1 2021 CarrierForm 50 FCQ-4-7-02PD Rev. A50 FCQ*04, 05, 06, 07 Single - Packaged Heat Pump with Optional Electric Heatand Puron Refrigerant (R-410A) Product DataWeatherMaker Single Packaged Heat Pump Rooftop3 to 6 Nominal Tons2 The New Carrier WeatherMaker Packaged heat pump rooftop units (RTU) with EcoBlue Technology were designed by customers for customers and integrate new technology to provide value added benefits never seen in this type of equipment major design features include: Patent, industry s first efficientindoor fan system using Vane Axialfan with electric commutated vari-able speed motor Reliable fixed speed scroll compres-sor on 3-5 ton sizes and 2 stagescroll technology on 6 ton sizes Upgraded unit control board withintuitive indoor fan adjustment Reliable copper tube/aluminum fincondenser coil with 5/16-in.
2 Tubingto help reduce refrigerant chargeversus prior designs New outdoor fan system with rug-ged lightweight high impact com-posite fan blade50 FCQ WeatherMaker units up to 6tons are specifically designed to fit onCarrier roof curbs that were installedback to 1989, which makes replace-ment easy and eliminates the need forcurb adapters or changing units deliver SEERs up IEERs up to and heatingHSPFs up to All models arecapable of either vertical or Carrier rooftop unit (RTU) wasdesigned by customers for no-strip screw collars, handledaccess panels, and more, the unit iseasy to install, easy to maintain, andeasy to use. Precisely sized SuctionLine Accumulator to help insure reli-able operation at unit operation features include: Puron refrigerant (R-410A) Single point electrical connections optional fully integrated SystemVu controls RTU Open controller for BACnet1,LonWorks2, Modbus3 and JohnsonControls N2 3 to 5 ton models use fixed refriger-ant metering devices and 6 tonmodels use a TXV scroll compressors with internalline-break overload protection easy access tool-less filter door.
3 Fil-ter track tilts out for filter removaland replacement. All filters are thesame size in each unitInstallation easeAll WeatherMaker units are field-convertible to horizontal airflow, whichmakes it easy to adjust to unexpectedjob-site complications. Lighter unitsmake for easy replace. Simple, fastplug-in connections to the standardintegrated unit control board (UCB).Clearly labeled connections points toreduce installation time. Also, a largecontrol box provides room to work androom to mount Carrier to maintainWith the new EcoBlue Vane Axial fansystem and direct drive ECM motor,there is no longer a need to adjust beltsor pulleys as in past designs. This freesup maintenance and installation access handles by Carrier providequick and easy access to all normallyserviced components.
4 Our no-strip screw system has superior holdingpower and guides screws into positionwhile preventing the screw from strip-ping the unit s , corrosion resistant compositedrain pan sheds water; and won t to useThe newly re-designed Unit ControlBoard by Carrier puts all connectionsand troubleshooting points in one con-venient place. Most low voltage con-nections are made to the same boardand make it easy to access it. Settingup the fan is simple by an intuitiveswitch and rotary dial rooftops have high and lowpressure switches, a filter drier, and2-in. filters BACnet is a registered trademark of ASHRAE (American Society of Heating, Re-frigerating and Air-Conditioning Engineers).
5 2. LonWorks is a registered trademark of Echelon Modbus is a registered trademark of Schneider of contentsPageFeatures/Benefits .. 2 Model Number Nomenclature .. 4 Capacity Ratings .. 5 Physical Data .. 7 Options and Accessories .. 9 Base Unit Dimensions .. 13 Accessory Dimensions .. 16 Performance Data .. 17 Fan Data .. 29 Electrical Data .. 58 Typical Wiring Diagrams .. 81 Sequence of Operation .. 95 Application Data .. 97 Guide Specifications .. 983 EcoBlue TechnologyDirect drive EcoBlue Technologyindoor fan system uses Vane Axial fandesign and direct drive electrically com-mutated new Vane Axial design over pastbelt drive systems has 75% fewer mov-ing parts, uses up to 40% less energyand has no fan belts, blower bearingsand control and integrationCarrier controllers make connectingWeatherMaker rooftops into existingbuilding automation systems easy.
6 Theunits are compatible with conventionalthermostat controls, SystemVu con-trols and Carrier RTU Open multi-protocol efficiency and flexibilityThe 50 FCQ rooftops meet ASHRAE(American Society of Heating, Refriger-ating, and Air-Conditioning Engineers) , IECC1-2018 (InternationalEnergy Conservation Code) minimumefficiency convertible airflow All WeatherMaker 3 to 6 ton units arefield-convertible to horizontal airflow,which makes it easy to adjust to unex-pected controlCarrier s Round Tube Plate Fin coildesign helps maximize heat transferand reliable IECC is a registered trademark of the Inter-national Code Council, Efficiency Outdoor Fan Non-corrosive blade Balanced blade Efficient airflow collarVane Axial Indoor Fan Direct drive ECM Slow ramp up Phase loss protection No belts or pulleys Slide out assemblyEfficient Coils Round tube/plate fin Copper/Aluminum Special coating available New / -in.
7 Condenser tubeCompression Fully hermetic scroll Internally protected Single stage (3 to 5 tons) Two-stage (6 tons) Suction line accumlatorCabinet Design Heavy gage base rails Large handled access panels Tool-less filter access door Replacement original fit designHeating Electric Heating Field installed accessory Integral fusing Multiple kW sizes available Terminal block connections Single point powerUnit controls Base unit controller Switch/dial fan setting Large terminal connections Time/Temp defrost logic SystemVu option Large Display Quick LED status iVu , CCN, BACnet RTU Open option Multi-protocol controller450 FCQ MODEL NUMBER NOMENCLATURE Model Series - WeatherMaker FC SEER Standard Efficiency, sizes 04-06 IEER Standard Efficiency.
8 Size 07 Unit Heat Type50 Electric Heat Packaged RooftopCooling Tons04 = 3 tons05 = 4 tons06 = 5 tons07 = 6 tons Heat SizeQ = Heat Pump Sensor OptionsA = NoneB = Return Air (RA) Smoke DetectorC = Supply Air (SA) Smoke DetectorD = RA + SA Smoke DetectorE = CO2 SensorF = RA Smoke Detector and CO2 SensorG = SA Smoke Detector and CO2 SensorH = RA + SA Smoke Detector and CO2 SensorJ = Condensate Overflow Switch K = Condensate Overflow Switch and RA Smoke DetectorL = Condensate Overflow Switch and RA and SA Smoke DetectorsM = Condensate Overflow Switch and SA Smoke DetectorIndoor Fan Options1 = Direct Drive EcoBlue Standard Static2 = Direct Drive EcoBlue Medium Static3 = Direct Drive EcoBlue High StaticRefrig.
9 Systems OptionsA = Standard One Stage Cooling Models (sizes 04-06)M = Single Circuit, Two Stage Cooling (size 07 only)Coil Options (Outdoor - Indoor - Hail Guard)A = Al/Cu - Al/CuB = Precoat Al/Cu - Al/CuC = E-coat Al/Cu - Al/CuD = E-coat Al/Cu - E-coat Al/CuE = Cu/Cu - Al/CuF = Cu/Cu - Cu/CuM = Al/Cu - Al/Cu Louvered Hail GuardN = Precoat Al/Cu - Al/Cu Louvered Hail GuardP = E-coat Al/Cu - Al/Cu Louvered Hail GuardQ = E-coat Al/Cu - E-coat Al/Cu Louvered Hail GuardR = Cu/Cu - Al/Cu Louvered Hail GuardS = Cu/Cu - Cu/Cu Louvered Hail GuardDesign Revision- = Factory Design Revision Base Unit Controls0 = Electro-mechanical Controls can be used with field-installed W7212 EconoMi$er IV (Non-Fault Detection and Diagnostic)
10 2 = RTU Open Multi-Protocol Controller3 = SystemVuTM Controls6 = Electro-mechanical Controls can be used with W7220 EconoMi$er X (with Fault Detection and Diagnostic)Intake / Exhaust OptionsA = NoneB = Temperature Economizer w/ Barometric ReliefF = Enthalpy Economizer w/ Barometric Relief K = Two-Position Damper (sizes 04-06 only)U = Temperature Ultra Low Leak Economizer w/ Barometric ReliefW = Enthalpy Ultra Low Leak Economizer w/ Barometric ReliefService Options0 = None1 = Unpowered Convenience Outlet2 = Powered Convenience Outlet3 = Hinged Panels4 = Hinged Panels and Unpowered Convenience Outlet5 = Hinged Panels and Powered Convenience Outlet Packaging & Seismic Compliance0 = Standard1 = LTLE lectrical Options A = NoneC = Non-Fused DisconnectD = Thru-The-Base ConnectionsF = Non-Fused Disconnect and Thru-The-Base ConnectionsExample:Position.