Transcription of PRODUCT GUIDE - Elektrooprema
1 Network MonitorNemo D44 module housingNemo D66 module housingNemo D88 module housingNemo 7272x72 mm flush mounting housing Nemo 9696x96 mm flush mounting housingNemo LD144x72 mm flush mounting housingNemo IFmultifunction interfaceVia Travaglia 7 20094 CORSICO (MI) ITALY Tel. +39 02 44 Fax +39 02 45 86 76 63 T GUIDEISTRUMENTI MISURE ELETTRICHE SpAI6wiring connections page 18-19-20 overall dimensions page 29 Network Monitor5A10A15A20A25A30A40A50A60A70A75A8 0A100A120A125A150A160A200A250A300A400A50 0A600A700A750A800A1000A1200A1250A1500A16 00A2000A2500A3000A3200A4000A5000A6000A70 00A7500A8000 APrimary currents selectable by front keyboardTable AModelNemo D4-bNemo D4-LNemo codes see page.
2 171617161414single phase,Connection on line3-phase 3/4 wiressingle phase, 3-phase 3/4 wires unbalanced load3-phase 3/4 wires unbalanced loadunbalanced loadIsolated input Non-isolated input LCD Display Voltage, current, frequency Neutral current Average currents and max. values Active, reactive, apparent power Phase active and reactive power Average power and max. value Power factor Active energy cl. 1 Active energy cl. 2 Reactive energy cl. 3 Hourmeter Phase sequence 3 alarm relays Pulse energy RS485 communication M Analogue outputMMProfibusMMM1A or 5A from CTInput currentselectable1A or 5A from CT programmable ratio1A or 5A direct or from CT primary currentprogrammable ratio(table A)Input direct or from VT (phase-phase) direct or from VT(phase-phase)programmable ratio(phase-phase)
3 Programmable auxiliary supply115 Vor or or 230V or 240 Vor auxiliary or module DIN4 module DIN8 module DINT echnical noteNT588NT604NT525NT360 PriceExtra price auxiliary supplyExtra price 1A input currentLegend: Mexternal interface (see NEMO IF page 12)7 Network Monitorwiring connections page 21-22-23 overall dimensions page 295A20A25A30A40A50A60A70A75A80A100A120A1 25A150A200A250A300A400A500A600A700A750A8 00A1000A1200A1250A1500A1600A2000A2500A30 00A3200A4000A5000A6000A7000A7500A8000 APrimary currents selectable by front keyboardTable BModelNemo D6-lNemo codes see page.
4 131313141414 Connection on line3-phase 3/4 wire unbalanced load3-phase 3/4 wire unbalanced loadIsolated input Non-isolated input LEDD isplay Voltage, current, frequency Active, reactive, apparent power Average power and max. value Power factor Active energy cl. 2 Reactive energy cl. 3 Pulse energy RS485 communication RS232 communication ProfibusMMInput current5A from CT selectable primary current5A from CT selectable primary current(table B)(table B)Input direct (phase-phase) direct (phase-phase) auxiliary supply115V or 230V or 240V115V or 230V or 240 VDimensions6 module DIN6 module DINT echnical noteNT635NT528 PriceLegend: M external interface (see NEMO IF page 12)8wiring connections page 24 overall dimensions page 29 Network MonitorModelNemo 72-bNemo codes see page.
5 17171717 Connection on linesingle-phase / 3-phase 3-phase 3/4 wires,single-phase, 3-phase 3/4 wires, unbalanced load4wires, unbalanced loadunbalanced loadNon-isolated input LCD Display Voltage, current, frequency Neutral current Average currents and max. values Active, reactive, apparent power Phase active and reactive power Average power and max. value Power factor Active energy cl. 2 Reactive energy cl. 3 Total current armonic distortionHourmeter Phase sequence Active energy pulses RS485 communication ProfibusMInput current1A or 5A from CT selectable primary current1A or 5A from CT programmable ratio(table A)Input direct (phase-phase) direct or from VT (phase-phase)programmable auxiliary supplyselfsupplied115V or auxiliary noteNT651NT652 PriceExtra price auxiliary supplyExtra price 1A input currentLegend.
6 Mexternal interface (see NEMO IF page 12)5A10A15A20A25A30A40A50A60A70A75A80A10 0A120A125A150A160A200A250A300A400A500A60 0A700A750A800A1000A1200A1250A1500A1600A2 000A2500A3000A3200A4000A5000A6000A7000A7 500A8000 APrimary currents selectable by front keyboardTable A9 Network Monitorwiring connections page 21-22-23 overall dimensions page 305A20A25A30A40A50A60A70A75A80A100A120A1 25A150A200A250A300A400A500A600A700A750A8 00A1000A1200A1250A1500A1600A2000A2500A30 00A3200A4000A5000A6000A7000A7500A8000 APrimary currents selectable by front keyboardTable BModelNemo
7 96-INemo codes see page:14141414 Connection on linethree-phase 3/4 wire unbalanced loadthree-phase 3/4 wire unbalanced loadIsolated input Non-isolated input LED Display Voltage, current, frequency Active, reactive, apparent power Average power and max. value Power factor Active energy cl. 2 Reactive energy cl. 3 Active energy pulses RS485 communication ProfibusMMInput current5A from CT selectable primary current5A from CT selectable primary current(table B)(table B)Input direct (phase-phase) direct (phase-phase) auxiliary supply115V or 230V or 240V115V or 230V or 240 VDimensions96x96x64,5mm96x96x64,5mmTechn ical noteNT636NT553 PriceLegend: Mexternal interface (see NEMO IF page 12)10wiring connections page 25-26-27 overall dimensions page 30 Network MonitorModelNemo codes see page.
8 151515151616 Connection on linethree-phase 3/4 wire unbalanced loadIsolated input LCD Display Voltage, current, frequency Neutral current Active, reactive, apparent power Phase active power Average power and max. value Power factor Active energy cl. 1 Reactive energy cl. 3 Total current armonic distortionTotal voltage armonic distortionActive energy pulses Reactive energy pulses RS485 communication Analogue output ProfibusM LonWorks Input current1A or 5A direct or from CT programmable ratioInput direct or from VT (phase-phase) programmable auxiliary supply115V or 230V or or auxiliary or noteNT490NT593NT585NT646 PriceExtra price auxiliary supplyExtra price 1A input currentLegend.
9 Mexternal interface (see NEMO IF page 12)11 Network Monitorwiring connections page 28 overall dimensions page 30 ModelNemo codes see page:1616 Connection on linethree-phase 3/4 wire unbalanced loadIsolated input LCD Display Voltage, current, frequency Active, reactive, apparent power Average power and max. value Power factor Active energy Reactive energy cl. 3 Imported and exported energy Active energy pulses RS485 communication Analogue outputMMProfibusMMInput current1A or 5A direct or from CT programmable ratioInput direct or from VT (phase-phase) programmable auxiliary supply115V or 230V or auxiliary or noteNT456NT458 PriceExtra price auxiliary supplyExtra price 1A input current Legend:Mexternal interface (see NEMO IF page 12)12 ModelNemo codes see page.
10 131313 Interface typedigital / 1 analogue outputsdigital / 4 analogue outputsRS485 communicationInputconnection to DI2 output ofconnection to DI2 output ofconnection to DI1 output NEMO D8 or NEMO LDNEMO D8 or NEMO LDof NEMO D80-20mA or 4-20mA0-20mA or 4-20mAOutputor 0-10V(possibility to be used withRS485 protocol JBUS/MODBUS configuration with common negative) auxiliary supply 115V or 230V or 240V115V or 230V or 240V115V or 230V or auxiliary or or module DIN8 module DIN4 module DINT echnical noteNT361NT485NT362 PriceExtra price auxiliary supplyInterfacewiring connections page 28 overall dimensions page 29ON REQUESTCodeDescriptionSWMFIM anagement software for Network Monitor with RS485 outputModelNemo codes see page.