RADOX TENUIS-TW 600V MM multi core - HONOVA

40123 HUBER+SUHNER Railway productsRADOX TENUIS-TW 600v MM multi coreConductor according to EN 50306-2 Number of conductors 2 .. Cross section mm2 Voltage rating 600/1000 V AC 900/1500 V DCTemperature range 50 to +120 CComposition of cable1. Cores TENUIS-TW 600v M colours: white, numbered and green-yellow further colours on request2. Separator tape3. Sheath RADOX EM 104 colour: blackCharacteristics and specialities Complies with the technical requirements of EN 50306 particularly low temperature high level of oil and fuel resistance High level of thermal resistance Broad product rangeApplication Typical applications include carriage wiring, terminal boxes, power supply to various systems and ground connections inside railway rolling stock at fixed or sporadic moving installations.

HUBER+SUHNER Railway products 41 RADOX® TENUIS-TW 600V MM multi core Construction Conductor Core Cable Conductor resistance Fire load Weight Item no. mm2 D nom. mm D nom. mm D mm R 20 max. Ω/km

Tags:

  Multi, Core, Radox, 600v, Unite, Tenuis tw 600v mm multi core, Radox tenuis tw 600v mm multi core

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of RADOX TENUIS-TW 600V MM multi core - HONOVA

1 40123 HUBER+SUHNER Railway productsRADOX TENUIS-TW 600v MM multi coreConductor according to EN 50306-2 Number of conductors 2 .. Cross section mm2 Voltage rating 600/1000 V AC 900/1500 V DCTemperature range 50 to +120 CComposition of cable1. Cores TENUIS-TW 600v M colours: white, numbered and green-yellow further colours on request2. Separator tape3. Sheath RADOX EM 104 colour: blackCharacteristics and specialities Complies with the technical requirements of EN 50306 particularly low temperature high level of oil and fuel resistance High level of thermal resistance Broad product rangeApplication Typical applications include carriage wiring, terminal boxes, power supply to various systems and ground connections inside railway rolling stock at fixed or sporadic moving installations.

2 Guidelines for selection and the installation are described in the standards EN 50355 and EN protection on railway vehiclesDIN 5510-2hazard level1, 2, 3, 4EN 45545-2 GOST 31565 (equivalent to GOST R 53315)NF F 16 -101class, categoryC / F0, int. A1, A2, B / ext. A1, A2, BNFPA 130 UNI CEI 11170-3 For further technical details please refer to our data +SUHNER Railway productsRADOX TENUIS-TW 600v MM multi coreConstructionConductorCoreCableConduc tor resistanceFire loadWeightItem mmDnom. mmD mmR20 max. mCablekg/100 m2 x x x x x x 2 x x 2 x x x x x x x x x x x x x G x x G x G x x x x x G x G x x : (earth) = green-yellowMM: insulation and sheath material designation according to EN 50306-1