Example: stock market

Proline Promag P 300 - Endress+Hauser

The flowmeter for highest medium temperatures with a compact, easilyaccessible transmitterApplication The measuring principle is virtually independent of pressure,density, temperature and viscosity Dedicated for chemical and process applications withcorrosive liquids and high medium temperaturesDevice properties Nominal diameter: max. DN 600 (24") All common Ex approvals Liner made of PTFE or PFA Compact dual compartment housing with up to 3 I/Os Backlit display with touch control and WLAN access Remote display availableYour benefits Versatile applications wide variety of wetted materials Energy-saving flow measurement no pressure loss due tocross-section constriction Maintenance-free no moving parts Full access to process and diagnostic information numerous, freely combinable I/Os and fieldbuses Reduced complexity and variety freely configurable I/Ofunctionality Integrated verification Heartbeat TechnologyProductsSolutionsServicesTechn ical InformationProline Promag P 300 Electromagnetic flowmeterTI01224D/06/ Pro

Proline Promag P 300 6 Endress+Hauser Measuring system The device consists of a transmitter and a sensor. The device is available as a compact version: The transmitter and sensor form a mechanical unit. Transmitter Promag 300 A0026708 Device versions and materials: • Transmitter housing Aluminum, coated: aluminum, AlSi10Mg, coated

Tags:

  Promag, Proline, Proline promag

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Proline Promag P 300 - Endress+Hauser

1 The flowmeter for highest medium temperatures with a compact, easilyaccessible transmitterApplication The measuring principle is virtually independent of pressure,density, temperature and viscosity Dedicated for chemical and process applications withcorrosive liquids and high medium temperaturesDevice properties Nominal diameter: max. DN 600 (24") All common Ex approvals Liner made of PTFE or PFA Compact dual compartment housing with up to 3 I/Os Backlit display with touch control and WLAN access Remote display availableYour benefits Versatile applications wide variety of wetted materials Energy-saving flow measurement no pressure loss due tocross-section constriction Maintenance-free no moving parts Full access to process and diagnostic information numerous.

2 Freely combinable I/Os and fieldbuses Reduced complexity and variety freely configurable I/Ofunctionality Integrated verification Heartbeat TechnologyProductsSolutionsServicesTechn ical InformationProline Promag P 300 Electromagnetic flowmeterTI01224D/06/ Promag P 3002 Endress+HauserTable of contentsDocument and system ..8 Measured flow and input on connection flow cut plugs assignment, device supply operating measured of ambient and outlet mounting temperature of compatibility (EMC).. temperature loss ..47 System in SI in US tube operating data and Fieldbus RS485 standards and Promag P 300 Endress+Hauser3 System device-dependent Promag P 3004 Endress+HauserDocument informationSymbols usedElectrical symbolsSymbolMeaningDirect currentAlternating currentDirect current and alternating currentGround connectionA grounded terminal which, as far as the operator is concerned, is grounded via agrounding ground connectionA terminal which must be connected to ground prior to establishing any connectionA connection that has to be connected to the plant grounding system.

3 This may be apotential equalization line or a star grounding system depending on national orcompany codes of symbolsSymbolMeaningWireless Local Area Network (WLAN)Communication via a wireless, local data transmission between devices over a short emitting diode is emitting diode is emitting diode is for certain types of informationSymbolMeaningPermittedProcedu res, processes or actions that are , processes or actions that are , processes or actions that are additional to documentationAReference to pageReference to graphicVisual inspectionProline Promag P 300 Endress+Hauser5 Symbols in graphicsSymbolMeaning1, 2, 3,..Item numbers1., 2., of stepsA, B, C, ..ViewsA-A, B-B, C-C, ..Sections-Hazardous area (non-hazardous area)Flow directionFunction and system designMeasuring principleFollowing Faraday's law of magnetic induction, a voltage is induced in a conductor moving through amagnetic A0028962 UeInduced voltageBMagnetic induction (magnetic field)LElectrode spacingICurrentvFlow velocityIn the electromagnetic measuring principle, the flowing medium is the moving conductor.

4 Thevoltage induced (Ue) is proportional to the flow velocity (v) and is supplied to the amplifier by meansof two measuring electrodes. The flow volume (Q) is calculated via the pipe cross-section (A). The DCmagnetic field is created through a switched direct current of alternating for calculation Induced voltage Ue = B L v Volume flow Q = A vProline Promag P 3006 Endress+HauserMeasuring systemThe device consists of a transmitter and a device is available as a compact version:The transmitter and sensor form a mechanical 300 A0026708 Device versions and materials: Transmitter housingAluminum, coated: aluminum, AlSi10Mg, coated Material of window in transmitter housing:Aluminum, coated: glassConfiguration: External operation via 4-line, backlit, graphic local display with touchcontrol and guided menus ("Make-it-run" wizards) for application-specific commissioning.

5 Via service interface or WLAN interface: Operating tools ( FieldCare, DeviceCare) Web server (access via Web browser, Microsoft InternetExplorer, Microsoft Edge)SensorPromag PNominal diameter range: DN 15 to 600 ( to 24")Materials: Sensor housing: Aluminum, AlSi10Mg, coated DN 15 to 300 ( to 12"): aluminum, AlSi10Mg, coated DN 350 to 600 (14 to 24"): carbon steel with protective varnish Measuring tubes 1): stainless steel, Liner: PFA, PTFE Electrodes: stainless steel, (F316L); Alloy C22, (UNSN06022); platinum; tantalum; titanium Process connections: stainless steel, 2) 2);carbon steel, A105/FE410WB 2)/HII/S235 JRG2/S275JR; Alloy C22, (UNS N06022) Seals: as per DIN EN 1514-1 Ground disks: stainless steel, (316L); Alloy C22, (UNSN06022); tantalum; titanium A00177031) For flanges made of carbon steel with Al/Zn protective coating (DN 15 to 300 ( to 12")) or protectivevarnish (DN 350 to 600 (14 to 24"))2) With Al/Zn protective coating (DN 15 to 300 ( to 12")) or protective varnish (DN 350 to 600 (14 to 24")) Proline Promag P 300 Endress+Hauser7 Equipment architecture21657433 A0027512 1 Possibilities for integrating measuring devices into a system1 Control system ( PLC)2 Connecting cable (0/4 to 20 mA HART etc.

6 3 Fieldbus4 Segment coupler5 Non-hazardous area6 Non-hazardous area and Zone 2/Div. 27 Hazardous area and Zone 1/Div. 1 SafetyIT securityWe only provide a warranty if the device is installed and used as described in the OperatingInstructions. The device is equipped with security mechanisms to protect it against any inadvertentchanges to the device security measures in line with operators' security standards and designed to provide additionalprotection for the device and device data transfer must be implemented by the operators IT securityThe device offers a range of specific functions to support protective measures on the operator's functions can be configured by the user and guarantee greater in-operation safety if usedcorrectly.

7 An overview of the most important functions is provided in the following access via hardware write protectionWrite access to the device parameters via the local display, Web browser or operating tool ( , DeviceCare) can be disabled via a write protection switch (DIP switch on themotherboard). When hardware write protection is enabled, only read access to the parameters write protection is disabled when the device is access via a passwordDifferent passwords are available to protect write access to the device parameters or access to thedevice via the WLAN interface. User-specific access codeProtect write access to the device parameters via the local display, Web browser or operating tool( FieldCare, DeviceCare).

8 Is equivalent to hardware write protection in terms of functionality. WLAN passphraseThe network key protects a connection between an operating unit ( notebook or tablet) and thedevice via the WLAN interface which can be ordered as an access codeWrite access to the device parameters via the local display, Web browser or operating tool ( , DeviceCare) can be protected by the modifiable, user-specific access Promag P 3008 Endress+HauserWhen the device is delivered, the device does not have an access code and is equivalent to 0000(open).WLAN passphraseA connection between an operating unit ( notebook or tablet) and the device via the WLAN interface which can be ordered as an option is protected by the network key.

9 The WLAN authentication of the network key complies with the IEEE the device is delivered, the network key is pre-defined depending on the device. It can bechanged via the WLAN settings submenu in the WLAN passphrase notes on the use of passwords The access code and network key supplied with the device should be changed duringcommissioning. Follow the general rules for generating a secure password when defining and managing the accesscode or network key. The user is responsible for the management and careful handling of the access code and via fieldbusWhen communicating via fieldbus, access to the device parameters can be restricted to "Read only"access. The option can be changed in the Fieldbus writing access does not affect cyclic measured value transmission to the higher-order system, which is information: "Description of Device Parameters" document pertaining to the device via Web serverThe device can be operated and configured via a Web browser with the integrated Web server.

10 Theconnection is via the service interface (CDI-RJ45) or the WLAN Web server is enabled when the device is delivered. The Web server can be disabled if necessary( after commissioning) via the Web server functionality device and status information can be hidden on the login page. This prevents unauthorizedaccess to the information: "Description of Device Parameters" document pertaining to the device variableDirect measured variables Volume flow (proportional to induced voltage) Electrical conductivityCalculated measured variables Mass flow Corrected volume flowMeasuring rangeTypically v = to 10 m/s ( to 33 ft/s) with the specified accuracyProline Promag P 300 Endress+Hauser9 Flow characteristic values in SI unitsNominaldiameterRecommendedflowFacto ry full scale value(v ~ m/s)Current output full scalevalue 1)(v ~ m/s)Pulse value 1)(~ 2 pulse/s)Low flow cut off(v ~ m/s)


Related search queries