159SC5 AComfort Series Single---Stage4 --- Way MultipoiseCondensing Gas FurnaceSeries 2 Product DataA11263 The 59SC5 Multipoise Comfort Series Condensing Gas Furnacefeatures energy efficiency of AFUE gas efficiency andworkhorse PSC blower gas furnace also features4-way multipoise installation flexibility, and is available in ninemodel sizes. The 59SC5 can be vented for direct vent/two-pipe,ventilated combustion air, or single-pipe applications. All unitsmeet California Air quality Management District emissionrequirements, are design certified in Canada, and are certified formobile/manufactured home FEATURESS4-way multipoise design for upflow, downflow or flexibility with a360-degree rotating than twelve different venting options, including optionalthrough-the-cabinet downflow and horizontal condensing furnace height 35 (889 mm) cabinet: shortenough for taller coils, but still allows enough room for Nitride Power HeattHot Surface primary heat condensing secondary heat corrosion-resistant prepainted steel cabinet withhemmed edges for ready for upflow combustion, single-pipe venting or ventilatedcombustion blower motor, single-speed inducer motor, and single-stagegas with SuperBrite for Twinning applications (040--1)

4-way multipoise installation flexibility, and is available in nine model sizes. The 59SC5 can be vented for direct vent/two-pipe, ventilated combustion air, or single-pipe applications. All units meet California Air Quality Management District emission requirements, are design certified in Canada, and are certified for mobile/manufactured home ...

Tags:

  Installation, Quality, Hvac

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Product Data - HVAC

1 159SC5 AComfort Series Single---Stage4 --- Way MultipoiseCondensing Gas FurnaceSeries 2 Product DataA11263 The 59SC5 Multipoise Comfort Series Condensing Gas Furnacefeatures energy efficiency of AFUE gas efficiency andworkhorse PSC blower gas furnace also features4-way multipoise installation flexibility, and is available in ninemodel sizes. The 59SC5 can be vented for direct vent/two-pipe,ventilated combustion air, or single-pipe applications. All unitsmeet California Air quality Management District emissionrequirements, are design certified in Canada, and are certified formobile/manufactured home FEATURESS4-way multipoise design for upflow, downflow or flexibility with a360-degree rotating than twelve different venting options, including optionalthrough-the-cabinet downflow and horizontal condensing furnace height 35 (889 mm) cabinet: shortenough for taller coils, but still allows enough room for Nitride Power HeattHot Surface primary heat condensing secondary heat corrosion-resistant prepainted steel cabinet withhemmed edges for ready for upflow combustion, single-pipe venting or ventilatedcombustion blower motor, single-speed inducer motor, and single-stagegas with SuperBrite for Twinning applications (040--12 through 120-20sizes, only).

2 SPropane convertible (Seeaccessory list).SApproved for Manufactured Housing/Mobile Home applications(except 140,000 Btuh input) with MHaccessory Air Purifier and Humidifier electrical installations may be eligible for consumer financingthrough the Retail Credit to leak 2% or less of nominal air conditioning CFMdelivered when pressurized to 1--in. water column with allpresent air inlets, air outlets, and condensate drain port(s) of the AHRI Certified TM Mark indicates amanufacturer s participation in the program. Forverification of certification for individual products,go to (IN.)RATED HEATINGOUTPUT HEATING )MOTOR HPSPEED TAPSHDW(BTUH)AFUECFM HeatingESP(in. ) , - , - , - , - , - , , - , , , Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate. Heating CFM at factory default blower motor heating tap --- External Static PressureFEATURES AND BENEFITSHYBRID HEATRDual Fuel system This system can providemore control over your monthly energy bills by automaticallyselecting the most economical method of heating.

3 With HYBRIDHEAT components, our system automatically switches between thegas furnace and the single--stage electric heat pump as outsidetemperatures change to maintain greater efficiency and comfortthan with any traditional single-source heating system. The heatpump also delivers high-efficiency cooling in the HeattIgniter Carrier s unique SiN igniter is not onlyphysically robust but it is also electrically robust. It is capable ofrunning at line voltage and does not require complex voltageregulators as do other brands. This unique feature further enhancesthe gas furnace reliability and continues Carrier s tradition oftechnology leadership and innovation in providing a reliable anddurable Heat Exchanger Design The aluminized steel, clamshell primary heat exchanger was re--engineered to achieve greaterefficiency out of a smaller size.

4 The first two passes of the heatexchanger are based on the current 80% Product , a design withmore than ten years of field-proven performance and innovations, paired with the continuation of a crimped,no-weld seam create an efficient, robust design for this condensing heat exchanger, a stainless steel fin and tubedesign, is positioned in the furnace to extract additional steel coupling box componentry between heat exchangershas exceptional corrosion resistance in both natural gas andpropane Multipoise Design One model for all applications there is no need to stock special downflow or horizontal modelswhen one unit will do it all. The new heat exchanger design allowsthese units to achieve the certified AFUE in all or Single-pipe Venting, or Optional VentilatedCombustion Air This furnace can be installed as a 2-pipe(Direct Vent) furnace, in an optional ventilated combustion airapplication, or in single-pipe, non-direct vent applications.

5 Thisprovides added flexibility to meet diverse installation Combustion System This furnace brings in combustionair from outside the furnace, which results in especially quietoperation. By sealing the entire combustion vestibule, the entirefurnace can be made quieter, not just the Burners The burners are specially designed andfinely tuned for smooth, quiet combustion and Closure Factory-installed for side return; easilyremovable for bottom return. The multi-use bottom closure canalso serve for roll-out protection in horizontal applications, and actas the bottom closure for the optional return air base Access Panel Switch Automatically shuts off 115-vpower to furnace whenever blower access panel is Registration Our furnaces are engineered andmanufactured under an ISO 9001 registered quality This furnace is CSA (AGA and CGA) designcertified for use with natural and propane gases.

6 The furnace isfactory--shipped for use with natural gas. A CSA listed gasconversion kit is required to convert furnace for use with propanegas. The efficiency is AHRI efficiency rating certified. This furnacemeets California Air quality Management District furnace should be sized to provide 100 percent of the designheating load requirement plus any margin that occurs because offurnace model size capacity increments. None of the furnacemodel sizes can be used if the heating load is 20,000 BTU orlower. Use Air Conditioning Contractors of America (Manual Jand S); American Society of Heating, Refrigerating, andAir-Conditioning Engineers; or other approved engineeringmethod to calculate heating load estimates and select the oversizing of the furnace may cause the furnace and/orvent to fail prematurely, customer discomfort and/or vent to follow these guidelines is considered faulty installationand/or misapplication of the furnace.

7 And resulting failure, damage,or repairs may impact warranty Capacity and Efficiency040-10040-12060-10060-14080-16 080-20100-14100-20120-20140-20 InputHighHeat(BTUH)40,00040,00060,00060, 00080,00080,000100,000100,000120,000140, 000 OutputHighHeat(BTUH)39,00039,00058,00058 ,00078,00078,00097,00097,000117,000135,0 00 Certified TemperatureRise Range F ( C)High Heat40 - 70(22 - 39)35 - 65(19 - 36)40 - 70(22 - 39)40 - 70(22 - 39)40 - 70(22 - 39)40 - 70(22 - 39)40 - 70(22 - 39)40 - 70(22 - 39)40 - 70(22 - 39)45 - 75(25 - 42)Airflow Capacity and Blower Data040-10040-12060-10060-14080-16080-20 100-14100-20120-20140-20 Rated External StaticPressure (in. ) Delivery@ Rated ESP (CFM)High Heat820100084098010401695151016802245217 5 Cooling905105011301420160019701545206521 052035 Cooling Capacity (tons)400 Motor TypePermanent Split Capacitor (PSC)Direct-Drive Motor Full Load Range500 -1150 Speed Selections4545554555 Blower Wheel Dia x x 711 x 811 x 711 x 811 x 811 x 1011 x 1011 x 1011 x 1111 x 11 Air Filtration SystemField SuppliedFilter Used for Certified Watt Data*KGAWF**06 UFRE lectrical Data040-10040-12060-10060-14080-16080-20 100-14100-20120-20140-20 Input VoltageVolts-Hertz-Phase115-60-1 Operating Voltage RangeMin-Max104-127 Maximum Input Wire SizeAWG14141414141214121212 Maximum Wire Length@ Minimum Wire SizeFeet39323832283035292929(M)( )( )( )( )( )( )( )( )( )( )Maximum Fuse/Ckt Bkr(Time-Delay Type Recom-mended)Amps15151515152015202020 Transformer Capacity (24vac output)

8 40 VAExternal Control VAControls040-10040-12060-10060-14080-16 080-20100-14100-20120-20140-20 Gas Connection Size1/2" - NPTB urners (Monoport)2233445567 Gas Valve (Redundant)ManufacturerWhite RogersMinimum Inlet Gas pressure (in. ) Inlet Gas pressure (in. ) DeviceSilicon NitrideLimit Control165180165180170200180180160155 Heating Blower Control (Heating Off-Delay)Adjustable: 90, 120, 150, 180 secondsCooling Blower Control (Time Delay Relay)90 secondsCommunication SystemnoneThermostat ConnectionsCom24V,R,W,G,YAccessory ConnectionsEAC (115vac); HUM (24vac)* See Accessory List for part numbers NUMBER NOMENCLATURE59TN6A060V17----14S - Single StageT - Two StageM - ModulatingC - ComfortP - PerformanceN - InfinityS - StandardE - Energy EfficientV - Variable Speed14 - 17 - 21 - 24 - 08 - 800 CFM10 - 1000 CFM12 - 1200 CFM14 - 1400 CFM16 - 1600 CFM18 - 1800 CFM20 - 2000 CFM22 - 2200 CFMF amilyMajor SeriesVoltageMinor Series1 - 2 Family3 Htg.

9 StagesTier45 Base SeriesHtg. - 9 Motor1011 - 12 Width13 Voltage14 Minor SeriesAirflow15 - 16040=40,000 BTU 060=60,000 BTU 080=80,000 BTU 100=100,000 BTU 120=120,000 BTU140=140,000 BTU Not all familes have these of Model Number0 - +90 AFUE2 - +92 AFUE3 - +93 AFUE5 - +95 AFUE6 - +96 AFUE7 - +97 AFUEA12373 FURNACE COMPONENTSRATING PLATE NOT SHOWN(LOCATED ON BLOWER DOOR)GAS VALVEMAIN LIMIT SWITCH(BEHIND GAS VALVE)REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN JUNCTIONBOX (IF REQUIRED, LOCATION MAY VARY)MEDIA CABINETOPERATING INSTRUCTIONSNOT SHOWN (LOCATED ONMAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE).FURNACECONTROLBOARDMANUAL RESETROLLOUT SWITCHFLAMESENSORMANUAL RESETROLLOUT SWITCHGAS BURNERHOT SURFACEIGNITERINDUCER MOTORASSEMBLYBLOWER ANDMOTORCAPACITOR/POWER CHOKE(IF USED)BLOWER DOORSAFETY SWITCHA1140859SC5A5 ACCESSORIESDESCRIPTIONPART NUMBER040---10060---10040---12060---1408 0---16080---20100-14100-20120-20140-20 Venting AccessoriesVent Kit - Through the CabinetKGADC0101 BVCDDDDDDDDDDVent Terminal - Concentric - 2 (51 mm)KGAVT0701 CVTSee Venting TablesVent Terminal - Concentric - 3 (76 mm)KGAVT0801 CVTVent Terminal Bracket - 2 (51 mm)KGAVT0101 BRAVent Terminal Bracket - 3 (76 mm)

10 KGAVT0201 BRAVent Kit --- Rubber CouplingKGAAC0101 RVCSee Venting TablesCondensate Drainage AccessoriesFreeze Protect Kit --- Trap HeaterKGAHT0201 CFPDDDDDDDDDDCPVC to PVC Drain Adapters - 1/2 CPVC to 3/4 PVCKGAAD0110 PVCDDDDDDDDDDH orizontal Trap Grommet - Direct VentKGACK0101 HCKAll DV HorizontalCondensate Neutralizer KitP908---0001 DDDDDDDDDDE xternal Trap KitKGAET0201 ETKDDDDDDDDDDD uctwork Adapter AccessoriesFurnace Base Kit for Combustible FloorsKGASB0201 ALLDDDDDDDDDDCoil Adapter Kits --- No OffsetKGADA0101 ALLDDDDDDDDDDCoil Adapter Kits --- Single OffsetKGADA0201 ALLDDDDDDDDDDCoil Adapter Kits --- Double OffsetKGADA0301 ALLDDDDDDDDDDR eturn Air Base (Upflow Applications) Air Base (Upflow Applications) Air Base (Upflow Applications) Air Base (Upflow Applications) Device Duct Adapters IAQ to 16 ReturnKGAAD0101 MEC20 x25 IAQ DevicesIAQ Device Duct Adapters IAQ to 16 ReturnKGAAD0201 MEC24 x25 IAQ DevicesGas Conversion AccessoriesMobile Home KitKGBMH0601 KITDDDDDDDDDGas Conversion Kit - Nat to LPKGBNP50011 SPDDDDDDDDDDGas Conversion Kit - LP to NatKGBPN42011 SPDDDDDDDDDDGasOrificeKit-#42(NatGas)LH3 2DB207 DDDDDDDDDDGasOrificeKit-#43(NatGas)LH32D B202 DDDDDDDDDDGasOrificeKit-#44(NatGas)LH32D B200 DDDDDDDDDDGasOrificeKit-#45(NatGas)LH32D B205 DDDDDDDDDDGasOrificeKit-#46(NatGas)LH32D B208 DDDDDDDDDDGasOrificeKit-#47(NatGas)LH32D B078 DDDDDDDDDDGasOrificeKit-#48(NatGas)LH32D B076 DDDDDDDDDDGas Orifice Kit - #54 (LP)LH32DB203 DDDDDDDDDDGas Orifice Kit - #55 (LP)LH32DB201 DDDDDDDDDDGas Orifice Kit - #56 (LP)LH32DB206 DDDDDDDDDDGas Orifice Kit - (LP)LH32DB209 DDDDDDDDDDGas Orifice Kit - (LP)