturesSUnmatched humidity controlAirflow and Sound TechnologySLogarithmic spiral blower housings for high blower efficiency and quiet operationSDiffuser air discharge section for high airflow efficiency and quiet, smooth operationSHigh duct static capabilitySDesign meets stringent regulations for cabinet air leakage of less than 2% when tested at inches , and cabinet air leakage lessthan at inches when tested in accordance with ASHRAE 193 Control and Disposal TechnologySMinimal standing water less microbial growth for improved IAQ and reduced condensate line clogging and related condensate leakageSCondensate fittings relocated away from turbulent airflow patterns at the blower entrance for improved condensate control performanceSOverflow feature for slope coil units allows condensate to exit the unit without damage to Product under clogged primary and secondaryline conditionsSTested for condensate disposal at conditions much more severe than those required by ARISP rimary and secondary drain connections to comply with HUDSAll pans constructed of an injection molded glass filled polycarbonate engineered resin material, with brass drain connectionsSHigh density.

5 Super thick cabinetry insulation with vapor barrierSPre painted galvanized sheet metal cabinetHeat Transfer TechnologySGrooved tubingSLanced sine wave aluminum finsSDiscreet refined counterflow refrigerant circuitrySBi flow hard shutoff TXV metering deviceQuality Assisting, Ease of Installation and Service FeaturesSEasy 4 wire hook up: convenient and reduces installation unit is multipoiseSFE5A unit is upflow/downflow only (single drain pan).SProvision made for suspending from roof or ceiling jointsSModular cabinet on sizes 003 through 006 SSweat connections for leak free serviceSMultiple electrical entry for application flexibility (high and low voltage)SLow voltage terminal strip, to safely hold connections within the cabinetSCabinet construction features innovations designed to prevent cabinet sweatingControls and Electrical FeaturesSEasy plug connection provided for quick installation of accessory heater packagesS40VA 208/230v transformerSReplaceable 3 amp blade type auto fuse protects against transformer secondary shortFilter FeaturesSFactory supplied filterSCleanable polyester filter mediaSFilter springs out for easy access no tools requiredSNewly improved filter rack area filter door insulation added for an improved air seal3 MODEL NUMBER NOMENCLATURE123456789101112FE4 ANB002000 Coil TypeProductT00 = Tin-platedF = Fan Coil000 = CopperL00 = AluminumTypeE = Infinityr, VS, Puronr RefrigerantCapacity002 = 18-36,000 Position003 = 24-42,0004 = Multi-poise004 = 24-42,0005 = Upflow / Downflow005 = 30-48,000006 = 36-60.

6 000 SeriesACabinet / InsulationB = ModularElectricalF = Single pieceN = 208/230v, 1ph-60 HzUse of the AHRI CertifiedTM Mark indicates amanufacturer s participation in the program For verification of certification for individual products, go to 4004 -004 -DIMENSIONSUNITSIZEABCDEH*inmminmminmmin .mminmminmmFE4A00242-11/16108417-5/84481 5-3/440015-5/839710-3/4273 FE4A00353-7/16135721-1/853719-1/448919-1 /848619-3/16487 FE4A003*53-7/16135721-1/853719-1/448919- 1/848619-3/1648728-5/16719FE4A00553-7/16 135721-1/853719-1/448919-1/848619-1/2495 FE4A005*53-7/16135721-1/853719-1/448919- 1/848619-1/249528-5/16719FE4A006*59-3/16 150324-11/1662722-3/457822-11/1657625-1/ 464134-1/16865FE5A004*59-3/16150324-11/1 662722-3/457822-11/1657625-1/464134-1/16 865* Modular Cabinet5 DIMENSIONSUNITSIZEFGCOIL CONFIGURATIONSHIPPING WEIGHT inmminmmSlope A lb / kgFE4A00218-9/1647218-1/4464 Ye s135 / 61FE4A00326-15/1668427-1/2699Ye s 150 / 68FE4A003*26-15/1668427-1/2699Ye s 150 / 68FE4A00527-1/469226-15/16684 Ye s172 / 78FE4A005*27-1/469226-15/16684 Ye s172 / 78FE4A006*32-15/1683732-5/8829 Ye s207 / 94FE5A004*32-15/1683732-5/8829 Ye s200 / 91* Modular Cabinet6 PHYSICAL DATAORDERING HEAT(kW)NOMINALCOOLING CA PACITY(BTUH)

7 DIMENSIONSSHIPPINGWEIGHTlb / kgHeightWidthDepthFE4 ANF002000FE4 ANF002T00FE4 ANF002L005, 8, 9, 10, 15, 2018,000to36,00042-11/16-in1084 mm17-5/8-in 448mm22-1/16-in560 mm135 lb61 kgFE4 ANF003000FE4AN(B,F)003T00FE4AN(B,F)003L0 05, 8, 9, 10, 15, 18, 2024,000to42,00053-7/16-in1357 mm21-1/8-in 537mm22-1/16-in560 mm150 lb68 kgFE4 ANF005000FE4AN(B,F)005T00FE4AN(B,F)005L0 05, 8, 9, 10, 15, 18, 20, 24, 3030,000to48,00053-7/16-in1357 mm21-1/8-in 537mm22-1/16-in560 mm172 lb78 kgFE4 ANB006000FE4 ANB006T00FE4 ANB006L008, 9, 10, 15, 18, 20, 24, 3036,000to60,00059-3/16-in1503 mm24-11/16-in627 mm22-1/16-in560 mm207 lb94 kgFE5 ANB004T00FE5 ANB004L005, 8, 9, 10, 15, 18, 2024,000to42,00059-3/16-in1503 mm24-11/16-in627 mm22-1/16-in560 mm200 lb91 kgSPECIFICATIONSMODELFE4 AFE5 ASIZE002003005006004 COILR efrigerant Metering DevicePuronR Refrigerant (R-410A) TXVTXV Size2 Ton3 Ton4 Ton5 Ton3 TonConfigurationASlopeAAARows / Area (Sq Ft) OUTDOOR UNIT SIZESN ominal Cooling , 2, , 32, , 3, , 3, , 43, , 4, 52, , 3, DischargeUpflow, Downflow, HorizontalUpflow, DownflowCFM/Ton (Nominal Clg/Htg)350+Motor HP (ECM)1/21/21/23/43/4 Filter21-1/2-in (546 mm) x16-3/8-in(417 mm)19-7/8-in(505 mm)19-7/8-in(505 mm)23-5/16-in(592 mm)23-5/16-in(592 mm)CABINET CONFIGURATION OPTIONS1-piece1-piece / Modular1-piece / ModularModularModular7 PERFORMANCE DATAAIRFLOW DELIVERY COOLING, HEATING, ELECTRIC HEATING MODESThe FE4 and FE5A fan coils will provide airflow at a rate that isrequested by the Integrated System User Interface during airconditioning or heat pump heating (without electric heat) nominal airflow for both heating and cooling modes is 350cfm/ton nominal size of the outdoor unit installed.

8 The airflowactually requested by the User Interface is modified by its internalalgorithms for zoning, comfort or efficiency concerns. Refer to thedocumentation for the User Interface for more information on howthe User Interface controls the fan coil. Safe operation of electricheaters requires airflow delivery at or above the minimum CFM forelectric heater application listed in the chart below. The fan coilwill adjust its airflow delivery to maintain safe airflow as operatingmode and staging conditions FAN COIL AIRFLOW DELIVERY CHART (CFM) ELECTRIC HEATING MODELSMODEL FE4 AOUTDOOR UNIT CAPACITY BTUHELECTRIC HEATER kW RANGE591015202430002 EMERGENCY18,00024,00030,00036,0006256256 5080097562562572587597567567577587597577 5 9009251025950 11251125 003 EMERGENCY24,00030,00036,00042,0006756758 0097511257008758759751125775875875102511 2585011001100115011501050115011501250135 0 005 EMERGENCY30,00036,00042,00048,0006758009 7511251305700875975112513057758751025112 5130585011001150115013051050115012501250 13501400 15001425 1600006 EMERGENCY36,00042,00048,00060,0001050105 0112513001625105010501125130016251050110 0115013001625105013501350135016251125135 01350150017501750 175017501750 17501750 MODEL FE5 AOUTDOOR UNIT CAPACITY BTUHELECTRIC HEATER kW RANGE591015202430004 EMERGENCY24,00030,00036,00042,0006759751 0501050112577597510501050112577597511001 1001150900 1125135013501125 13501350 Note 1: Emergency - Air conditioner with electric heater application, or emergency 2.

9 These airflows are minimum airflows as UL 3: Dashed entry indicates that the heater/fan coil/outdoor unit combination is not approved. Do not DUCT STATIC PRESSURE (in wc)SUPPLY STATIC PRESSURE (in wc)TOO HIGHRETURN STATICPRESSURE(DIFFICULT TO MAKE TRAP)ACCEPTABLE RANGEA07273 For satisfactory operation (specifically making dry secondary trap), subject fan coils must be installedwith duct systems which fall within the Acceptable Range illustrated RPM TABLEMODELSYSTEM SIZESCFMRANGEMINRPMFE4 ANF002018, 024, 030, 036150 - 1200300FE4AN(B,F)003024, 030, 036, 042200 - 1400285FE4AN(B,F)005030, 036, 042, 048250 - 1600275FE4 ANB006036, 042, 048, 060500 - 2000275FE5 ANB004024, 030, 036, 042500 - 1400275 MAXIMUM STATIC TABLEMODELAIRFLOWDELIVERYAVAILABLE STATICPRESSUREFE4 ANF002525 in wc700 in wc875 in wc1050 in wc1200 in wcFE4AN(B,F)003700 in wc875 in wc1050 in wc1225 in wc1400 in wcFE4AN(B,F)005875 in wc1050 in wc1225 in wc1400 in wc1600 in wcFE4 ANB0061050 in wc1225 in wc1400 in wc1750 in wc2000 in wcFE5 ANB004700 in wc875 in wc1050 in wc1225 in wc1400 in wc9 GROSS COOLING CAPACITIES (MBTUH)INDOOR COILAIRSATURATED TEMPERATURE LEAVING EVAPORATOR (_F / _C)35 / 240 / 445 / 750 / 1055 / 13 CFMEWBTCSHCBFTCSHCBFTCSHCBFTCSHCBFTCSHCB FFE4 ANF00250072 - Cubic Ft per MinuteEWB - Entering Wet Bulb (_F / _C)LWB - Leaving Wet Bulb (_F / _C)TC - Gross Cooling Capacity 1000 BtuhSHC - Gross Sensible Capacity 1000 BtuhBF - Bypass FactorMBH - 1000 BtuhNOTES: 1.

10 Contact manufacturer for cooling capacities at conditionsother than shown in Formulas:Leaving db = entering db -sensible heat x CFML eaving wb = wb corresponding to enthalpy of air leav ing coil (hlwb)hlwb = hewb -total capacity (Btuh) x CFMwhere hewb = enthalpy of air entering coil. Direct inter polation is permissible. Do not SHC is based on 80_F db temperature of air entering 80_F db, subtract (Correction Factor x CFM) fromSHC. Above 80_F db, add (Correction Factor x CFM) Bypass Factor = 0 indicates no psychometric bypass factor of next lower EWB for CORRECTION FACTORBYPASSFACTORENTERING AIR DRY-BULB TEMPERATURE (_F)7978777675 Under 758182838485 Over 85 Correction is Factor = x (1 - BF) x (db - 80)ESTIMATED SOUND POWER LEVEL (dBA)MODELSIZECONDITIONSOCTAVE BAND CENTER *Est. sound power levels have been derived using the method described in the 1987 ASHRAE HVAC Systems & Applications Handbook, chapter 52, p. PERFORMANCE CORRECTION FACTORSHEATER KWELEMENTSSTATIC PRESSURE CORRECTION (in wc)Sizes 002 005 Size 00600+.