Directional Control Valves K(A)DG5V-5/7/8 & KDG5V-10, 1* Series, Two-Stage Models without Electrical Feedback ISO 4401 Sizes 05, 07,08 and 10 product has been designed and tested to meet specific standards outlined in the EuropeanElectromagnetic Compatibility Directive (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and93/68/EEC, article 5. For instructions on installation requirements to achieve effective protection levels, seethis leaflet, the Installation Wiring Practices for Vickers Electronic Products leaflet 2468 and leaflet 02-123931 Awhich is packed with every KA valve. Wiring practices relevant to this Directive are indicated byElectromagnetic Compatibility (EMC).5052/EN/1097/AVickers Proportional KDG5V-5/7/8/10 are solenoidoperated Directional controlnon-feedback type Proportional Proportional Directional controlvalves in which the main-stage spool ispositioned according to the output from anintegrally mounted Proportional ,solenoid-operated , pressure-reducingvalve.

B.1 Proportional Directional Control Valves K(A)DG5V-5/7/8 & KDG5V-10, 1* Series, Two-Stage Models without Electrical Feedback ISO 4401 Sizes 05, 07,08 and 10 ANSI/B93.7M-D07/08/09

Tags:

  Control, Eaton, Valves, Proportional, Directional, Proportional directional control valves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Proportional Directional Control Valves - Eaton

1 Directional Control Valves K(A)DG5V-5/7/8 & KDG5V-10, 1* Series, Two-Stage Models without Electrical Feedback ISO 4401 Sizes 05, 07,08 and 10 product has been designed and tested to meet specific standards outlined in the EuropeanElectromagnetic Compatibility Directive (EMC) 89/336/EEC, amended by 91/263/EEC, 92/31/EEC and93/68/EEC, article 5. For instructions on installation requirements to achieve effective protection levels, seethis leaflet, the Installation Wiring Practices for Vickers Electronic Products leaflet 2468 and leaflet 02-123931 Awhich is packed with every KA valve. Wiring practices relevant to this Directive are indicated byElectromagnetic Compatibility (EMC).5052/EN/1097/AVickers Proportional KDG5V-5/7/8/10 are solenoidoperated Directional controlnon-feedback type Proportional Proportional Directional controlvalves in which the main-stage spool ispositioned according to the output from anintegrally mounted Proportional ,solenoid-operated , pressure-reducingvalve.

2 Direction of main-spool traveldepends upon which of the two solenoidsof the pilot valve is energized and theamount of travel is dependent upon thecurrent input to the any intermediate position of the mainspool, a force balance exists between thecontrolled, reduced pilot pressure actingon the spool end and the opposingcentering spring, plus the action of flowforces. There is no electrical feedback ofthe main-stage spool range of Valves offers effective andeconomic solutions for applications havingrepetitive load conditions throughout eachoperating cycle, mold closure/openingin plastics molding sizes 5,7 & 8 are available withintegral and BenefitsDThese global products, manufacturedto world-class quality standards, aresold and serviced throughout Valves open up expandedapplication opportunities as a costeffective alternative to feedback-typeproportional and servo flexible design approachprovides a wide variety of matchingelectronic amplifiers, valve options,and spool Section ViewsKDG5V-10 shown with EX or X (With integral pilot pressure reducer)

3 KDG5V-7 shown without EX or X (Without integral pilot pressurereducer) of .. Features and .. Typical .. Functional .. Model .. Spool .. Operating .. Performance .. Installation .. Subplates, Connection Plates and Mounting .. Electrical .. Installation .. Application .. SymbolsABPTP ilot identified A / B according to Model Code reducermodule, see ModelCode type 2C shownXY*Internal plug shown, for external pilot supply (via port X).For internal pilot supply (from port P) plug is not fitted. Port X should be blocked at mounting interface, or otherwise plugged at subplate or manifold block. See Model Code .ZInternal plug shown, for external pilotdrain (via port Y).For internal pilot drain (via port T) plugis not fitted.

4 Port Y should be blockedat mounting interface, or otherwise plugged at subplate or manifold block. See Model Code . See also Pilot Drain Application *ZPBATPBATXYPABTbqSimplified symbolKDG5V models(Spool type 2 shown)Typical Schematic Symbol-Size 10 Typical Schematic Symbol-Sizes 5/7/87-pin plugPilot stage with integral amplifierPTB CodesManual overrideBlank =Plain overridesH=Water-resistant overridesZ=No overridesSpool/ spring arrangementC = Spool spring centeredSolenoid identityV = Solenoid A at port A end of pilot valve, solenoid B at B end. (Energizing A gives main-stage flow from port B; energizing B gives flow from port A): German A energized for main-stage flow from port A; solenoid B energized for main-stage flow from port B: USA ANSI ratingSee Spool Data , page B port flow rating (L/min) forasymmetric spoolsSpool metering typeN = Meter-in and meter-outFlow ratingSee Spool Data , page rating (L/min) for symmetricspools: A port flow rating (L/min) forasymmetric spools5 Electrical data and connection typePlug connector type to ISO 4400 (DIN 43650).

5 For coil characteristics see Operating Data table (page ):U-G= For use with amplifier with 12V DC supplyU-GP = For use with 12V powerU-H= For use with amplifier with 24V DC supplyU-HA = For use with 24V power plugU-HR = For use with 800 mA power supplyF-PD7 = 7-pin connector with plastic plug. See warning note below9 Pilot drainT=Internal pilot drainBlank =External pilot drainPilot supplyModels without integral, fixed pilotpressure reducer moduleE =External pilot supplyBlank=Internal pilot supplyModels with integral, fixed pilot pressurereducer moduleX = Internal pilot supplyEX = External pilot supply4 Spool typeSee Spool Data , page 2 =All ports blocked when spool centered 7 =Open P to A&B, 12 =All ports blocked when spool centered, regenerative function when spool energized33/133 =Bleed A and B to T when spool centeredPilot drain pressure1 =Standard(See Pilot Drain Application Notes,page )Mounting interface size(ISO 4401)

6 5 = NFPA D05, CETOP 5 7 = NFPA D07, CETOP 7 8 = NFPA D08, CETOP 810 = NFPA D10, CETOP 10 For system pressures less than 200 bar(2900 psi) the pilot pressure reducingmodule is system pressures above 200 bar(2900 psi) the pilot pressure reducingmodule must be number, 10 seriesSubject to change. Installation dimensionsunaltered for design numbers 10 to featuresEN47 used with P type coil connectionand Uniplug if not requiredModel SeriesK ProportionalA Integral amplifier, sizes 5 / 7 & 8 onlyD Directional valveG Subplate/manifold mounted5 Solenoid controlled/pilot operatedV Pressure rating 350 bar (5000 psi) on P, A & B ports12381013141516761134587691012111213 141516 Heading electrical flag symbolM= Features and options for pilot valve12 WarningTo conform to the EC Electromagnetic Compatibility directive (EMC) this KACG valve must be fitted with a metal7-pin plug.

7 The screen of the cable must be securely connected to the shell of the metal connector. A suitable IP67rated connector is available from Vickers, part no. 934939. Alternatively a non IP67 rated connector is available fromITT-Cannon, part 02 COM-E 14S A7 P. The plastic plug, part number 694534, is only suitable for use in asealed electromagnetic environment or outside of the European DataFor K(A)DG5V-8 Valves :33C250N170133C250N170 For K(A)DG5V-7 Valves :2C180N33C170N2C33 CFor K(A)DG5V-8 Valves :2C280N33C270 NAsymmetric SpoolsFigure preceding metering type designator, N ( 2C**N) is flow rating P-A, orA-T ( A port flow); figure after N (N**) is flow rating P-B, or B-T ( B port flow).For KDG5V-10 Valves :2C310N5502C550N31033C310N55033C55 0N3102C7C12C33C133C2C33C310 L/min (82 USgpm), A port flow550 L/min (145 USgpm), B port flow550 L/min (145 USgpm), A port flow310 L/min (82 USgpm), B port flow310 L/min (82 USgpm), A port flow550 L/min (145 USgpm), B port flow550 L/min (145 USgpm), A port flow310 L/min (82 USgpm), B port flowFull flowRestricted flowSpool SymbolsSimplified symbols including transientflow conditions (dotted line).

8 Spool Types and Flow RatingsSymmetric SpoolsFlow ratings for flow through P-A-B-T at Dp = 5 bar (72 psi) per flow path, P-A,or B-T. For other pressure drop values see Flow Gain curves on page L/min (24 USgpm)80 L/min (21 USgpm)180 L/min (48 USgpm)170 L/min (45 USgpm)280 L/min (74 USgpm)270 L/min (71 USgpm)550 L/min (145 USgpm)550 L/min (145 USgpm)550 L/min (145 USgpm)550 L/min (145 USgpm)550 L/min (145 USgpm)2C33 CFor KDG5V-10 Valves :2C550N7C550N12C550N33C550N133C550 NFor K(A)DG5V-5 Valves :2C90N33C80 NSpool codeMain stagespool symbolFlow rating70 L/min ( USgpm), A port flow45 L/min (12 USgpm), B port flow180 L/min (48 USgpm), A port flow100 L/min (26 USgpm), B port flow250 L/min (66 USgpm), A port flow170 L/min (45 USgpm), B port flow250 L/min (66 USgpm), A port flow170 L/min (45 USgpm), B port flow2C2C33C133 CFor K(A)DG5V-7 Valves .

9 2C180N100 For K(A)DG5V-5 Valves :2C70N452C2C33C33 CSpool codeMain stagespool symbolFlow ratingSpool type 33 CABPTABPTS pool type 133C, withtypical regenerative circuitABPTABPTABPTS pool type 7 CSpool type 12 CSpool type DataData is typical:With fluid at 36 cSt (168 SUS) and 50_C (122_F). Using recommended Vickers amplifier to drive KDG5V valvesInstallation and Start-up GuidelinesML-B-9046 Max. solenoid currentCoil resistanceCoil type:U-GU-GPU-HU-HAU-HRAt 20_C (68_F)Max. Coil inductance measured at 1000 Hz and 150 mVCoil type:U-GU-GPU-HU-HAU-HR4 mH6 mH19 mH55 mH51 mHHysteresisSize 5/7/8 Size 10"4% of rated max. flowSize 5/7/8<6% of rated max. flowSize 10 Repeatability:Size 5/7/8 Size 10<3%8%Relative duty factorContinuous rating (ED = 100%)Type of electrical protection, with electrical plugs fitted correctlyIEC 144 Class IP65 Electrical connectionISO 4400 (DIN 43650)Recommended drive amplifierVickers Eurocard type:EEA-PAM-520-A-14 (one ramp), or EEA-PAM-523-A-32(two ramps) Valves with Integral AmplifiersPower supply24V DC (21V to 36V including 10% peak-to-peak )max.

10 Current 3 ACommand signalInput impedance"10V DC47 k 7-pin plug connectorPin connections:ABCDEFG Power supply +vePower 0 VSignal 0V+ve voltage command signal ve voltage command signalMonitor outputProtective groundElectro-magnetic compatibility (EMC):Emission (10 v/m)Immunity (10 v/m)EN 50081-2EN 50082-2 Gain adjustment25 to 125%Factory set adjustmentsDeadband, gain, dither and offsetMonitor point signalOutput impedance0,5V per amp solenoid current10 k Power stage PWM frequency2 kHz nominalReproducibility, valve-to-valve (at factory settings):Flow gain at 100% command signal<3% of rated flowProtection:ElectricalMechanicalRever se polarity protectedIEC 144, Class IP65 Relative humidity65 to 85% at 20 to 70_C (68 to 158_F)Supporting products:Auxiliary electronic modules (DIN-rail mounting):EHA-CON-201-A-2* signal converterEHD-DSG-201-A-1* command signal generatorEHA-RMP-201-A-2* ramp generatorEHA-PID-201-A-2* PID CharacteristicsEXXData is typical with fluid at 36 cSt (168 SUS) and 50_C (122_F), using Vickersrecommended amplifier to driveKDG5V PressureFor full flow performance pilot pressurew45 bar (650 psi), :Pressure at port P for internal pilotsupply ( X or omit in model code).