Transcription of R-78 -0 - RECOM Power
1 Efficiency up to 97%, no need for heatsinks Features Pin-out compatible with LM78XX linears Very low profile - 32V Wide input range DC/DC Converter Switching .. Short circuit protection, thermal shutdown Low ripple and noise Regulator IEC/EN60950-1 certified Positive to negative converter Description Amp The R-78xx-Series high efficiency switching regulators are ideally suited to replace 78xx linear regultors and are pin compatible. The efficiency of up to 97% means that very little energy is wasted as SIP3. heat so there is no need for any heat sinks with their additional space and mounting costs. Low ripple and noise figures and short circuit, overload and over-temperature protection round off the specifications of Single Output this versatile converter series. This is fully certified to EN55032 EMC Standard and for IEC/EN-60950-1 + AM2 Safety.
2 Selection Guide Part Input Output Output Efficiency Number Voltage Range Voltage Current @ min Vin @ max. Vin [VDC] [VDC] [A] [%] [%]. - 30 (1) 73 63. - 32 82 71. - 32 87 77. (2) - 32 91 81. - 32 94 86. - 32 95 88. 11 - 32 96 92. 15 - 32 12 97 94. 18 - 32 15 97 95. IEC/EN60950-1 certified Notes: EN55032 compliant Note1: Output can be unstable with Vin>30 VDC. Note2: Refer to Transient Response on page I-3. Model Numbering Output Voltage Output Current REV.: 5/2019 I-1. DC/DC Converter Series Specifications (measured @ Ta= 25 C, 10% minimum load, unless otherwise stated). BASIC CHARACTERISTICS. Parameter Condition Min. Typ. Max. Absolute Maximum Input Voltage 34 VDC. Quiescent Current nom. Vin= 24 VDC 5mA 7mA. Internal Power Dissipation Minimum Load (3) 0%. Internal Operating Frequency 280kHz 330kHz 380kHz 20 MHz BW, without output - 20mVp-p 30mVp-p capacitor 9 - 30mVp-p 40mVp-p Output Ripple and Noise 15mVp-p 20mVp-p 20 MHz BW (4).
3 - 25mVp-p 35mVp-p Absolute Maximum 1 second start up, no external components 220 F. Capacitive Load <1 second start up + diode protection circuit 6800 F. Notes: Note3: Operation under no load will not harm the converter, but specifications may not be met A minimum load of 6mA is recommended Note4: Measurements are made with a 100nF MLCC across output (low ESR). Efficiency vs. Vin (full load) Ripple vs. Vin (full load). 100 50 15 Vout 90 45 12 Vout 9 Vout 80 40 5 Vout 70 35. Efficiency [%]. Ripple [mV]. 60 30 50 25. 40 15, 12 Vout 20. 30 9 Vout 15. 5 Vout 20 10. 10 5. 0 0. 0 5 10 15 20 25 30 34 0 5 10 15 20 25 30 34. Input Voltage [VDC] Input Voltage [VDC]. Efficiency vs. Load (max. Vin) Ripple vs. Load (nom. Vin). 100 50 15 Vout 12 Vout 90 45. 9 Vout 80 40 5 Vout 70 35. Efficiency [%]. Ripple [mV]. 60 30 50 25. 40 15 Vout 20. 30 12 Vout 15.
4 5 Vout 20 10. 10 5. 0 0. 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100. Output Load [%] Output Load [%]. continued on next page REV.: 5/2019 I-2. DC/DC Converter Series Specifications (measured @ Ta= 25 C, 10% minimum load, unless otherwise stated). Efficiency vs. Load (min. Vin) Ripple vs. Load (min. Vin). 100 50 15 Vout 45 12 Vout 90. 9, 80 40 5 Vout 70 35. Ripple [mV]. Efficiency [%]. 60 30. 50 25. 40 20. 15, 12 Vout 30 15. 5 Vout 20 10. 10 5. 0 0. 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100. Output Load [%] Output Load [%]. REGULATIONS. Parameter Condition Value Output Accuracy 100% load typ / max. - typ. / max. Line Regulation low line to high line, 100% load 9V - typ. / max. - typ. / max. Load Regulation 10% to 100% load 9V - typ. / max. 100% <-> 50% load 75mV typ. Transient Response (5).
5 100% <-> 10% load 100mV max. Notes: Note5: The requires Vin> to meet the Transient Response specifications PROTECTIONS. Parameter Condition Value Short Circuit Protection (SCP) continuous, automatic recovery Short Circuit Input Current nom. Vin= 24 VDC +Vin +Vin +Vout +V. 60mA. out max. GND. Optional Diode Protection Circuit Optional Protection 1: Optional Protection 2: Add a blocking diode to Vout if GND GND. current can flow backwards into the output, as this can damage the +Vin +Vin +Vout +Vout +Vin +Vin +Vout +Vout=. converter when it is powered down. GND GND. +Vout - The diode can either be fitted across the device if the source is low impedance or fitted in series GND GND GND GND. with the output (recommended). +Vin +Vin +Vout +Vout=. Application example: GND. +Vout - Driving a high capacitive load +Vin +Vin +Vout +Vout GND. GND GND.
6 6800 F. GND GND. REV.: 5/2019 I-3. DC/DC Converter Series Specifications (measured @ Ta= 25 C, 10% minimum load, unless otherwise stated). ENVIRONMENTAL. Parameter Condition Value Operating Temperature Range with derating (see graph) -40 C to +85 C. Maximum Case Temperature +100 C. Temperature Coefficient Thermal Impedance , vertical 70K/W. Operating Altitude 2000m Operating Humidity non-condensing 95% RH max. Pollution Degree PD2. MTBF according to MIL-HDBK-217F, +25 C 26163 x 10 hours 3. Derating Graph 100. 80. Output Power [%]. 60. 40. 20. 0. -40 0 20 40 60 80 100. 71 85. Ambient Temperature [ C]. SAFETY AND CERTIFICATIONS. Certificate Type (Safety) Report / File Number Standard IEC60950-1:2005, 2nd Edition + Am 2:2013. Information Technology Equipment, General Requirements for Safety 1603123. EN60950-1:2006 + Am 2:2013. EAC TP TC 004/2011.
7 RoHs 2+ RoHS 2011/65/EU + AM2015/863. EMC Compliance Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment - with external filter EN55032, Class A and B. Emission requirements (see filter suggestion below). ESD Electrostatic discharge immunity test Contact 6kV EN61000-4-2, Criteria A. Radiated, radio-frequency, electromagnetic field immunity test 3V/m EN61000-4-3, Criteria A. Fast Transient and Burst Immunity EN61000-4-4, Criteria A. Immunity to conducted disturbances, induced by radio-frequency fields 3V EN61000-4-6, Criteria A. Power Magnetic Field Immunity 50Hz, 3A/m EN61000-4-8, Criteria A. continued on next page REV.: 5/2019 I-4. DC/DC Converter Series Specifications (measured @ Ta= 25 C, 10% minimum load, unless otherwise stated). EMC Filter Suggestion according to EN55032. L1 +Vin +Vin +Vout +Vout GND.
8 C1 C2. GND GND. Component List Class A Component List Class B. MODEL C1 C2 L1 MODEL C1 C2 L1. 10 F F H choke 10 F F H choke 100V MLCC 100V MLCC RLS-397 100V MLCC 100V MLCC RLS-567. Notes: Note6: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice DIMENSION AND PHYSICAL CHARACTERISTICS. Parameter Type Value case non- conductive black plastic, (UL94 V-0). Material potting silicone, (UL94 V-0). PCB FR4, (UL94 V-0). Package Dimension (LxWxH) x x Package Weight typ. Dimension Drawing (mm). embossed logo Marking Pin Connections Pin # Single 1 +Vin 2 GND. 3 +Vout Tolerance: + Recommended Footprint Details Top View 1 2 3 1 2 3. Bottom View REV.: 5/2019 I-5. DC/DC Converter Series Specifications (measured @ Ta= 25 C, 10% minimum load, unless otherwise stated). INSTALLATION AND APPLICATION.
9 Positive to Negative Converter C1 and C2 are required and should be fitted close to the converter pins. +Vin 1 3. 2 Maximum capacitive load including C2 is 220 F. C1 C2. -Vout Pin Connections Pin # Negative Positive GND GND 1 +Vin +Vin 2 -Vout GND. 1 2 3 3 GND +Vout +Vin 1 3. 2. Selection Guide - NegativeC1 Output C2. Part Input Output -Vout Output Efficiency External Capacitor Number Voltage Range Voltage Current @ min Vin @ max. Vin C1 C2 (7). GND [VDC] [VDC] [A]. GND [%] [%]. - 28 68 67 10 F/35V 22 - 28 71 70 10 F/50V 22 2. - 28 +Vout 75 76 10 F/50V 22 1 3. - 28 77 80 10 F/50V 22 - 28 79 84 10 F/50V 22 F/10V. - 26 81 86 10 F/50V 10 F/10V. - 18 87 89 10 F/50V 10 F/16V. - 18 -12 87 90 10 F/50V 10 F/25V. - 18 -15 87 81 10 F/50V 10 F/25V. Notes: +Vin 1 3. Note7: Maximum Capacitive 2 Load including C2 is 220 F. C1 C2. -Vout Dual Output (two Converters) with Negative GND.
10 Output GND. +Vin 1 3. 2. C1 C2. -Vout GND GND. 2. 1 3 +Vout continued on next page REV.: 5/2019 I-6. DC/DC Converter Series Specifications (measured @ Ta= 25 C, 10% minimum load, unless otherwise stated). Standard Application Circuit +Vin +Vin +Vout +Vout GND. C1. F~10 F*. +Vin GND +Vin +Vout +Vout GND. GND. +Vin +Vin +Vout +Vout * Input capacitor required if Vin>26 VDC ( F)6800 F. or if the supply is a battery GND. or other low impedance source ( F~10 F). Capacitor should be electolytic or MLCC with 6800 F. low ESR ( 1 ). GND GND. GND GND. High Efficiency, Isolated, Dual Unregulated Output DC/DC Converter (1:1). +Vin +Vin +Vout +Vout DC/DC Converter (1:1). GND. +Vin +Vin +Vout +Vout Com C1 GND C2. Com -Vout GND C1 C2. C1, C2: optional GND -Vout - Isolated dual outputs C1, C2: optional - Wide input range to 34V. - Isolated dual outputs - Wide input range to 34V.