Proma operator 's Instructions Alliant Series Dental Units Document 9050784 Rev-A 09/11. Proma operator 's Instructions Alliant Series Dental Units Table of Contents Table of Contents Specifications Operating 1 Ambient Enlighten B. Storage & Shipping 1 Temperature +10 C to +40 C Electrical Input: 1 Humidity 30% to 75% Voltage 120 VAC. Phase 1. Technical 1 Atmospheric Frecuency 50 / 60Hz Power 15 VA. 1 Pressure Range 700hPa to Electrical Output: Replacement 2 1060 hPa Voltage 9 VAC. Care & 2 Storage & Shipping Current 1000mA. Power 9W. 2. Control Locations Selector Head: Ambient w/Pinch Control 3 Temperature -40 C to +70 C. Satelec SP Newtron Scaler w/Traditional Control 4 Humidity 10 to 95 RH. Electrical Input: w/Pinch Control Blocks - 5 Atmospheric Voltage 115 VAC. Phase 1. Flex Arm Counterbalance Pressure Range 7 to 10 psi Frecuency 50 / 60Hz (50 to 106 kpa) Power VA.

Alliant Series Dental Units Document 9050784 Rev-A 09/11 Proma Operator’s Instructions

Tags:

  Operator, Instructions, Royal, Mopar, Proma operator s instructions

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Proma Operator’s Instructions - Royal Dental Group

1 Proma operator 's Instructions Alliant Series Dental Units Document 9050784 Rev-A 09/11. Proma operator 's Instructions Alliant Series Dental Units Table of Contents Table of Contents Specifications Operating 1 Ambient Enlighten B. Storage & Shipping 1 Temperature +10 C to +40 C Electrical Input: 1 Humidity 30% to 75% Voltage 120 VAC. Phase 1. Technical 1 Atmospheric Frecuency 50 / 60Hz Power 15 VA. 1 Pressure Range 700hPa to Electrical Output: Replacement 2 1060 hPa Voltage 9 VAC. Care & 2 Storage & Shipping Current 1000mA. Power 9W. 2. Control Locations Selector Head: Ambient w/Pinch Control 3 Temperature -40 C to +70 C. Satelec SP Newtron Scaler w/Traditional Control 4 Humidity 10 to 95 RH. Electrical Input: w/Pinch Control Blocks - 5 Atmospheric Voltage 115 VAC. Phase 1. Flex Arm Counterbalance Pressure Range 7 to 10 psi Frecuency 50 / 60Hz (50 to 106 kpa) Power VA.

2 6. Electrical Output: Cuspidor 7 Classifications Voltage 24 VAC. Assistant Vacuum 8 Current A. Classification Power 26 W. Work Surface Height 8 of Equipment Class I. Dental Patient Water 9 Pneumatic Specifications: Degree of Protection Water Pressure Solids 10 against harmful Patient Bottle 35 psi ( Kpa). ingress of water Ordinary City Water 35 psi ( Kpa). Air Pressure Mode of Regulated 80 psi ( Kpa). Operation Intermittent Technical Support For Technical support and repair assistance, contact your local Proma dealer Proma 730 E. Kingshill Place Carson, CA 90746. Phone Fax Document 9050784 rev n/c 02/11. Replacement Parts Care & Disinfection To order supplies or replacement parts for the Alliant Series Dental unit, contact your local Proma dealer. Use Disposable Plastic Films and Foils Proma encourages the use of disposable films and Part Number Description foils on handles and surfaces commonly touched 50002129A Uni-Handpiece Holder Assembly w/Water Controls, Right with gloved hands.

3 This can reduce the need for 500021301 Uni-Handpiece Holder Assembly w/Water Controls, Left chemical surface disinfection and extend the life span and appearance of these surfaces. 50002400B Uni-Control Block Assembly 41150004 Amalgam Trap Assembly Do Not Soak Plastic Parts 4115006 Amalgam Trap Lid The useful life of many plastics may be greatly 92989 O-ring, Lid Amalgam Trap shortened by soaking in any disinfectant solution for unnecessarily long periods. 93013 HVE Valve Assembly 93014 Saliva Ejector Valve Assembly Cleaning your Proma Unit 93015 Lever, HVE Clean and disinfect the unit at beginning and end of 93018 Lever, Saliva Ejector workday and week. 50002210 Water Bottle, Quick Connect Assembly Proma approves the use of a mild soap and water 46188006 56 Handpiece Hose Assembly solution, applied with a soft cloth.

4 92751 Syringe Assembly 92982 Gasket, Quick Connect Water Bottle Unitized Handpiece Holders 9128600k One Litter Water Bottle Kit Proma also recommends the use of Soft Scrub R. 9132700k Two Liter Water Bottle Kit with Bleach to clean the handpiece cavity of the 20150022 Channel Tilt, Telescopic Arm holder. Apply cleaner to a soft cloth and rub the area 8257002 Absorbing Oil Collector Pad to be cleaned. 8030106 1/2-20 Hex Nut, Toggle Valve BIOTROL. 91032 Stainless Steel Tray Proma recommends Birex R. SE manufactured by 92451 Syringe Repair Kit Biotrol International. 92814 Foot Control Repair Kit 91462 Air Regulator Kit The outside surfaces may be cleaned with a moist 91463 Water Regulator Repair Kit (not dripping) soft towel soaked in any mild soap and water solution and squeezed dry. Wipe and dry with a soft towel. Do not use abrasive cleaners or rough paper towel which may scratch the molded surfaces.

5 After cleaning, wipe all surfaces with a gauze sponge moistened (not dripping) in a properly prepared diluted disinfectant. Warranty Proma warrants its product against defects in materials does not cover damages resulting from improper installa- and / or workmanship for five years from the date of shipment tion or maintenance, accident or misuse. Warranty is void from the factory. No other warranties are expressed or if product is not installed by an authorized Proma dealer. implied. No employee, representative or dealer is authorized NO OTHER WARRANTIES AS TO MERCHANTABILITY, to change this warranty in any way, or grant any other war- FITNESS FOR USE OR OTHERWISE ARE MADE. This ranty dealing with this product. Proma 's sole obligation under warranty gives specific legal right, and there may also be this warranty is limited to repair, replace, or modify the other rights which vary from state to state.

6 (Some states defective part or product, if, in its judgment, this is advisable. do not allow the exclusion or limitation of incidental or Labor and other costs for removal and reinstallation are not consequential damages, so the above exclusion may not included in this warranty. The buyer shall have no other apply.). remedy. (All special, incidental, and consequential damages are excluded.) Written notice of breach of warranty must be Proma will provide service advice and Instructions as given to Proma within the warranty period. The warranty required for repair or replacement of this product. Call for service. 2. Control Locations, Selector Head with Pinch Control Block 1 Master Air & Water ON / Off Toggle Opens and closes the air and water supply for the complete system. Exhausts air when turned off. Important: Shut off system by setting toggle to the off position each night before removing Patient Water Bottle, or when not in use.

7 2 Handpiece Coolant Water on / Off Toggle On / Off for handpiece water. Turn off for low speeds that normally do not require water coolant. 1 4. 3. 3 Handpiece Water Flush System 2. 6 6. Flushes handpieces with water. Remove handpiece 6. from selector and hold over basin or cuspidor bowl. Open fine mist controls fully. Pull forward for two 5. minutes before first patient. Ten seconds between 8. patients. Adjust fine mist controls. 4 Arm Lock/Release Momentary Valve Releases vertical arm travel lock. Push-in button to unlock arm and release button to lock. 5 6. 5 Handpiece Pressure Gauge Avoid exceeding manufacturer's recommended air pressure 30 to 35 psi for most high-speed handpieces. 10 9. 6 Drive Air Pressure Control Knobs Adjusts drive air pressure to the handpiece. Clockwise 7. decreases pressure, counterclockwise increases pressure.

8 Caution: Excess pressure damages handpiece bearings. 9 Oil Collection Jar Pad absorbs handpiece oil. Unscrew and empty jar and replace pad weekly. Order kit 9128100. 7 Coolant Water Fine Mist Control Knob (24 pads). Controls water coolant to handpieces. Counterclock- wise increases pressure and clockwise decreases pressure. 10 Coolant Air Adjustment Control Knob Adjusts coolant airflow to all handpieces. counter-clockwise increases pressure and 8 Coarse Water Control clockwise decreases pressure. Stops water dripping after foot control is released. Adjust to fine mist with fine mist controls fully opened. 3. Control Locations, Selector Head with Traditional Control Block 1 Master Air & Water ON / Off Toggle Opens and closes the air and water supply for the complete system. Exhausts air when turned off. Important: Shut off system by setting toggle to the off position each night before removing Patient Water Bottle, or when not in use.

9 2 Handpiece Coolant Water on / Off Toggle On / Off for handpiece water. Turn off for low speeds that normally do not require water coolant. 1 4. 3 6. 6 6. 3 Handpiece Water Flush System 2. Flushes handpieces with water. Remove handpiece from selector and hold over basin or cuspidor bowl. Open fine mist controls fully. Pull forward for two minutes before first patient. Ten seconds between 5. 8. patients. Adjust fine mist controls. 4 Arm Lock/Release Momentary Valve Releases vertical arm travel lock. Push-in button to unlock arm and release button to lock. 6. 5 Handpiece Pressure Gauge 5. Avoid exceeding manufacturer's recommended air pressure 30 to 35 psi for most high-speed handpieces. 10 9. 6 Drive Air Pressure Control Knobs Adjusts drive air pressure to the handpiece. Clock- wise decreases pressure, counterclockwise increases 7.

10 Pressure. Caution: Excess pressure damages handpiece bearings. 9 Oil Collection Jar Pad absorbs handpiece oil. Unscrew and empty jar and replace pad weekly. Order kit 9128100. 7 Coolant Water Fine Mist Control Knob (24 pads). Controls water coolant to handpieces. Counterclock- wise increases pressure and clockwise decreases pressure. 10 Coolant Air Adjustment Control Knob Adjusts coolant airflow to all handpieces. counter-clockwise increases pressure and 8 Coarse Water Control clockwise decreases pressure. Stops water dripping after foot control is released. Adjust to fine mist with fine mist controls fully opened. 4. Control Locations, Hygiene Selector Head with Pinch Control Block 1 Master Air & Water ON / Off Toggle Opens and closes the air and water supply for the complete system. Exhausts air when turned off.