253 Parker HannifinHydraulic Filter Division thecatastrophicresults of watercontaminationEliminate water from thehydraulic systemThe PVS Series Portable PurificationSystems, available in several Models ,is used to draw water contaminatedfluid out of a system, remove thewater content and return the clean fluid to the reservoir. Maximumflow 170 l/min (PVS2700). Reducethe catastrophic results of Features: PVS draws water contaminated fluid out of a system. Removes water, air and particulate content and returns the clean fluid to the reservoir. Maximum flow 170 l/min (PSV2700). Reduce the catastrophic results of water Series - Models 185,600, 1200, 1800 and 2700 Portable Purification SystemsContact Information:Parker HannifinHydraulic Filter Division EuropeEuropean ProductInformation CentreFreephone: 00800 27 27 5374(from AT, BE, CH, CZ, DE, EE, ES,FI, FR, IE, IT, PT, SE, SK, HannifinHydraulic Filter Division is one of the most common and destructivecontaminants in a fluid system.)

253 ParkerHannifin HydraulicFilterDivisionEurope FDHB500UK. Reduce the catastrophic results of water contamination Eliminatewaterfromthe hydraulicsystem

Tags:

  Series, 1080, Model, 2010, 2007, Pvs series models 185, 1800 and 2700

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of PVS Series - Models 185, 600, 1200, 1800 and 2700

1 253 Parker HannifinHydraulic Filter Division thecatastrophicresults of watercontaminationEliminate water from thehydraulic systemThe PVS Series Portable PurificationSystems, available in several Models ,is used to draw water contaminatedfluid out of a system, remove thewater content and return the clean fluid to the reservoir. Maximumflow 170 l/min (PVS2700). Reducethe catastrophic results of Features: PVS draws water contaminated fluid out of a system. Removes water, air and particulate content and returns the clean fluid to the reservoir. Maximum flow 170 l/min (PSV2700). Reduce the catastrophic results of water Series - Models 185,600, 1200, 1800 and 2700 Portable Purification SystemsContact Information:Parker HannifinHydraulic Filter Division EuropeEuropean ProductInformation CentreFreephone: 00800 27 27 5374(from AT, BE, CH, CZ, DE, EE, ES,FI, FR, IE, IT, PT, SE, SK, HannifinHydraulic Filter Division is one of the most common and destructivecontaminants in a fluid system.)

2 When watercontaminates a system, it can cause seriousproblems such as:Corrosion by etching metalFluid breakdown, reduction of lubricatingproperties, additive precipitation, and oiloxidationReduced dielectric strengthAbrasive wear in hydraulic componentsContaminated oil is drawn into the Parker portablepurification system by a vacuum of 25 In/Hg. Theoil passes through the in-line low watt densityheater/s where the oil is heated to an optimumtemperature of 66 C (150 F).The oil then enters the distillation column where it isexposed to the vacuum through the use of dedicateddispersal elements. This increases the exposedsurface area of the oil and converts the water toa vapor form, which is then drawn through thecondenser by the vacuum pump. The vapour returnsto water and drops into the condensate holding tank- this can then be drained off at a later water-free oil falls to the bottom of the vacuumchamber and is passed through a final particulateremoval filter by a heavy duty lube oil dry oil re-enters the reservoir/system via theoutlet SeriesPortable Purification SystemsEffects of Water ContaminationPrinciples of Operation%.

3 03%.04%.005%Fluid typeHydraulic fluidLubrication fluidTransformer fluidPPM30040050 Typical saturation pointsFree water occurs when oil becomes saturatedand cannot hold any more water. This water isusually seen as cloudy oil or puddles of waterat the bottom of an oil reservoir. Water which isabsorbed into the oil is called dissolved higher temperatures, oil has the ability to holdmore water in the dissolved stage due to theexpansion of oil molecules. As the oil cools, thisability reverses and free water will appear wherenot visible before. In addition to temperature, fluidtype also determines the saturation point for yoursystem (see chart above).% Water In Oil050100150200250% Bearing Life Remaining255 Parker HannifinHydraulic Filter Division for PVS Portable Purification SystemsPaper mills- Dryer lubrication- Hydraulic- Compressor lubrication- CalendersSteel mills- Bearing lubrication- Continuous casters- Press roll lubricationPower generation- Turbine oil- Transformer oil- EHC systemsIndustrial/aerospace- Test stands- Machine toolsAir CooledCondenserCondensateholding tankVacuum pumpCaster wheelsForklift guidesLiquid level sightglassLow watt densityheaterSelf diagnosingcontrols include.

4 ProgrammablethermostatReverse pole switch/phase fail% RH displayVariable flow circuitMoisture sensorCondensate holding tankCompact sizeForklift guidesLifting eyesProgrammable thermostatAutomatic operationReverse pole switch/phase failHigh temperature safety circuitCircuit breakers utilised inelectrical panelAvailable with EPR seals andstainless steelSolid state heater contacterAllows oil to heat to requiredtemperature quicklyReal-time water content indicationCaptures removed water/solventsLarge enough to provide long serviceintervalSmallest envelope in the industryEase of portabilityProvides safe and secure method tolift unitMaintains oil within 1 CPrevents overheating oilUnattended useChange motor rotation for different powersource locationsShuts down heater if primarycontacters failOil can never exceed 120 C (250 F)No fuses to replaceSimple diagnosticsPhosphate ester compatibleLonger more reliable service lifeStarts removing water quicklyIndicates when safe water content levelis obtainedEliminate potential hazard of exhaustingto atmosphereReduced maintenance costsFits through doorways and downnarrow aislesIncreased useEmployee safetyEasily transportedUnattended operationIncreases oil lifeReduced labour costsIncreased running timeFlexibility, less maintenancePrevents incorrect rotationPrevents system damageWorker safetyFewer spare parts, increased uptimeReduced maintenanceSpecifically designed for applicationReduced downtimeFeaturesAdvantagesBenefits256 Parker HannifinHydraulic Filter Division SeriesPortable Purification SystemsTypical PerformancePVS (Vacuum dehydration)

5 Compared to other technologiesCentrifuge units Removes free water only; has difficultybreaking stable emulsions; larger envelope dimensions butlower flows; higher initial and operating units Have limited water removal capability dueto absorbing material; only removes air ingressed particles;expensive compared to the volume of water units Removes free water only; has difficultybreaking stable emulsions; does not work well in viscous fluids(>23cSt); much larger in size compared to particulateISO cleanliness code*14/13/10 attainableWaterRemoves 100% of free water,80-90% of dissolved 100% of free air,90% of dissolved 100% of free gases,90% of dissolved gases.* When utilising 2Q mediaTank size227 litres (50 gallons)Run time62 minutesParker modelPVS 600 ( l/min)Water content (ppm) Start: 10,000 PPM ( )Stop: 50 PPM( )Contamination level Start: ISO 21/18/16 Stop: ISO 16/14/11 StartStop0 1000 2000100003000 4000 5000 6000 7000 8000 9000020406080100120 Reservoir Size (Gallons)Total HoursPVS185 PVS600 PVS 1200 PVS 1800 PVS 2700 Reservoir Size (Litres)35000030000250002000015000100005 000 Estimated Water Removal Time5000 ppm ( ) to 150 ppm ( )257 Parker HannifinHydraulic Filter Division 185 Portable Purification SystemsSpecificationFlow rate:19 lpm ( gpm).

6 Height:1651mm (65 ). ( ). ( ). kg (650 lbs).Seal material:Fluorocarbon (EPR opt.).Condensate ltrs ( gals).Dispersal operating ltrs ( gals).Vacuum (max):25 (max):108 cSt (500sus) cSt (2150 sus) pressure (max) bar (60 psi).Ports:3/4 JIC (male) JIC (male) (full load amps):15-41 amps.(Depending on voltage used).PVS 185 flow diagramHeaterStandard CorelessParticulate 80CN-22QE (2 micron) 936716Q5QE (5 micron) 936717Q10QE (10 micron) 936718Q20QE (20 micron) 936719 QOption CorelessParticulate IL8-32QE (2 micron) 933734Q5QE (5 micron) 933612Q10QE (10 micron) 933735Q20QE (20 micron) 933736 QCorelessDisposable933180(Coalescing)Pac ked tower933553(Cleanable)Replacement elements258 Parker HannifinHydraulic Filter Division rate:38 lpm ( gpm). ( ). (44 ). (61 ). kg (900 lbs).

7 Seal material:Fluorocarbon (EPR opt.).Condensate ltrs ( gals).Dispersal operating ltrs ( gals).Vacuum (max):25 (max):108 cSt (500sus) cSt (2150 sus) pressure (max) bar (60 psi).Ports:1 JIC (male) JIC (male) (full load amps):24-38 amps.(Depending on options& voltages).PVS 600 flow diagramPVS 600 Portable Purification SystemsStandard CorelessParticulate 80CN-22QE (2 micron) 936716Q5QE (5 micron) 936717Q10QE (10 micron) 936718Q20QE (20 micron) 936719 QOption CorelessParticulate IL8-32QE (2 micron) 933734Q5QE (5 micron) 933612Q10QE (10 micron) 933735Q20QE (20 micron) 933736 QCorelessDisposable933180(Coalescing)Pac ked tower933553(Cleanable)Replacement elements259 Parker HannifinHydraulic Filter Division 1200 Portable Purification SystemsSpecificationFlow rate:76 lpm ( gpm).

8 Height:1651mm (65 ). (44 ). (61 ). kg (1550 lbs).Seal material:Fluorocarbon (EPR opt.).Condensate ltrs ( gals).Dispersal operating ltrs ( gals).Vacuum (max):25 (max):108 cSt (500sus) cSt (2150 sus) pressure (max) bar (60 psi).Ports:11/2 NPTF JIC (male) (full load amps):30-48 amps.(Depending on options& voltages).PVS 1200 flow diagramDispersalDisposable933180(coalesc ing)Packed tower933553(cleanable)Coreless IL8-302QE933734Q05QE933612Q10QE933735Q20 QE933736 QReplacement elements260 Parker HannifinHydraulic Filter Division 1800 Portable Purification SystemsSpecificationFlow rate:114 lpm (25 gpm).Height:1651mm (65 ). (42 ). ( ). kg (2550 lbs).Seal material:Fluorocarbon (EPR opt.).Condensate ltrs ( gals).Dispersal operating ltrs ( gals).Vacuum (max):25 (max):108 cSt (500sus) cSt (2150 sus) pressure (max) bar (60 psi).

9 Ports:2 NPTF JIC (male) (full load amps):40-65 amps @ 460 (coalescing)Packed tower933553(cleanable)Coreless IL8-302QE933734Q05QE933612Q10QE933735Q20 QE933736 QReplacement elementsPVS Specification Worksheet - Section 1 Note: The following information will be required before a PVS order can be Fluid .. Specific ViscosityMin .. SUS/cSt F/ SUS/cSt F/ SUS/cSt F/ C4. Contamination level Current ISO level ___ /___ /___Desired PPM level ___ /___ /___5. Water concentration Current ISO PPM Suction Head Positive/Negative .. Operating distance ..8. System fluid operating temperature: .. F/ CIs there a cooler?..9. Operating environment air temperature: (air cooled model )Min .. F/ CMax .. F/ F/ C261 Parker HannifinHydraulic Filter Division 2700 Portable Purification SystemsSpecificationFlow rate:170 lpm ( gpm).

10 Height:1651mm (65 ). (42 ). ( ). kg (2550 lbs).Seal material:Fluorocarbon (EPR opt.).Condensate ltrs ( gals).Dispersal operating ltrs ( gals).Vacuum (max):25 (max):108 cSt (500sus) cSt (2150 sus) pressure (max) bar (60 psi).Ports:3 NPTF NPTF (full load amps):50-70 amps @ 460 (coalescing)Packed tower933553(cleanable)Coreless IL8-302QE933734Q05QE933612Q10QE933735Q20 QE933736 QReplacement elementsPVS Specification Worksheet - Section 210. Water supply temperature: (liquid ring model )Min .. F/ CMax .. F/ F/ C11. Operating environment above/below sea level:.. Voltage Options: 230 Vac, 3p, 60Hz (185,600)380 Vac, 3p, 50Hz (185,600, 1200, 1800,2700)460 Vac,3p,60Hz (185,600, 1200, 1800,2700)575vac, 3p 60Hz (185,600, 1200, 1800,2700)13. Available amperage:..14. System volume:..15. Special requirements.