Example: bachelor of science

Product Specification and Schedule Sheet AX

FOCUSAXE330 FOCUSAX E350 FOCUS AX-SD Single Phase E330 FOCUSAXP olyphaseThe FOCUS family of meters featuring advanced residential metering and lightcommercial FOCUS AX platform features a single circuit board design,mounted at the front of the meter, allows room for modularadvanced metering communications or a KYZ option outputboard. Fewer parts and connectors throughout the board designincrease reliability and contribute to better overall end pointperformance. Highly accurate load performance and the use of a field-proven Digital Multiplication Measurement Techniqueensure reliability and dependability during the entire life of theFOCUS AX Next Generation of Advanced Residential MeteringThe FOCUS AX-SD is an advanced meter platform with featuresthat rival any meter in its class.

•Uses ANSI protocol (between meter and communication device) ... Metrum CDMA/1xRTT and GSM/GPRS under glass Sensus Flex Net Silver Spring 2 Way RF Mesh Trilliant 2 Way SecureMesh Specifications. Form Nominal Voltage Current Class Test Amps Starting Load Kh 1S 120V CL 100 15.0 0.030 Amp (3.6W) 1.8

Tags:

  Communication, Protocol, Gprs

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of Product Specification and Schedule Sheet AX

1 FOCUSAXE330 FOCUSAX E350 FOCUS AX-SD Single Phase E330 FOCUSAXP olyphaseThe FOCUS family of meters featuring advanced residential metering and lightcommercial FOCUS AX platform features a single circuit board design,mounted at the front of the meter, allows room for modularadvanced metering communications or a KYZ option outputboard. Fewer parts and connectors throughout the board designincrease reliability and contribute to better overall end pointperformance. Highly accurate load performance and the use of a field-proven Digital Multiplication Measurement Techniqueensure reliability and dependability during the entire life of theFOCUS AX Next Generation of Advanced Residential MeteringThe FOCUS AX-SD is an advanced meter platform with featuresthat rival any meter in its class.

2 With available service disconnectintegrated into the meter base, utilities can take advantage of the200 Amp relay to disconnect power or limit service remotely usingan advanced metering technology or manually at the meter. Thecombinations of FOCUS Service Disconnect base module andpowerful AX register provides a flexible system that supports avariety of connect/disconnect and service-limiting applications. Economical and Reliable Option for Light Commercial ApplicationsThe FOCUSAX Polyphase meter provides a cost-efficientalternative for light commercial metering applications that do notrequire all of the functionally of the S4e meter.

3 The FOCUS AXPolyphase meter contains a 120V to 277V auto-ranging powersupply suitable for both 277/480V, 4W, WYE and 240/480V 4-wireDelta Services. As an addition to the FOCUS family of meters, the AX Polyphase brings the same proven solid-state performanceutilities have come to expect from FOCUS meters, in aneconomical and AMI-ready platform for commercial and industrial Specification and Schedule SheetKey Benefits Digital Multiplication MeasurementTechnique Non-volatile memory Designed for a 20+ year life Meets or exceeds industry and ANSI standards Uses ANSI protocol (between meterand communication device) 6 digit LCD and 3 Alpha ID Selectable meter multiplier up to 240 (1200.)

4 5 CT) Product Specification and Schedule SheetGeneral SpecificationsActive Energy kWh-kW meterDigital Multiplication Measurement TechniqueNon-Volatile MemoryDesigned for 20+ years lifeMeets ANSI standards for performanceUtilizes ANSI protocol (between meter and AMI device)9 digit LCDD isplay scroll sequence programmable (factory or end user)Configuration port cover does not have to be removed or optional ANSI optical port available Operating Temperature-40C to +85C under coverOperating Voltage80% to 115% of VnFrequency60Hz +/- 5%Humidity5% to 95% relative humidity, non condensingVoltage Burden MaxLoad Performance AccuracyAccuracy Class typical accuracy : Form 36S OptionsEnergy Metrics.

5 +kWh, -kWh, Net kWh, and added kWh (Security) Metric Energy Display Format 4x1, 4x10, 5x1, 5x10, 6x1 or 6x10 Time of Use and Demand BillingAMI PlatformModular or IntegratedSelectable Meter MultiplierUp to 4096 as result of PT ratio CT ratioApplicable StandardsANSI for electric metersANSI for physical aspects of watt hour metersANSI protocol specifications for ANSI Type 2 Optical PortANSI Utility Industry End Device Data TablesANSI for electricity meters, and accuracy classesCAN3-C17-M84 Canadian specifications for approval of type of electricity metersService Disconnect10.

6 000 operations at full rated current (disconnect/connect)Landis+Gyr CommunicationFOCUS AX Single Phase2 Way Gridstream RF2 Way Gridstream PLCFOCUS AX-SD2 Way Gridstream RF2 Way Gridstream PLCFOCUS AX Polyphase2 Way Gridstream RFThird Party CommunicationFOCUS AX Single PhaseAclara STAR Network - RFAclara TWACS Technology - PLCS ensus 2 Way RF Flex NetSilver Spring 2 Way RF MeshTrilliant 2 Way SecureMeshFOCUS AX-SDAclara STAR Network RFAclara TWACS Technology PLCS ensus Flex NetSilver Spring Network 2 Way RF MeshTrilliant 2 Way SecureMeshFOCUS AX PolyphaseAclara STAR Network RFAclara TWACS Technology

7 PLCM etrum CDMA/1xRTT and GSM/ gprs under glassSensus Flex NetSilver Spring 2 Way RF MeshTrilliant 2 Way SecureMeshSpecificationsForm Nominal Voltage Current ClassTest AmpsStarting LoadKh1S120 VCL Amp ( ) Amp (12W) / Amp (12W) / Amp ( ) / Amp ( ) 10 or Amp ( ) 10 or Amp ( ) 10 or Amp ( ) FOCUS AX Single-phase meter is available in the following forms:Form Nominal Voltage Current ClassTest AmpsStarting LoadKh1S120 VCL Amp ( ) Amp (12W) Amp (12W) / Amp (12W) FOCUS AX Service Disconnect meter is available in the following forms:Form Nominal Voltage Current ClassTest AmpsStarting LoadKh9S/8S120V 277 VCL Amp ( ) 277 VCL Amp (12W) 277 VCL Amp ( ) 277 VCL Amp (12W) 277 VCL Amp ( ) 277 VCL Amp (12W) 277 VCL Amp ( ) (6S)120V 277 VCL Amp ( ) (5S)120V 277 VCL Amp ( ) FOCUS AX Polyphase meter is available in the following forms.

8 Product Specification and Schedule SheetFOCUS AXNet Single PackSingle PackFour PackFour PackPalletPalletForm Lbs. 3/4" x 8 3/4" x 9" 1/2" x 7" x 15 1/2" 350 lbs. 31" x 46" x 37"2S(E) 3/4" x 8 3/4" x 9" 1/2" x 7" x 15 1/2" 350 lbs. 31" x 46" x 37" lbs. 12 9/16" x 12 9/16" x 9"N/A15 1/2" x 7" x 15 1/2" 195 lbs.* 31" x 46" x 37" 3/4" x 8 3/4" x 9" 1/2" x 7" x 15 1/2" 350 lbs. 31" x 46" x 37" 3/4" x 8 3/4" x 9" 1/2" x 7" x 15 1/2" 350 lbs. 31" x 46" x 37"5S/45S 3/4" x 8 3/4" x 9" 1/2" x 7" x 15 1/2" 350 lbs.

9 31" x 46" x 37"6S/36S 3/4" x 8 3/4" x 9" 1/2" x 7" x 15 1/2" 350 lbs. 31" x 46" x 37"8 3/4" x 8 3/4" x 9" 1/2" x 7" x 15 1/2" 350 lbs. 31" x 46" x 37"12S(E) 3/4" x 8 3/4" x 9" 1/2" x 7" x 15 1/2" 350 lbs. 31" x 46" x 37"16S(E) 3/4" x 8 3/4" x 9" 1/2" x 7" x 15 1/2" 350 lbs. 31" x 46" x 37"25S(E) 3/4" x 8 3/4" x 9" 1/2" x 7" x 15 1/2" 350 lbs.* 31" x 46" x 37"Standard pallet size of 96 meters* Denotes alternate pallet size of 30 metersNet Single PackSingle PackFour PackFour PackPalletPalletForm Lbs.

10 3/4" x 8 3/4" x 9" lbs. 15 1/2" x 7" x 15 1/2" 370 lbs. 31" x 46" x 37" 3/4" x 8 3/4" x 9" lbs. 15 1/2" x 7" x 15 1/2" 370 lbs. 31" x 46" x 37" 3/4" x 8 3/4" x 9" lbs. 15 1/2" x 7" x 15 1/2" 370 lbs. 31" x 46" x 37" 3/4" x 8 3/4" x 9" lbs. 15 1/2" x 7" x 15 1/2" 370 lbs. 31" x 46" x 37"FOCUS AX-SD:FOCUS Single Phase/Polyphase: Product Specification and Schedule SheetFOCUS AXFOCUS AX S-BaseFOCUS AX K-BaseOptical Port/Reset/Reconnect Switch???????Configuration Port OnlyConfiguration Port/Reconnect OnlyCover OptionsOptical Port/Reconnect Only Optical Port OnlyOptical Port/Reset (No Options) Product Specification and Schedule Sheet 2010 Landis+Gyr 12/21/10 FOCUS AX2800 Duncan RoadLafayette, IN 47904 : Support: : Specification and Schedule SheetWith focus on customer satisfaction, we are committed toproviding the best metering solution in terms of capability,technology and affordability.