Example: stock market

Product Data WeatherMaker Single Packaged Heat Pump …

2021 CarrierForm 50 FCQ-4-7-02PD Rev. A50 FCQ*04, 05, 06, 07 Single - Packaged Heat Pump with Optional Electric Heatand Puron Refrigerant (R-410A) Product DataWeatherMaker Single Packaged Heat Pump Rooftop3 to 6 Nominal Tons2 The New Carrier WeatherMaker Packaged heat pump rooftop units (RTU) with EcoBlue Technology were designed by customers for customers and integrate new technology to provide value added benefits never seen in this type of equipment major design features include: Patent, industry s first efficientindoor fan system using Vane Axialfan with electric commutated vari-able speed motor Reliable fixed speed scroll compres-sor on 3-5 ton sizes and 2 stagescroll technology on 6 ton sizes Upgraded unit control board withintuitive indoor fan adjustment Reliable copper tube/aluminum fincondenser coil with 5/16-in. tubingto help reduce refrigerant chargeversus prior designs New outdoor fan system with rug-ged lightweight high impact com-posite fan blade50 FCQ WeatherMaker units up to 6tons are specifically designed to fit onCarrier roof curbs that were installedback to 1989, which makes replace-ment easy and eliminates the need forcurb adapters or changing units deliver SEERs up IEERs up to and heatingHSPFs up to All models arecapable of either vertical or Ca

ating, and Air-Conditioning Engineers) 90.1-2016, IECC1-2018 (International Energy Conservation Code) minimum efficiency requirements. Field convertible airflow All WeatherMaker 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unex-pected job-site. Comfort control

Tags:

  Control, Conditioning

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Product Data WeatherMaker Single Packaged Heat Pump …

1 2021 CarrierForm 50 FCQ-4-7-02PD Rev. A50 FCQ*04, 05, 06, 07 Single - Packaged Heat Pump with Optional Electric Heatand Puron Refrigerant (R-410A) Product DataWeatherMaker Single Packaged Heat Pump Rooftop3 to 6 Nominal Tons2 The New Carrier WeatherMaker Packaged heat pump rooftop units (RTU) with EcoBlue Technology were designed by customers for customers and integrate new technology to provide value added benefits never seen in this type of equipment major design features include: Patent, industry s first efficientindoor fan system using Vane Axialfan with electric commutated vari-able speed motor Reliable fixed speed scroll compres-sor on 3-5 ton sizes and 2 stagescroll technology on 6 ton sizes Upgraded unit control board withintuitive indoor fan adjustment Reliable copper tube/aluminum fincondenser coil with 5/16-in. tubingto help reduce refrigerant chargeversus prior designs New outdoor fan system with rug-ged lightweight high impact com-posite fan blade50 FCQ WeatherMaker units up to 6tons are specifically designed to fit onCarrier roof curbs that were installedback to 1989, which makes replace-ment easy and eliminates the need forcurb adapters or changing units deliver SEERs up IEERs up to and heatingHSPFs up to All models arecapable of either vertical or Carrier rooftop unit (RTU) wasdesigned by customers for no-strip screw collars, handledaccess panels, and more, the unit iseasy to install, easy to maintain, andeasy to use.

2 Precisely sized SuctionLine Accumulator to help insure reli-able operation at unit operation features include: Puron refrigerant (R-410A) Single point electrical connections optional fully integrated SystemVu controls RTU Open controller for BACnet1,LonWorks2, Modbus3 and JohnsonControls N2 3 to 5 ton models use fixed refriger-ant metering devices and 6 tonmodels use a TXV scroll compressors with internalline-break overload protection easy access tool-less filter door. Fil-ter track tilts out for filter removaland replacement. All filters are thesame size in each unitInstallation easeAll WeatherMaker units are field-convertible to horizontal airflow, whichmakes it easy to adjust to unexpectedjob-site complications. Lighter unitsmake for easy replace. Simple, fastplug-in connections to the standardintegrated unit control board (UCB).Clearly labeled connections points toreduce installation time.

3 Also, a largecontrol box provides room to work androom to mount Carrier to maintainWith the new EcoBlue Vane Axial fansystem and direct drive ECM motor,there is no longer a need to adjust beltsor pulleys as in past designs. This freesup maintenance and installation access handles by Carrier providequick and easy access to all normallyserviced components. Our no-strip screw system has superior holdingpower and guides screws into positionwhile preventing the screw from strip-ping the unit s , corrosion resistant compositedrain pan sheds water; and won t to useThe newly re-designed Unit ControlBoard by Carrier puts all connectionsand troubleshooting points in one con-venient place. Most low voltage con-nections are made to the same boardand make it easy to access it. Settingup the fan is simple by an intuitiveswitch and rotary dial rooftops have high and lowpressure switches, a filter drier, and2-in.

4 Filters BACnet is a registered trademark of ASHRAE (American Society of Heating, Re-frigerating and Air- conditioning Engineers).2. LonWorks is a registered trademark of Echelon Modbus is a registered trademark of Schneider of contentsPageFeatures/Benefits .. 2 Model Number Nomenclature .. 4 Capacity Ratings .. 5 Physical Data .. 7 Options and Accessories .. 9 Base Unit Dimensions .. 13 Accessory Dimensions .. 16 Performance Data .. 17 Fan Data .. 29 Electrical Data .. 58 Typical Wiring Diagrams .. 81 Sequence of Operation .. 95 Application Data .. 97 Guide Specifications .. 983 EcoBlue TechnologyDirect drive EcoBlue Technologyindoor fan system uses Vane Axial fandesign and direct drive electrically com-mutated new Vane Axial design over pastbelt drive systems has 75% fewer mov-ing parts, uses up to 40% less energyand has no fan belts, blower bearingsand control and integrationCarrier controllers make connectingWeatherMaker rooftops into existingbuilding automation systems easy.

5 Theunits are compatible with conventionalthermostat controls, SystemVu con-trols and Carrier RTU Open multi-protocol efficiency and flexibilityThe 50 FCQ rooftops meet ASHRAE(American Society of Heating, Refriger-ating, and Air- conditioning Engineers) , IECC1-2018 (InternationalEnergy Conservation Code) minimumefficiency convertible airflow All WeatherMaker 3 to 6 ton units arefield-convertible to horizontal airflow,which makes it easy to adjust to unex-pected controlCarrier s Round Tube Plate Fin coildesign helps maximize heat transferand reliable IECC is a registered trademark of the Inter-national Code Council, Efficiency Outdoor Fan Non-corrosive blade Balanced blade Efficient airflow collarVane Axial Indoor Fan Direct drive ECM Slow ramp up Phase loss protection No belts or pulleys Slide out assemblyEfficient Coils Round tube/plate fin Copper/Aluminum Special coating available New / -in.

6 Condenser tubeCompression Fully hermetic scroll Internally protected Single stage (3 to 5 tons) Two-stage (6 tons) Suction line accumlatorCabinet Design Heavy gage base rails Large handled access panels Tool-less filter access door Replacement original fit designHeating Electric Heating Field installed accessory Integral fusing Multiple kW sizes available Terminal block connections Single point powerUnit controls Base unit controller Switch/dial fan setting Large terminal connections Time/Temp defrost logic SystemVu option Large Display Quick LED status iVu , CCN, BACnet RTU Open option Multi-protocol controller450 FCQ MODEL NUMBER NOMENCLATURE Model Series - WeatherMaker FC SEER Standard Efficiency, sizes 04-06 IEER Standard Efficiency, size 07 Unit Heat Type50 Electric Heat Packaged RooftopCooling Tons04 = 3 tons05 = 4 tons06 = 5 tons07 = 6 tons Heat SizeQ = Heat Pump Sensor OptionsA = NoneB = Return Air (RA) Smoke DetectorC = Supply Air (SA)

7 Smoke DetectorD = RA + SA Smoke DetectorE = CO2 SensorF = RA Smoke Detector and CO2 SensorG = SA Smoke Detector and CO2 SensorH = RA + SA Smoke Detector and CO2 SensorJ = Condensate Overflow Switch K = Condensate Overflow Switch and RA Smoke DetectorL = Condensate Overflow Switch and RA and SA Smoke DetectorsM = Condensate Overflow Switch and SA Smoke DetectorIndoor Fan Options1 = Direct Drive EcoBlue Standard Static2 = Direct Drive EcoBlue Medium Static3 = Direct Drive EcoBlue High StaticRefrig. Systems OptionsA = Standard One Stage Cooling Models (sizes 04-06)M = Single Circuit, Two Stage Cooling (size 07 only)Coil Options (Outdoor - Indoor - Hail Guard)A = Al/Cu - Al/CuB = Precoat Al/Cu - Al/CuC = E-coat Al/Cu - Al/CuD = E-coat Al/Cu - E-coat Al/CuE = Cu/Cu - Al/CuF = Cu/Cu - Cu/CuM = Al/Cu - Al/Cu Louvered Hail GuardN = Precoat Al/Cu - Al/Cu Louvered Hail GuardP = E-coat Al/Cu - Al/Cu Louvered Hail GuardQ = E-coat Al/Cu - E-coat Al/Cu Louvered Hail GuardR = Cu/Cu - Al/Cu Louvered Hail GuardS = Cu/Cu - Cu/Cu Louvered Hail GuardDesign Revision- = Factory Design Revision Base Unit Controls0 = Electro-mechanical Controls can be used with field-installed W7212 EconoMi$er IV (Non-Fault Detection and Diagnostic)

8 2 = RTU Open Multi-Protocol Controller3 = SystemVuTM Controls6 = Electro-mechanical Controls can be used with W7220 EconoMi$er X (with Fault Detection and Diagnostic)Intake / Exhaust OptionsA = NoneB = Temperature Economizer w/ Barometric ReliefF = Enthalpy Economizer w/ Barometric Relief K = Two-Position Damper (sizes 04-06 only)U = Temperature Ultra Low Leak Economizer w/ Barometric ReliefW = Enthalpy Ultra Low Leak Economizer w/ Barometric ReliefService Options0 = None1 = Unpowered Convenience Outlet2 = Powered Convenience Outlet3 = Hinged Panels4 = Hinged Panels and Unpowered Convenience Outlet5 = Hinged Panels and Powered Convenience Outlet Packaging & Seismic Compliance0 = Standard1 = LTLE lectrical Options A = NoneC = Non-Fused DisconnectD = Thru-The-Base ConnectionsF = Non-Fused Disconnect and Thru-The-Base ConnectionsExample:Position:50 FCQA04A2A5 -0A0A01234567891011 12 13 14 15 16 17 18 Voltage1 = 575/3/603 = 208-230/1/605 = 208-230/3/606 = 460/3/60 Note: On Single phase (-3 voltage code) models, the following are not available as a factory-installed option.

9 - Two-Position Damper - Coated Coils or Cu Fin Coils - Louvered Hail Guards - Economizer or 2-Position Damper - Powered 115 Volt Convenience Outlet Model number nomenclature5 LEGENDNOTES:1. Rated and certified under AHRI Standard 210/240 (04-06 size)and 340/360 (07 size).2. Ratings are based on:Cooling Standard: 80 F (27 C) db, 67 F (19 C) wb indoor airtemperature and 95 F (35 C) db outdoor air Temperature Heating Ratings: 47 F (8 C) db, 43 F (6 C) wboutdoor air temperature and 70 F (21 C) entering indoor coil Temperature Heating Ratings: 17 F ( 8 C) db, 15 F ( 9 C) wboutdoor air temperature and 70 F (21 C) entering indoor coil All 50 FCQ units comply with ASHRAE Energy Standard forminimum SEER and EER RATINGSCOOLING MODE50 FCQCOOLING STAGESNOM. CAPACITY(tons)NET COOLING CAPACITY(Btuh)TOTAL POWER(kW)SEEREERIEER w/2-SPEEDA041336, , , , MODE50 FCQHSPFHIGH HEATING CAPACITY (Btuh)HIGH HEATCOPLOW HEATING CAPACITY (Btuh)LOW , , , , , , , , Air conditioning , Heating and Refrigeration InstituteASHRAE American Society of Heating, Refrigerating and Air Con-ditioning EngineersCOP Coefficient of PerformanceEER Energy Efficiency RatioHSPF Heating Seasonal Performance FactorIEER Integrated Energy Efficiency RatioSEER Seasonal Energy Efficiency RatioCapacity ratings6 SOUND RATINGS TABLELEGENDNOTES:1.

10 Outdoor sound data is measured in accordance with Measurements are expressed in terms of sound power. Do notcompare these values to sound pressure values because soundpressure depends on specific environmental factors which nor-mally do not match individual applications. Sound power valuesare independent of the environment and therefore more A-weighted sound ratings filter out very high and very low frequen-cies, to better approximate the response of average human measurements for Carrier units are taken in accor-dance with - MAXIMUM AIRFLOW RATINGS (CFM) COOLING UNITS AND ACCESSORY ELECTRIC HEAT* Electric heat modules are available as field-installed accessories for 50 FCQ UNITCOOLING STAGESOUTDOOR SOUND (dB) AT 60 DecibelUNITCOOLINGELECTRIC HEAT*MINIMUM AIRFLOW CFMMINIMUM 2-SPEED AIRFLOW (LOW SPEED)MINIMUM 2-SPEED AIRFLOW (HIGH SPEED)MAXIMUM AIRFLOW CFMMINIMUM AIRFLOW CFMMAXIMUM AIRFLOW CFM50 FCQA04900N/AN/A1500 900150050 FCQA051200N/AN/A20001200200050 FCQA061500N/AN/A25001500250050 FCQM07180012001800300018003000 Capacity ratings (cont)