Promag 55 PROFIBUS PA (BA) - Axon Automation

BA124D/06/ as of version:V (Device software)Operating InstructionsProline Promag 55 PROFIBUS PAElectromagnetic Flow measuring System8 Brief operating instructionsProline Promag 55 PROFIBUS PA2 Endress+HauserBrief operating instructionsThese brief operating instructions show you how to configure your measuring device quickly and easily:Safety instructionsPage 7 First of all, familiarize yourself with the safety instructions so that you can carry out the following working steps quickly and easily. Here you can find information about such topics as the designated use of the measuring device, operational safety and the safety icons and symbols used in the document. InstallationPage 13 The "Installation" section contains all of the necessary information for incoming acceptance, the installation conditions that have to be observed (orientation, installation site, vibrations etc.)

BA124D/06/en/12.07 71065432 Valid as of version: V 3.05.XX (Device software) Operating Instructions Proline Promag 55 PROFIBUS PA Electromagnetic Flow Measuring System

Tags:

  System, Flows, Measuring, Promag, Electromagnetic, Profibus, Promag 55 profibus pa, Promag 55 profibus pa electromagnetic flow measuring system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Promag 55 PROFIBUS PA (BA) - Axon Automation

1 BA124D/06/ as of version:V (Device software)Operating InstructionsProline Promag 55 PROFIBUS PAElectromagnetic Flow measuring System8 Brief operating instructionsProline Promag 55 PROFIBUS PA2 Endress+HauserBrief operating instructionsThese brief operating instructions show you how to configure your measuring device quickly and easily:Safety instructionsPage 7 First of all, familiarize yourself with the safety instructions so that you can carry out the following working steps quickly and easily. Here you can find information about such topics as the designated use of the measuring device, operational safety and the safety icons and symbols used in the document. InstallationPage 13 The "Installation" section contains all of the necessary information for incoming acceptance, the installation conditions that have to be observed (orientation, installation site, vibrations etc.)

2 , through to the actual installation of the measuring device, including information about seals, grounding and the required tightening torques for the compact and remote versions. WiringPage 38 The "Wiring" section describes the electrical connection of the measuring device and the connection of the remote version connecting cable. Additional topics of this chapter include: The specifications of the coil/signal cable and the fieldbus cable The terminal assignment The potential matching and degree of protection Display and operating elementsPage 58 The available display and operating elements of the local display and information on working with the function matrix are presented here. Operating programsPage 64 measuring device can be configured and operated using the local display and using operating programs from various manufacturers.

3 Basic configuration (device parameters, Automation functions)Page 69 can commission your measuring device quickly and easily, using the special "Quick Setup" menu. It enables you to configure important basic functions using the local display, for example display language, measured variables, units of measures following adjustment is to be made separately as necessary: Empty/full-pipe adjustment for empty pipe detection Page 96 ff. PROFIBUS interfacePage 78 the PROFIBUS interface. system integration and cyclic data transmissionUse of the device master files (GSD files) Page 81 data transmission Page 85 ff. Hardware settingsInformation about setting the hardware write protection, the device address, etc.

4 For: PROFIBUS PA Page 66 ff. Application-specific commissioningPage 71 the "Commissioning" Quick Setup, you have the option of starting the Quick Setup for Promag 55 PROFIBUS PABrief operating instructionsEndress+Hauser3!Note! Always start troubleshooting with the checklist on Page 101 if faults occur after commissioning or during operation. The routine takes you directly to the cause of the problem and the appropriate remedial measures. Customer-specific configurationPage 61 measuring operations necessitate additional functions that you can configure as necessary with the aid of the function matrix, and customize to suit your process parameters.!Note! All functions are described in detail, including the function matrix itself, in the Description of Device Functions manual (BA125D), which is a separate part of these Operating Instructions.

5 Data storagePage 73 configuration of the transmitter can be stored on the integrated T DAT data storage device.!Note! For timesaving commissioning, the settings stored in the T DAT can be transmitted: For equivalent measuring points (equivalent configuration) In the event of device/board operating instructionsProline Promag 55 PROFIBUS PA4 Endress+HauserQUICK SETUP "Commissioning"!Note! More detailed information on running Quick Setup menus, especially for devices without a local display, is contained in the "Commissioning" section. Page 69 1: Quick Setup for straightforward commissioningn30013001+++EEscE+ +EmopDeliver SettingsySelection pre-settingsActual Settings0402 UnitVolume FlowVolume FlowMass FlowQuitConfigure another unit?

6 NOYESUnitDensityValueDensityUnitTotalize rUnitTotalizerUnitMass FlowSelectionSystem units042007000400 Autom. Configurationof Display?NONOYESA utomatic parameterizationof the displayAnotherQuick Setup?Quick SetupcompleteCommissionLanguagePre-Setti ngQuick SetupHOME-POSITIONQS10022000 BProline Promag 55 PROFIBUS PATable of contentsEndress+Hauser5 Table of contents1 Safety instructions .. Designated use .. Installation, commissioning, operation .. Operational safety .. Return .. Notes on safety conventions and icons .. 82 Identification .. Device designation .. Nameplate of the transmitter .. Nameplate of the sensor .. Nameplate for connections .. Certificates and approvals.

7 Registered trademarks .. 123 Installation .. Incoming acceptance, transport and storage .. Incoming acceptance .. Transport .. Storage .. Installation conditions .. Dimensions .. Mounting location .. Orientation .. Inlet and outlet runs .. Vibrations .. Foundations, supports .. Adapters .. Nominal diameter and flow rate .. Length of connecting cable .. Installation .. Installing the Promag S sensor .. Installing the Promag H sensor .. Turning the transmitter housing .. Turning the local display .. Installing the wall-mount housing .. Post-installation check.

8 374 Wiring .. PROFIBUS PA cable specifications .. Cable type .. Maximum overall cable length .. Maximum spur length .. Number of field devices .. Bus termination .. Further information .. Shielding and grounding .. Connecting the remote version .. Connecting the sensor .. Cable specifications .. Connecting the measuring unit .. Connecting the transmitter .. Fieldbus connector .. Terminal assignment .. Potential equalization .. Standard case .. Special cases .. Degree of protection .. Post-connection check .. 565 Operation .. Quick operation guide .. Local display .. Display and operating elements.

9 Display (operating mode) .. Icons .. Brief operating instructions for the function matrix . General notes .. Enabling the programming mode .. Disabling the programming mode .. Error messages .. Type of error .. Error message type .. Operating options .. Operating program "FieldCare" .. Operating program "SIMATIC PDM" (Siemens) .. Device description files for operating programs .. PROFIBUS PA hardware settings .. Switching hardware write protection on and off .. Configuring the device address .. 676 Commissioning .. Function check .. Switching on the measuring device .. Quick Setup.

10 "Commissioning" Quick Setup menu .. "Communication" Quick Setup .. Data backup/transmission .. Configuration .. measuring solids content flow .. Advanced diagnostic functions .. Commissioning the PROFIBUS PA interface .. PROFIBUS PA system integration .. Device master file (GSD file) .. Selecting the GSD file in the measuring device .. Compatibility to the previous model Promag 35 .. Maximum number of writes .. PROFIBUS PA cyclic data transmission .. Block model .. Modules for cyclic data transmission .. Description of the modules .. Configuration examples with Simatic S7 HW-Konfig.