Example: biology

Product Data Sheet - Owens Corning

AttiCat Expanding Blown-inPINK FIBERGLAS InsulationProduct Data SheetAttiCat Expanding Blown-In PINK FIBERGLAS Insulation is designed for application in attics of new and existing AttiCat PINK FIBERGLAS Insulation is manufactured in accordance with ASTM C764 Type I (pneumatic application). R-values are determined in accordance with ASTM C687. In accordance with ASTM E136. Is considered noncombustible by the model building codes when tested. The surface burning characteristics of this Product have been determined in accordance with:ULC S E 84*Flame Spread00 Smoke Developed00 AttiCat PINK FIBERGLAS Insulation is:- Noncorrosive (per ASTM C764, section )- Does not absorb moisture (per ASTM C1104)- Does not support mold growth (per ASTM C1338) Conforms to the quality standards of the State of California.

117.4 22 2 x 4 2 x 6 2 x 8 98.1 100.6 103.2 96.7 98.3 100.0 26 2 x 4 2 x 6 2 x 8 82.5 ... 2 x 6 2 x 8 40.3 40.8 41.3 40.0 40.3 40.7 60 2 x 4 2 x 6 2 x 8 31.9 32.2 32.6 31.8 32.0 32.2 Disclaimer of Liability Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient’s sole risk ...

Tags:

  Technical

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Product Data Sheet - Owens Corning

1 AttiCat Expanding Blown-inPINK FIBERGLAS InsulationProduct Data SheetAttiCat Expanding Blown-In PINK FIBERGLAS Insulation is designed for application in attics of new and existing AttiCat PINK FIBERGLAS Insulation is manufactured in accordance with ASTM C764 Type I (pneumatic application). R-values are determined in accordance with ASTM C687. In accordance with ASTM E136. Is considered noncombustible by the model building codes when tested. The surface burning characteristics of this Product have been determined in accordance with:ULC S E 84*Flame Spread00 Smoke Developed00 AttiCat PINK FIBERGLAS Insulation is:- Noncorrosive (per ASTM C764, section )- Does not absorb moisture (per ASTM C1104)- Does not support mold growth (per ASTM C1338) Conforms to the quality standards of the State of California.

2 Meets requirements of Minnesota Insulation Standards ProgramThermal PerformanceStated R-value is achieved by installing the minimum required number of bags per 1,000 net sq. ft. at a thickness not less than the label minimum thickness and minimum sq. ft. weight. Failure by the installer to provide both the required number of bags and at least the minimum thickness will result in lower insulation insulation varies in thermal performance due to factors such as mean temperature, settlement, convection, moisture absorption and installation variation. Convection in fi ber glass loosefi ll insulation installed in open attics can reduce its thermal performance at extreme winter temperatures during the heating season. AttiCat PINK FIBERGLAS Insulation has been designed to anticipate this phenomenon and the labeled R-value refl ects the average performance over the winter heating season.

3 The dollar impact to a homeowner s annual heating cost from loosefi ll convection is estimated to be minimal, if any, when compared to labeled Specifi cationsOwens Corning does not recommend or approve blending or adding additional materials or adhesives to this Product during installation. Owens Corning will accept no responsibility or liability when the Product is not installed in accordance with the Product label and installation instructions. Owens Corning recommends and provides instructions for installing AttiCat PINK FIBERGLAS Insulation from the outside of exterior sidewalls. You may also install it from the inside, however, it is important to note that drill and fi ll installation from the inside requires a strong working knowledge of construction and framing principles, texture matching and other variables.

4 Please consult a professional contractor to perform this job, if you do not have this expertise.*This standard is used to measure and describe the response of materials, products, or assemblies to heat and fl ame under controlled conditions, but does not by itself incorporate all factors required for fi re-hazard or fi re-risk assessment of the materials, products, or assemblies under actual fi re conditions. However, the results of these tests may be used as elements of a fi re risk assessment that takes into account all of the factors per tinent to an assessment of the fi re hazard of a par ticular end use. Values are repor ted to the nearest fi ve (5) Expanding Blown-In PINK FIBERGLAS InsulationNominal Bag Weight ValueBags per 1000 Sq.

5 Net Coverage, Sq. Weight/Sq. Ft. Minimum Thickness, inchesMinimum Settled Thickness, Inches Data SheetAttiCat Expanding Blown-inPINK FIBERGLAS InsulationFire Hazard:To prevent fi re or overheating of recessed light fi xtures or similar electrical devices, do not inuslate on top of or within 3 inches of such devices unless they are specifi cally approved to be covered by insulation. Do not place insulation in air spaces surrounding metal fl ues, chimneys, or fi replaces. Provide minimum clearances specifi ed in NFPA-31, NFPA-54, or NFPA-211, or as required by local building codes. In Canada, maintain building, electrical, gas and oil safety code required clearances between the insulation and heat emitting devices, such as fuel burning appliances, chimneys, pipes, ducts and vents to these appliances (at least 50 mm) and recessed light fi xtures (at least 75 mm).

6 Fiberglass and Mold:As manufactured, fi berglass insulation is resistant to mold growth. However, mold growth can occur on building materials, including insulation, when it becomes contaminated with organic material and when water is present. To avoid mold growth on fi berglass insulation, remove any water that has accumulated and correct or repair the source of that water as soon as possible. Insulation that has become wet should be inspected for evidence of residual moisture and contamination, and any insulation that is contaminated should be promptly removed and Corning INSULATING SYSTEMS, LLCONE Owens Corning PARKWAYTOLEDO, OHIO 436591-800-GET-PINK No. 10011273-D. Printed in March 2015. THE PINK PANTHER & 1964-2015 Metro-Goldwyn-Mayer Studios Inc.

7 All Rights Reserved. The color PINK is a registered trademark of Owens Corning . 2015 Owens Corning . All Rights Gross Coverage Per Bag Attticat bagTo compensate for joists, the following table may be used to determine gross coverage per bag (sq. ft.)R-ValueJoist SizeCoverage/Bag (sq. ft.)16 in. 24 in x 42 x 62 x . x 42 x 62 x 8114 . 9118 .. 0115 . 2117. 4222 x 42 x 62 x x 42 x 62 x x 42 x 62 x x 42 x 62 x x 42 x 62 x x 42 x 62 x x 42 x 62 x of LiabilityTechnical information contained herein is furnished without charge or obligation and is given and accepted at recipient s sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with par ticular uses of any Product described herein.

8 Nothing contained in this bulletin shall be considered a Aislamiento expansible para soplarHoja de datos del productoEl aislamiento expansible para soplar AttiCat est dise ado para ser aplicado en ticos de casas nuevas y El aislamiento para soplar expansible AttiCat se fabrica cumpliendo con los requisitos de la norma ASTM C764 Tipo I (aplicaci n neum tica). Los valores R-se determinan seg n la norma ASTM C687. Cumple con los requisitos ASTM E136. Al ser probado, los c digos de edifi caci n modelo no lo consideran combustible. Las caracter sticas de combustibilidad superfi cial de este producto se han determinado seg n lo dispuesto en:ULC S E 84*Propagaci n del fuego00 Desarrollo de humo 00 El aislamiento para soplar expansible AttiCat :- No es corrosivo (cumple con ASTM C764, secci n )- No absorbe la humedad (cumple con ASTM C1104)- No permite el crecimiento del moho (cumple con ASTM C1338) Cumple con las normas de calidad del Estado de California.

9 Cumple con los requisitos del Programa de Normas de Aislamiento de o t rmicoEl valor R estipulado se logra si se instala la cantidad m nima de bolsas cada pies cuadrados netos, con un espesor que no sea inferior al espesor m nimo y el peso m nimo por pie2 que se indican en la etiqueta. Si el instalador no utiliza la cantidad necesaria de bolsas y no respeta al menos el espesor m nimo, el valor R del aislamiento ser desempe o t rmico del aislamiento var a debido a factores como la temperatura media, el asentamiento, la convecci n, la absorci n de humedad y las diferencias en la instalaci n. La convecci n del aislamiento suelto de fi bra de vidrio instalado en ticos abiertos puede provocar una reducci n de su desempe o t rmico en temperaturas invernales extremas durante la poca en que se utiliza la calefacci n.

10 El aislamiento suelto para soplar Atticat ha sido dise ado para anticipar este fen meno y el valor R que se indica en la etiqueta refl eja el desempe o promedio durante la poca invernal. El efecto sobre los gastos anuales de calefaccionamiento del propietario por la convecci n del aislamiento suelto es m nimo si se lo compara con el desempe o que se indica en la caciones para la instalaci n Owens Corning no recomienda ni aprueba la mezcla o el agregado de otros materiales o adhesivos a este producto durante su instalaci n. Owens Corning no aceptar ninguna responsabilidad ni obligaci n legal cuando el producto no sea instalado de acuerdo con las instrucciones de instalaci n y las indicaciones de las Corning recomienda y proporciona instrucciones para la instalaci n de aislamiento para soplar expansible AttiCat desde afuera de las paredes exteriores.