R410A Split Series OWNER'S MANUAL - Daikin

R410A Split SeriesMODELFTXV25AV1 FTXV35AV1 FTXV50AV1 FTXV60AV1 RXV25AV1 RXV35AV1 RXV50AV1 RXV60AV1 OWNER'S MANUALE nglishDisposal requirementsYour product and the batteries supplied with the controller are marked with this symbol. This symbol means that electrical and electronic products and batteries shall not be mixed with unsorted household waste. For batteries, a chemical symbol can be printed beneath the symbol. This chemical symbol means that the battery contains a heavy metal above a certain concentration. Possible chemical symbols are: Pb: lead (> )Do not try to dismantle the system yourself: the dismantling of the product, treatment of the refrigerant , of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation. Units and waste batteries must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring correct disposal, you will help to prevent potential negative consequences for the environment and human health.

and use only the specified refrigerant (R410A). The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury. • During installation, attach the refrigerant piping

Tags:

  Refrigerant, Split, Piping, Refrigerant piping

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of R410A Split Series OWNER'S MANUAL - Daikin

1 R410A Split SeriesMODELFTXV25AV1 FTXV35AV1 FTXV50AV1 FTXV60AV1 RXV25AV1 RXV35AV1 RXV50AV1 RXV60AV1 OWNER'S MANUALE nglishDisposal requirementsYour product and the batteries supplied with the controller are marked with this symbol. This symbol means that electrical and electronic products and batteries shall not be mixed with unsorted household waste. For batteries, a chemical symbol can be printed beneath the symbol. This chemical symbol means that the battery contains a heavy metal above a certain concentration. Possible chemical symbols are: Pb: lead (> )Do not try to dismantle the system yourself: the dismantling of the product, treatment of the refrigerant , of oil and of other parts must be done by a qualified installer in accordance with relevant local and national legislation. Units and waste batteries must be treated at a specialized treatment facility for re-use, recycling and recovery. By ensuring correct disposal, you will help to prevent potential negative consequences for the environment and human health.

2 Please contact the installer or local authority for more NoticesSafety 1 Parts Name .. 3 Installation NoticeInstallation dimension diagram .. 4 Tools for installation .. 5 Selection of installation 5 Requirements for electric connection .. 6 InstallationInstallation of indoor unit .. 7 Installation of outdoor pumping ..15 Leakage detection ..15 Check after installation ..16 Test and operationTest operation ..16 AttachmentConfiguration of connection pipe ..17 Pipe expanding method ..18 Screen Operation GuideButtons on remote to icons on display to buttons on remote controller ..20 Introduction to functions of combination buttons ..23 Operation guide ..24 Replacement of batteries in remote controller ..24 Emergency and Maintenance ..25 MalfunctionMalfunction analysis .. Precautions The precautions described herein are classified as WARNING and CAUTION. They both contain important information regarding safety.

3 Be sure to observe all precautions without fail. Meaning of WARNING and CAUTION noticesWARNING ..Failure to follow these instructions properly may result in personal injury or loss of ..Failure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances. The safety marks shown in this MANUAL have the following meanings: After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air conditioner and take care of it with the aid of the operation MANUAL . The English text is the original instruction. Other languages are translations of the original sure to follow the instructions. Be sure to establish an earth connection. Never attempt. WARNING Ask your dealer or qualified personnel to carry out installation not attempt to install the air conditioner yourself.

4 Improper installation may result in water leakage, electric shocks or fire. Install the air conditioner in accordance with the instructions in this installation installation may result in water leakage, electric shocks or fire. Be sure to use only the specified accessories and parts for installation to use the specified parts may result in the unit falling, water leakage, electric shocks or fire. Install the air conditioner on a foundation strong enough to withstand the weight of the foundation of insufficient strength may result in the equipment falling and causing injury. Electrical work must be performed in accordance with relevant local and national regulations and with instructions in this installation MANUAL . Be sure to use a dedicated power supply circuit of power circuit capacity and improper workmanship may result in electric shocks or fire. Use a cable of suitable not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.

5 Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal connections or connections or securing of wires may result in abnormal heat build-up or fire. When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires so that the control box lid can be securely positioning of the control box lid may result in electric shocks, fire or over heating terminals. If refrigerant gas leaks during installation, ventilate the area gas may be produced if the refrigerant comes into contact with fire. After completing installation, check for refrigerant gas gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater, stove or cooker. When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air, and use only the specified refrigerant ( R410A ).

6 The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage and even injury. During installation, attach the refrigerant piping securely before running the the compressor is not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury. During pump-down, stop the compressor before removing the refrigerant the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed, causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury. Be sure to earth the air not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.

7 Be sure to install an earth leakage to install an earth leakage breaker may result in electric shocks or fire. Do not touch any electronic component or terminal when the machine is running, stopping or has been powered off for less than 30 minutes to prevent the risk of electric shock!2 English The operating temperature range (outdoor temperature) is 18 - 43 C for cooling and -7 - 24 C for heating Do not install the air conditioner at any place where there is a danger of flammable gas the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out. While following the instructions in this installation MANUAL , install drain piping to ensure proper drainage and insulate piping to prevent drain piping may result in indoor water leakage and property damage. Tighten the flare nut according to the specified method such as with a torque the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.

8 Make sure to provide for adequate measures in order to prevent that the outdoor unit be used as a shelter by small animals making contact with electrical parts can cause malfunctions, smoke or fire. Please instruct the customer to keep the area around the unit clean. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial and household use by lay persons. Sound pressure level is less than 70 dB(A). NOTE: Motor ground only applies to the iron shell motor. This appliance is not intended for use by persons, including children, with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their shall be supervised to ensure that they do not play with the side DB/WB( C)Outdoor side DB/WB( C)Maximum cooling32/2343/26 Maximum heating27/-24/18 Working temperature range3 EnglishParts NameSLEEPTIMERLIGHTX-FANMODESAVE+-FANSWI NG ON/OFFTURBOair inletpanelfilteraux.

9 Buttonhorizontal louverair outletdisplayremote controllerheatingindicatorreceiverwindow powerindicatorcoolingindicatorIndoor Unitair inlethandleair outletOutdoor Unit4 EnglishInstallation dimension diagramDrainage pipeAt least 250cmAt least 15cmAt least 50cmAt least 50cmAt least 30cmAt least 300cmAt least 200cmSpace to the obstructionSpace to the obstructionSpace to the obstructionSpace to the ceilingSpace to the floorSpace to the obstructionSpace to the obstructionAt least 30cmAt least 15cmAt least 15cmSpace to the wallSpace to the wallSpace to the wall5 EnglishTools for installationSelection of installation location1 Level meter2 Screw driver3 Impact drill4 Drill head5 Pipe expander6 Torque wrench7 Open-end wrench8 Pipe cutter9 Leakage detector10 Vacuum pump11 Pressure meter12 Universal meter13 Inner hexagon spanner14 Measuring tape Please contact the local agent for installation. Don t use unqualified power :Basic requirementIndoor unitInstalling the unit in the following places may cause malfunction.

10 If it is unavoidable, please consult the local dealer:1. The place with strong heat sources, vapors, flammable or explosive gas, or volatile objects spread in the The place with high-frequency devices (such as welding machine, medical equipment).3. The place near coast The place with oil or fumes in the The place with sulfureted Other places with special The appliance shall not be installed in the There should be no obstruction near air inlet and air Select a location where the condensation water can be dispersed easily and won't affect other Select a location which is convenient to connect the indoor unit and near the power Select a location which is out of reach for The location should be able to withstand the weight of indoor unit and won't increase noise and The appliance must be installed above floor7. Don't install the indoor unit right above the electric Please try your best to keep away from fluorescent unit1.