Quicklub Lubrication Systems - Lincoln Industrial

Quicklub Lubrication Systems8 Electric grease Pumps 203 SeriesP203 Series PumpThese pumps are electrically operated and are used in progressive-type automated Lubrication Systems . The proven and reliable P203 pump has been designed to develop high operating pressures allowing it to supply NLGI #2 grease in most ambient temperatures . Versatile, compact and ecomomical, this pump can be enhanced with several options including an integrated controller, low-level monitoring and system monitoring. Special configurations are available upon : Customer must furnish a 12- or 24-volt power source.

Electric Grease Pumps—203 Series ... The proven and reliable P203 pump has been designed to develop high operating pressures allowing it to supply NLGI #2 grease in most ambient temperatures. Versatile, compact and ecomomical, this pump can be enhanced with several options ... Operating Temperature Range: Min. -13°F / -25°C / Max. 158°F ...

Tags:

  High, System, Temperatures, Grease, Lubrication, Lubrication system

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Quicklub Lubrication Systems - Lincoln Industrial

1 Quicklub Lubrication Systems8 Electric grease Pumps 203 SeriesP203 Series PumpThese pumps are electrically operated and are used in progressive-type automated Lubrication Systems . The proven and reliable P203 pump has been designed to develop high operating pressures allowing it to supply NLGI #2 grease in most ambient temperatures . Versatile, compact and ecomomical, this pump can be enhanced with several options including an integrated controller, low-level monitoring and system monitoring. Special configurations are available upon : Customer must furnish a 12- or 24-volt power source.

2 * Protected from water sprayed in all directions.** Single 6mm element standard; to increase pump output, add one or two additional element(s) #600-26876-2 and relief valve #270864.** Pressure relief valve included with these Specifications* Can be set for either minutes or grease Pumps Without Integrated ControllerModel SpecificationsModel RequirementsReservoir VDC - 2 VDC - Amps644-46278-324 VDC - 2 grease Pumps with Integrated On/Off ControllerOutput/Min Per Element**:.171 cu. in. / ccLubricant Outlet: " NPT (F)Max.

3 system Operating Pressure:5000 psig / 350 barEnclosure Rating:IP6K9K*Operating Temperature Range:Min. -13 F / -25 C / Max. 158 F / 70 CReservoir Capacity:2-, 4-, 8- or 15-liter **Reservoir Fill Method:By grease fittingPressure Relief Valve:4000 psi, +/- 250 psi / 276 bar, +/- 17 barModel RequirementsInterval Timer SettingReservoir CapacityOn Time* (2 minute increments) Off Time (1 hour increment) VDC / Amps2 minutes30 minutes1 hour15 VDC / 2 Lubrication Systems9 Electric grease Pumps 203 SeriesElectric grease Pumps with Low-Level Sensor and Integrated Controller for Feedback MonitoringNote.

4 Do not use pump without pressure relief valve.* Protected from water sprayed in all Specifications*These 644- pumps do not come with the pressure relief valve. It must be ordered separately and is recommended. The " NPT adapter (304-19614-1) is also not included and must be ordered separately, if required. None of the above pumps come with the proximity switch. This must be ordered NLGI #2 grease (depending on temperature) to divider RequirementsInput:12 VDC @ amps, 24 VDC @ 2 amps 94 - 265 VAC (50 to 60 Hz)Enclosure Rating:IP6K9K *Interval Between Lube Cycles:Min.

5 4 minutes / Max. 15 hoursPump cu. / Connection: " NPT (F)Reservoir Capacity:2-, 4-, 8- or 15-liter **Maximum Recommended Operating Pressure:5000 psi / 350 barLubricant:Greases NLGI grade 2 (depending on operating temperature and type of lubricant)Temperature Range:-13 F to 158 F / -25 C to 70 CPressure Relief Valve:4000 psi, +/- 250 psi / 276 bar, +/- 17 barModel SettingsReservoir CapacityInterval Between Lube Cycle Between Lube Cycle Time +SV24 VDC4 - 601 -155 or 302122 +SV24 VDC4 - 601 -155 or 304244 +SV24 VDC4 - 601 -155 or 308488 1694822 LDL +SV24 VDC4 - 601 - 155 or 308488 16644-40987-2 +SV24 VDC4 - 601 -155 or 3015 915 30644-40821-6* VDC4 - 601 -155 or 302122 4644-40843-8* VDC4 - 601 -155 or 304244 8644-40822-8* VDC4 - 601 -155 or 308488 16644-40873-1* VAC 4 - 601 -155 or 308488 16 Quicklub

6 Lubrication Systems10 Electric grease Pumps 203 SeriesElectric grease Pump with RemoteLinc Technology Easily interfaces with OEM and aftermarket telematics Systems Allows users to: - Remotely monitor and detect low lubricant levels and system faults. - Reduce cost by receiving immediate, real-time alerts when lubricant is low or the system is in SpecificationsModel Capacity94223-1212 VDC2L94423-1212 VDC4L94823-1212 VDC8L9422324 VDC2L9442324 VDC4L94423 LDL24 VDC4L (Lidless)9482324 VDC8L94823 LDL24 VDC8L (Lidless)9492324 VDC15L94223-AC94-265 VAC2L94423-AC94-265 VAC4L94823-AC94-265 VAC8 LElectrical RequirementsInput:12 VDC @ amps, 24 VDC @ 2 amps94-265 VAC (50 to 60 Hz)Enclosure Rating:IP6K9K*Interval Between Lube Cycles:Min.

7 4 minutes / Max. 15 hoursPump cu. / Connection:1/8 NPT (F)Reservoir Capacity:2-, 4-, 8- or 15-liter**Maximum Recommended Operating Pressure:5000 psi / 350 barLubricant:Greases NLGI grade 2 (depending on operating temperature and type of lubricant)Temperature Range:-13 F to +158 F / -25 C to +70 CPressure Relief Valve:4000 psi, 250 psi / 276 bar, 17 barNone of the above pumps come with a proximity switch. This must be ordered Lubrication Systems11 Electric grease Pumps 203 Series203 AC ModelsThis VAC pump automatically adjusts to handle a variety of electrical supply voltages (between 94- and 265-volt, 50 to 60 Hz.)

8 * Contact Lincoln for 15-liter reservoir Specifications (UL) in the description refers to UL-approved, CSA-certified with -A+SV come complete with the NPT adapter and pressure relief Voltage:94 - 265 VAC, 3 AmpsOperating Temperature:-13 to 158 F / -25 to 70 CNumber and Element Size:1 - 6mmReservoir Capacity:2-, 4-, 8- or 15-liter *Output per Minute:Approx. cc / cu. in. per :Greases up to NGLI #2/Oil with at least 40 cStMax. Operating Pressure:5076 psi / 350 barModel or OilLow level controlPrinted circuit board644-46073-5 (UL)-A+SV 2 liter grease NoYes644-46173-4 (UL)-A+SV 4 liter grease NoYes644-46173-5 UL)-A+SV 4 liter OilYes Yes644-46073-6 (UL)-A+SV2 liter grease NoNo644-46173-6 (UL)-A+SV4 liter grease YesNo644-46173-8 (UL)-A+SV4 liter OilYesNo644-46173-7 (UL)-A+SV4 liter grease NoNo644-46174-2 (UL)-A+SV 8 liter grease Yes Yes644-46174-4 (UL)

9 -A+SV8 liter grease YesNoQuicklub Lubrication Systems12P 203P 203P 203P 203P 203P 203242842 XXXXYXNNNNLLBOBOBO112111K6 KRK5K6K7K62424122424241A2A1A1A1A1A161517 101510141016M13HV13V20V10 Reservoir Design2 = 2 l transparent plastic reservoir4 = 4 l transparent plastic reservoir8 = 8 l transparent plastic reservoir15 = 15 l transparent plastic reservoirX = reservoir for greaseY= reservoir for oilN = standard designL = low-level controlwithout designation = standard reservoir (2 l)BO = filling from topFL = flat type reservoir (for 2l, no low level)Pumping Element1 - 3 number of elementsPiston Type - Piston Diameter (selection see page 20)K5 - 5 mmK6 - 6 mmK7 - 7 mmKR adjustable - 7 mmB7 - 7 mm (outlet same as K5)S7 - 7 mm (food industry)Operating Voltage12 VDC or 24 VDC (DC motor)AC = 94 - 265 VAC (47 - 63 HZ) with 24 VDC motorNumber of Connection Possibilities1A = 1 connector (left), power supply 11A = 1 connector (left)

10 , power supply 21A = 1 connector, power supply left + illuminated push button for additional Lubrication , low level 3, C2A = 2 connectors, power supply (left) 1, + illuminated push button for additional Lubrication , low-level (right) 1, C (V10 - V13, V20 - V23, H)2A = 2 connectors, power supply (left) + illuminated push button for additional Lubrication , low-level (left) )3, C and piston detector (right) 4 (M08 - M23)Type of Connection1 = square type connector (DIN 43650, type A) 15 = bayonet plug, 4/3 , DIN 72585-1 2 (V10-V13, V20-V23, H)6 = bayonet plug, 7/5 , DIN 72585-13) (M08-M23)7 = bayonet plug, 7/6 , DIN 72585-1 3 (V10-V13, V20-V23)