Indoor General PurposeRayzerTMModular led lighting SystemFEATURES & SPECIFICATIONSINTENDED USEP rovides task or accent lighting in commercial, retail, hospitality and residential applications. Ideal for use under and over cabinets, display cases, task lighting , office lighting , coves and utility/work aluminum construction in a low-profile design. Frosted acrylic diffuser and continuous row of LEDs provides even illumination. ELECTRICALLink up to of modular system to one transformer (required, sold separately).

RayzerLED Modular Lighting System INSTALLATION DIAGRAM Note: Fixture includes 1 3/8" end row connector, 18” linking cord, mounting clips for flush or 30º mounting, and screws.

Tags:

  Lighting, Led lighting, Rayzer

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Rayzer - LED Lighting, Controls and Daylighting …

1 Indoor General PurposeRayzerTMModular led lighting SystemFEATURES & SPECIFICATIONSINTENDED USEP rovides task or accent lighting in commercial, retail, hospitality and residential applications. Ideal for use under and over cabinets, display cases, task lighting , office lighting , coves and utility/work aluminum construction in a low-profile design. Frosted acrylic diffuser and continuous row of LEDs provides even illumination. ELECTRICALLink up to of modular system to one transformer (required, sold separately).

2 Fixtures can be linked end-to-end with the included end row connector (1-3/8" spacing) or 18" linking cord). 3 , 24 and 121 connector cords may also be purchased separately for use between fixtures. Can be plugged in or direct-wired (splice box and 24" connector cord required for direct-wiring).OPTICSLEDs have a 50,000 hour L70 rated life. Provides a warm color temperature at 3000K, with 95 when used with the optional step dimmer (sold separately).INSTALLATIONAll mounting hardware included. Mounting clips allow for quick & easy installation.

3 Can be flush mounted or angled at 30 using the provided clips. All configurations tested to IES LM79 listed to US and Canadian safety standards. WARRANTY5-year limited warranty. Complete warranty terms located at: : Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 C. Specifications subject to change without INDOOR RAZC atalog NumberNotesTypeAccessories /Replacement Parts1,2 RAZTRANS24 12024v transformer - 120v power source, includes 5' cord and plug and 24" connector cord (for linking to first fixture)RAZTRANS24 MVOLT24v transformer - Multi-Volt power source, includes integrated direct-wire junction box and 24" connector cord (for linking to first fixture)

4 RAZDIMStep dimmer with remote touch pad, 10' cord length on remote touchpadRAZ CC121121 Linking cord (fixture to fixture)RAZ CC2424 linking cord (fixture to fixture)RAZ CC33 linking cord (fixture to fixture)R A Z LV CCLow voltage linking cord (cord to cord), to connect multiple linking cordsRAZ ERCEnd row connector (fixture to fixture, 1 3/8" fixture spacing, 1 connector per pack)RAZ PHDP ower hub distributor, allows for additional fixture runRAZ INLS26In-line power switch (transformer to linking cord, 26" cord length)UCD JBSplice box - white (required for 120V direct wire)UCD JB BLSplice box - black (required for 120V direct wire)UC ERC2424 connector cord - white (required for 120V direct wire for splice box to transformer connection)UC ERC24 BL24 connector cord - black (required for 120V direct wire for splice box to transformer connection)

5 Series1,2 LengthColor temperatureCRIF inishRAZR ayzer low profile LED undercabinet9IN9" nominal12IN1' ' nominal24IN2' nominal30K3000K90 CRI>90(blank)Brushed nickelORDERING INFORMATIONFor shortest lead times, configure products using bolded options. Example: RAZ 12IN 30K 90 CRIN otes 1 Link up to of modular system to one Transformer is required for "12"18"24"Lumens (3000K):324434630958 Watts (3000K) per watt:41434852 Length:9 -1/4 (2 3. 5)12-1/4 ( )18 -1/4 (4 6 .4)24-1/4 ( )Width:1-1/4 ( )1-1/4 ( )1-1/4 ( )1-1/4 ( )Height:1/2 ( )1/2 ( )1/2 ( )1/2 ( )All dimensions are inches (millimeters) unless otherwise indicated.

6 Weights are pounds (kilograms). Rayzer LED Modular lighting SystemFull photometric data report available within 2 weeks from request. Consult INDOOR: One Lithonia Way Conyers, GA 30012 Phone: Fax: 2010-2019 Acuity Brands lighting , Inc. All rights reserved. Rev. 07/01/19 Rayzer LED Modular lighting SystemINSTALLATION DIAGRAMNote: Fixture includes 1 3/8" end row connector, 18 linking cord, mounting clipsfor flush or 30 mounting, and InOptional6 power cord included with transformerRequired for direct-wireinstallationUCD JB (white)UCD JB BL (black)Link up to of xtures(not including linking cords)Includes 6 power cord for plug ininstallation and 24 linking cord toconnect thetransformer tothe rst stick24 Volt Transformer(required, sold separately)Splice Box and 24 Connector Cord (optional)Splice Box.

7 UC ERC24 R12 (white)UC ERC24 BL (black)24 Connector Cord:Connects the transformer to thelinking cordIn-Line Power Switch (optional)Use to link xtures end-to-endEnd Row Connector (optional)Allows for versatile wiringPower Hub Distributor (optional)Step Dimmer(optional)Use to link around corners or for widerspacing between xtures18 Linking Cord (included)Use to link xtures around corners or forwider spacing between xtures3 Linking Cord - Fixture-to-Fixture (optional)Use to connect 2 linking cords3 Linking Cord - Cord-to-Cord (optional)

8 121 and 24 Linking Cord Available (optional)Direct-WireFlush and 30 mounting clips are used with xtures, power hub distributor and touch INDOOR: One Lithonia Way Conyers, GA 30012 Phone: Fax: 2010-2019 Acuity Brands lighting , Inc. All rights reserved. Rev. 07/01/19