Example: confidence

purlins, rails & eaves beams - Hi-Tech Steel Buildings

CI/SfB. (47) Nh2. October 2012. purlins , rails & eaves beams > design guide ms eaves beams . syste r ails floor cee l in n g s pur sheeti d ze & cee d ze purlins , rails & eaves beams Index About Steadmans .. 03 Zed and Cee Sheeting rails .. 19. Introduction .. 03 Sleeved 19. Specification .. 03 Butted system .. 19. 03 Double span system (brick restraint).. 19. 04 Sleeved rail system .. 20. Butted & double span rail 21. Zed and Cee section range .. 06. Typical brick restraint 21. Zed Purlin Systems .. 07. Sheeting rail sag-system requirements 22. Sleeved single span system .. 07. Sheeting rail sag 23. Sleeved double span 07. Horizontal wall cladding requirements .. 24. Heavy end-bay single span system .. 07. Fire Rated Boundary 25.

A Steadman & Son Limited (usually known as Steadmans) are one of the UK's leading manufacturers of roofing and cladding, supplying high quality cladding materials from

Tags:

  Rail, Beam, Roofing, Purlins, Rails amp eaves beams, Eaves

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of purlins, rails & eaves beams - Hi-Tech Steel Buildings

1 CI/SfB. (47) Nh2. October 2012. purlins , rails & eaves beams > design guide ms eaves beams . syste r ails floor cee l in n g s pur sheeti d ze & cee d ze purlins , rails & eaves beams Index About Steadmans .. 03 Zed and Cee Sheeting rails .. 19. Introduction .. 03 Sleeved 19. Specification .. 03 Butted system .. 19. 03 Double span system (brick restraint).. 19. 04 Sleeved rail system .. 20. Butted & double span rail 21. Zed and Cee section range .. 06. Typical brick restraint 21. Zed Purlin Systems .. 07. Sheeting rail sag-system requirements 22. Sleeved single span system .. 07. Sheeting rail sag 23. Sleeved double span 07. Horizontal wall cladding requirements .. 24. Heavy end-bay single span system .. 07. Fire Rated Boundary 25.

2 Heavy end-bay double span 07. Additional Details .. 26. Sleeved purlin 08. Typical Zed section details (Cee sections similar) . 26. Butted single span 08. Parapet framing .. 27. Butted purlin system .. 08. Valley beam details .. 28. Roof sag-system requirements .. 09. Door & window framing .. 29. Roof sag bar 10. Suspended services & point loads .. 30. Roof angle brace system .. 10. Suspended 31. Mono pitch roofs .. 11. Steep pitch 12 Detailing Information .. 32. Shallow pitch roofs .. 12 Zed purlin and rail hole punching details .. 32. Long roof slopes .. 13 Cee rail hole punching details .. 33. Curved roofs .. 13 Fire wall rail hole punching details .. 34. Tiled 14 Standard cleats for purlins & rails .. 35. Cantilever purlins .

3 15 Anti-sag system components .. 36. Cleats .. 37. eaves beams .. 16. Miscellaneous components .. 38. Sections .. 16. Custom sections .. 39. Typical eaves beam 17. Typical connections to column heads .. 17 Technical support .. 40. Connections between eaves beams References .. 41. and rail 18. purlins , rails & eaves beams 02. About Steadmans specification A Steadman & Son Limited (usually known as Steadmans) NBS Plus is a library of technical product information are one of the UK's leading manufacturers of roofing and written in NBS format, linked to NBS. cladding, supplying high quality cladding materials from clauses and clause guidance. our sites in England, Scotland and Northern Ireland. With NBS Plus, specifiers can select We offer total roofing and cladding solutions which we products quickly and accurately then drop deliver with our dedicated haulage fleet.

4 The product information directly into a specification. Our continuous investment programme and on-going NBS clauses for Zed, Cee and eaves beam sections and product development ensures we can provide high quality other Steadmans products are now available for NBS. products promptly and at competitive prices. subscribers. introduction Requirements This brochure contains details of our increased range of Zed, Cee and eaves beam sections and accessories. Zed, Cee and eaves beam sections are manufactured in a Section profiles and dimensions are included along with process certified to ISO 9001:2008. structural properties, detailing information and typical construction details. Installation warranty The new section range offers complete compatibility Steadmans offer an independent audit-based warranty for between Zed and Cee sections sizes.

5 Zed, Cee and eaves beam sections. The products are formed from hot dipped galvanised Steel The QA+ warranty, from Auditing Workmanship &. coil to BS EN 10346:2009 Fe E390G -Z275. Materials Ltd, provides pre-site and on-site quality inspections and audits to ensure the high standards of The sections are designed to BS EN 1993-1-3:2006 using a construction and finishing which will maximise service life combination of rational analysis and component testing. and reduce maintenance costs. A separate brochure containing load tables for the The QA+ warranty can be extended to a ten year insurance purlins , rails & eaves beams is also available from backed warranty covering defects arising from poor Steadmans upon request or as a download from our workmanship, defective materials and damage resulting website.

6 From design defects. Contact Steadmans for more Steadmans realise that our standard range will not meet all information about the warranties. requirements and therefore customer designed Zed, Cee and eaves beam sections can be manufactured along with individual designs for special applications. Our extensive stock of full width coils in various gauges and our capability to cut, fold and punch these materials allow us to offer solutions to almost all situations. Please consult Steadmans Sales Department for further details. purlins , rails & eaves beams 03. purlins , rails & eaves beams overview Sleeve eaves beam Roof cladding Wall cladding Brickwork Cee-section door framing purlins , rails & eaves beams 04. Gable cleader angle Purlin Zed-section rail Push-fit sag bar eaves brace Cee-section rail Diagonal tie rail strut Brickwork purlins , rails & eaves beams 05.

7 purlins , rails & eaves beams zed and cee section range A E. Y Y. Table 01: Zed & Cee profile dimensions C F. Section Zeds Cees Depth A B C D E F. Depth Depth x x 140,170 60 54 16 20 62 13 x x 200 70 64 16 20 70 15. Yna 240 75 67 18 22 74 17. 300 95 87 21 25 95 19. D F. Xna B Dimensions in mm Xna Y. Y. Table 02: Standard Zeds - 390N/mm2 Steel grade Section Wt Area Zxx Zyy Ixx lyy Rx Ry Po Qs xna yna Mc (kg/m) (cm2) (cm3) (cm3) (cm4) (cm4) (mm) (mm) (N/mm2) (mm) (mm) (kNm). 14014 14015 14016 14018 14020 17014 17015 17016 17018 17020 17025 20014 20015 20016 20018 20020 20025 24015 24016 24018 24020 24025 24030 30020 30025 30030 Table 03: Standard Cees - 390N/mm2 Steel grade Section Wt Area Zxx Zyy Ixx lyy Rx Ry Po Qs xna yna Mc (kg/m) (cm2) (cm3) (cm3) (cm4) (cm4) (mm) (mm) (N/mm2) (mm) (mm) (kNm).

8 14014 14015 14016 14018 14020 17014 17015 17016 17018 17020 17025 20014 20015 20016 20018 20020 20025 24015 24016 24018 24020 24025 24030 30020 30025 30030 purlins , rails & eaves beams 06. zed purlin systems Four structural systems are available, the Sleeved System, Double-Span Sleeved System, Heavy End-Bay System and the Butted System. These systems allow for a flexible and efficient range of solutions to roofing supports for a wide variety of cladding types, the major features of which are outlined below. Sleeved single span system This is the traditional system of single bay-length sections with sleeves at all penultimate supports and at alternative internal supports. The system may be used with all types of claddings and roof pitches, within the limitations given in this manual.

9 Minimum number of spans is 2 and the maximum span is Details are on page 32. Sleeved double span system Sleeves are provided at all penultimate supports and are staggered at internal bays. The advantage is a reduced number of erection components when compared with the Sleeved System. Note that maximum section length is restricted to 15m for transport and handling reasons. Consideration should be given to handling and erection sequence when utilising the double-span sections. Minimum number of spans is 4 and the maximum span is Details are on page 32. Heavy end-bay single span system This is a highly efficient sleeved-system, with sleeves at all supports thus allowing a form of continuous beam design. Inner bay sections and sleeves are thinner than at the end bay thus allowing an economic solution for long Buildings .

10 Sleeves at penultimate supports are of the same thickness as the outer bay purlin section. Minimum number of spans is 4 and maximum span is Details are on page 32. Heavy end-bay double span system Sleeves are provided at all penultimate supports and are staggered at internal bays. The advantage is a reduced number of erection components. Inner bay sections and sleeves are thinner than at the end bay thus allowing an economic solution for long Buildings . Sleeves at penultimate supports are of the same thickness as the outer bay purlin section. Minimum number of spans is 4. and maximum span is Details are on page 32. purlins , rails & eaves beams 07. purlins , rails & eaves beams zed purlin systems sleeved purlin system Single/double span lengths Refer to pages 04 - 05 for overview of system and sleeve requirements.


Related search queries