Example: biology

ProMinent beta Metering Pumps

ProMinent beta 1 ProMinent beta Metering Pumps The Drive UnitPump housingConstructed of fiberglass -rein-forced PPE plastic, with a NEMA4x enclosure rating to protectagainst corrosion, dust and driveThe drive unit houses a short-stroke solenoid with a maximumstroke length of " ( mm).It is equipped with a noise sup-pressing mechanism for quietoperation and has only one movingpart, the on pulse action, eachpulse generates a magnetic field inthe solenoid coil. This magneticfield moves the armature the end of the armature is thediaphragm. The diaphragm pushesinto the dosing head cavity forcingchemical out of the dischargeThe beta pump series is a solenoid-driven, diaphragm-type Metering pump featuring the following: Microprocessor based Capacity range - gph ( - 32 L/h) Continuous stroke length adjustment from 0 to 100% 10-setting stroke frequency adjustment from 10 to 100% Maximum stroke rate: 180 spm Repeatability +/- 2% when used according to operatinginstructions Liquid end materials: PP, PVC, Acrylic, PTFE, SS Auto degassing liquid ends High viscosity liquid ends External access to options 12-24 VDC low voltage optionProMinent solenoid-driven meteringpumps consist of two main compo.

Pr o Minent ® beta–1 ProMinent ® beta Metering Pumps The Drive Unit Pump housing Constructed of fiberglass-rein-forced PPE plastic, with a …

Tags:

  Fiberglass, Pumps, Bates, Metering, Prominent, Prominent beta metering pumps, 174 beta metering pumps

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ProMinent beta Metering Pumps

1 ProMinent beta 1 ProMinent beta Metering Pumps The Drive UnitPump housingConstructed of fiberglass -rein-forced PPE plastic, with a NEMA4x enclosure rating to protectagainst corrosion, dust and driveThe drive unit houses a short-stroke solenoid with a maximumstroke length of " ( mm).It is equipped with a noise sup-pressing mechanism for quietoperation and has only one movingpart, the on pulse action, eachpulse generates a magnetic field inthe solenoid coil. This magneticfield moves the armature the end of the armature is thediaphragm. The diaphragm pushesinto the dosing head cavity forcingchemical out of the dischargeThe beta pump series is a solenoid-driven, diaphragm-type Metering pump featuring the following: Microprocessor based Capacity range - gph ( - 32 L/h) Continuous stroke length adjustment from 0 to 100% 10-setting stroke frequency adjustment from 10 to 100% Maximum stroke rate: 180 spm Repeatability +/- 2% when used according to operatinginstructions Liquid end materials: PP, PVC, Acrylic, PTFE, SS Auto degassing liquid ends High viscosity liquid ends External access to options 12-24 VDC low voltage optionProMinent solenoid-driven meteringpumps consist of two main compo-nents: the pump drive unit and theliquid end.

2 The beta series offers twodrive (solenoid) sizes: beta/4 (BT4a)and beta/5 (BT5a). Operatingprinciples and options are identical,and both units offer maximumbackpressures up to 253 psig ( ). Capacity range for the beta/4 to 5 gph ( to 19 L/h); beta/5is to gph ( to 32 L/h).Feed rate is determined by strokelength and stroking rate: stroke lengthcan be varied from 0 to 100% with anadjustment ratio of 10:1. It is setmanually by the adjustment knobon the front of the rate can be adjusted in 10%increments between 10 and 100% viathe multifunction switch. This switch isalso used to select voltage-free On/Offexternal pulse contact, pump stop, ortest (for priming).CUTAWAY VIEW OF ProMinent BETA SOLENOID-DRIVEN Metering PUMP1 HOUSING2 LIQUID END3 DIAPHRAGM4 BACKPLATE5 SOLENOID6 SOLENOID COIL7 SOLENOID AXLE8 ARMATURE9 COVER10 STROKE ADJUSTMENTSCREW11 STROKE ADJUSTMENTAXLE12 STROKE ADJUSTMENTKNOB valve.

3 When the magnetic field isde-energized, a spring returns thearmature and diaphragm to theiroriginal position. This returnmovement draws chemical into thedosing head cavity through thesuction the event of a diaphragm rupture,the liquid end has a weep hole onthe bottom of the backplate todirect chemical out of the pump andaway from the solenoid. Anoptional diaphragm failure monitorcan be used to stop the pump andindicate a stroke-length adjusting mecha-nism is directly connected to thesolenoid. Adjustment results in anaccurate self-locking stroke lengthsetting. The DiaphragmThe diaphragm is constructed offabric-reinforced EPDM elastomerwith a plastic core and a PTFE-facing. It is chemically resistantagainst virtually all process fluidsand can be used over a widetemperature beta pump is designed with thenew-style convex diaphragm.

4 Thecurved shape contributes to moreprecise Metering and alleviatesstress placed on the diaphragm byreducing liquid end dead beta 2 Power SupplyThe beta Metering Pumps accept100-115, 200-230 or a universal 100-230 volt power supply +/- 10%,single phase, 50/60 Hz, with a factor. Performance isidentical whether operated on 50 Hzor 60 Hz power. The power cord EXTERNAL PANEL IN THE BASE OF THEPUMP ENABLES OPTIONAL RELAYS TO BEINSTALLED ON-SITE. The Liquid EndThe beta Metering pump liquid endsare available in five material versions: Polypropylene (PP) PVC (PC) Acrylic/PVC (NP) PTFE (TT) 316 Stainless steel (SS)Some liquid ends are interchangeablebetween the BT4a and BT5a (see tableon page 4).Options include a manual bleed valvefor easy priming and continuousbleeding of fluids that tend to off-gas(available with versions 1000-0713PP, NP and PC liquid ends).

5 Automatic degassing liquid ends areavailable for PP and NP versions(except 1000 and 0232). This new-style liquid end discharges from thecenter and degasses from the top toprevent air build-up in the viscosity PVDF liquid ends areavailable for pump versions 1005,0708, 0413, 0220, 1605, 1008, 0713,and 0420. Their Metering capacity is10-20% less than standard pumpversions and recommended viscosityis up to 3000 cPs. The HV liquid endsare not and discharge ports areequipped with double ball checkvalves for maximum repeatability. Relay OutputsFault annunciating relayFor low tank level (level switch),processor fault, and fuse/powersupply relayA contact closure is issued withevery pump stroke (contact duration150 ms). This allows a secondProMinent Metering pump to bepaced synchronously, or to totalizeflow with an external stroke ARE IDENTICAL ON THE BETA/4 ANDBETA/5 PUMPSSTROKE LENGTHADJUSTMENT KNOBFAULT INDICATOR (RED LED)WARNING INDICATOR(YELLOW LED)OPERATING STATUS (GREEN LED)MULTIFUNCTION SWITCHPOWER INPUTEXTERNAL CONTROLLEVEL SWITCH OUTPUT Fault IndicatorsThree LED lights indicate operationalstatus.

6 A green light flashes duringnormal operation; a yellow light warns oflow chemical; and a red light indicateslack of chemical or an operational two-stage level switch is needed tomaximize this end with bleed valveLiquid end without bleed valveAuto-degassing liquid endSUCTIONDISCHARGEAUTO-DEGASSINGSUCTION SUCTIONDISCHARGEDISCHARGEBLEEDVALVEA vailableRecognizedProMinent beta 3 Specifications: betaMaximum stroke " ( mm)Materials of constructionHousing: fiberglass reinforced PPED iaphragm:PTFE-faced EPDM with plastic coreLiquid end options:Polypropylene, PVC, Acrylic/PVC, PTFE, 316 SSEnclosure rating:NEMA 4X (IP 65)Motor insulation class:FPower supply:100-115 VAC, 200-230 VAC or 100-230 VAC, 1 phase, 50/60 Hz, +/- 10%;12-24 VDC or 24 VDC +/- 10%Check valves:Double ballRepeatability of the Metering :When used according to operating instructions, 2% under constantconditions and at minimum 30% stroke lengthPower cord:6 foot (2 m)Relay cable (optional):6 foot (2 m)Relay loadFault relay only (options 1 & 3):Contact load: 250 VAC, 2 A, 50/60 HzOperating life: > 200,000 switch functionsFault and pacing relayContact load: 250 VAC/DC, 2 A, 50/60 Hz(options 4 & 5):Operating life: > 200,000 switch functionsResidual impedance in ON-position (RDSOn): < 8 Residual current in OFF-position: <1 AMaximum current: < 100 mAMaximum voltage: 24 VDCS witch functions: 15x109 Contact closure: 100 ms (for pacing relay)Ambient temperature range:14 F (-10 C) to 113 F (45 C)Max.

7 Fluid operating temperatures:MaterialConstantShort TermAcrylic/PVC113 F (45 C)140 F (60 C)Polypropylene122 F (50 C)212 F (100 C)PVC113 F (45 C)140 F (60 C)PTFE122 F (50 C)248 F (120 C)316 SS122 F (50 C)248 F (120 C)PVDF149 F (65 C)212 F (100 C)Average power drain at maximumstroking rate (Watts) / currentdrain at pump stroke (Amps)BT4a:17W / A or 15 A (peak current for approx. 1 ms)BT5a:22W / A or 15 A (peak current for approx. 1 ms)Service :2 years on drive, 1 year on liquid endIndustry standards:UL recognized, CE available for and CanadaValve threads:NP, PP, PC, TT Versions: M20 x (provided with tubing adapters)Standard Production Test:All Pumps are tested for capacity at maximum pressure prior toshipmentMax. solids size in fluid: Pumps with 1/4" valves: 15 - Pumps with 1/2" valves: 50 Controlling contact (pulse):With voltage free contact, or with semiconductor sink logic control (NPN),not source logic (PNP).

8 With a residual voltage of <700 mV, the contactload is approximately mA at +5 VDC. (Note: Semiconductor contactsthat require >700 mV across a closed contact should not be used.) Pumpignores contacts exceeding maximum input rate, and will not contact duration:20 msRecommended Viscocity:max. 200 cPs for standard liquid endmax. 500 cPs for bleed valvemax. 50 cPs for auto-degassing Metering pumpsmax. 3000 cPs for high viscosityProMinent beta 4 Technical Data: betaSuction/DischargePumpCapacity at MaximumCapacity at 1/2 WeightVersionBackpressureBackpressureSuc tionStrokingConnectors**(higher x for SS)psig (bar)GPH (L/h)strokepsig (bar)GPH(L/h)strokeft.(m)spmincheslbs.(k g)BT4a1000145(10) ( ) (5) ( ) (6)1801/4 x 3/16 ( )1601253 ( ) ( ) ( ) ( ) (6)1801/4 x 3/16 ( )1602253 ( ) ( ) ( ) ( ) (6)1801/4 x 3/16 ( )1005145(10) ( ) (5) ( ) (6)1801/2 x 3/8 ( )0708101(7) ( ) ( ) ( ) (6)1801/2 x 3/8 ( )041358(4) ( ) (2) ( ) (3)1801/2 x 3/8 ( )022029(2) ( ) (1) ( ) (2)1801/2 x 3 ( )BT5a1605253 ( ) ( ) ( ) ( ) (6)1801/2 x 3/8 ( )1008145(10) ( ) (5) ( ) (6)1801/2 x 3/8 ( )0713101(7) ( ) ( ) ( ) (4)1801/2 x 3/8 ( )042058(4) ( ) (2) ( ) (3)1801/2 x 3/8 ( )0232*29(2) ( ) (1) ( ) (2)1801/2 x 3 ( )With auto-degassing liquid endsBT4a1601253 ( ) ( ) ( ) ( ) ( )1801/4 x 3/16 ( )1602253 ( ) ( ) ( ) ( ) ( )1801/4 x 3/16 ( )1005145(10) ( ) (5) ( ) ( )1801/2 x 3/8 ( )0708101(7) ( ) ( ) ( ) ( )1801/2 x 3/8 ( )041358(4)

9 ( ) (2) ( ) ( )1801/2 x 3/8 ( )022029(2) ( ) (1) ( ) ( )1801/2 x 3 ( )BT5a1605253 ( ) ( ) ( ) ( ) (3)1801/2 x 3/8 ( )1008145(10) ( ) (5) ( ) (3)1801/2 x 3/8 ( )0713101(7) ( ) ( ) ( ) ( )1801/2 x 3/8 ( )042058(4) ( ) (2) ( ) ( )1801/2 x 3/8 ( )Above capacities and suction lift refer to Pumps tested on water at 115 VAC, 60 Hz, and an ambient temperature of 70 F (20 C).Higher specific gravity fluids will reduce suction lift. Higher viscosity fluids will reduce ends for highly viscous media have 10-20% les Metering capacity and are not self-priming. Standard connectors are 1/2" MNPTor 5/8" hose barb. Positive suction recommended.* Not available with bleed valve.** SS versions use 1/4" female threads except models 0220, 0420, and 0232 which use 3/8" female threads. Liquid end materialsVersionLiquid EndSuction/Discharge valvesSealsValve ballsPPEP olypropylenePolypropyleneEPDMC eramicPPBP olypropylenePolypropyleneViton CeramicPCEPVCPVCEPDMC eramicPCBPVCPVCV iton CeramicNPEA crylicPVCEPDMC eramicNPBA crylicPVCV iton CeramicPVTPVDFPVDFPTFEC eramicTTTPTFE with carbonPTFE with CarbonPTFEC eramicSST316 Stainless steel316 Stainless SteelPTFEC eramicAuto-degassing type with Hastelloy C valve spring and PVDF valve is a registered trademark of DuPont Dow Elastomers.

10 Interchangeable liquid endsThe following pump versions have interchangeable liquid ends:BT4a 1005 and BT5a 1605BT4a 0708 and BT5a 1008BT4a 0413 and BT5a 0713BT4a 0220 and BT5a 0420 ProMinent beta 5 Identity code: beta Metering pumpsSeries:BT4abeta/ 4 version aBT5abeta/ 5 version aBT4aBT5aPump version:10001605*16011008*16020713*1005* 0420**Versions available with high viscosity liquid ends0708*02320413*0220*Liquid end materials:PPPolypropylenePCPVCNPA crylic/PVCPVPVDF (for high viscosity only)TTPTFESSSS BT4a 1602 NPB200UD010 000 Seal:EEPDM seals (PP, PC, NP)BViton seals (PP, PC, NP)TPTFE seals (PVDF, TT, SS)Liquid end version:0W/o bleed valve, w/o springs (TT, SS and version 0232 PP/PC)1W/o bleed valve, with springs (TT, SS and version 0232 PP/PC)2 With bleed valve, w/o springs (PP, PC, NP; except version 0232 PP/PC)3 Wtih bleed valve, with springs (PP, PC, NP; except version 0232 PP/PC)4W/o bleed valve, with springs (for high viscosity only)9 With auto-degassing (PP, NP - except versions 1000, 0232)Connection:0 Standard according to technical data61/2" x 3/8" tube fittingsLabeling:0 Standard, with logoElectrical connection ( 10%):M12-24 VDC (versions 1000-0220)N24 VDC (versions 1605-0232)U115-230 V, 50/60 HzCable and plug with 6 ft (2 m) power cord, single phase:AEuropean plugDN.


Related search queries