Example: stock market

RCI200 - Remote Control

In 11 inEstablished Leaders in Valve ActuationRCI200 scotch yoke Actuators For Quarter-Turn in 11 inRemote Control Actuators - Quality Controlled QualityRCI200 actuators are manufactured under strict quality Control in accordance with ISO 9001. They are all marked with CE, and comply with ATEX standards. Certified suitable for use at SIL 2 & SIL 3 as a single device in accordance with ICE 61508. The larger volumes are certified with Pressure Equipment Directive (PED).EfficiencyThe RCI200 with its scotch - yoke design gives at least 50% more torque in the end positions over most rack & pinion designs offered by our design, engineering and materials used in the RCI200 construction ensure opti-mum performance even in the hardest of environments.

8.5 in × 11 in Remote Control Range RCI200 Specifications The Remote Control RCI200 Series actuator features a modern scotch yoke mechanism for high starting and ending torques in a

Tags:

  Mechanisms, Scotch, Yoke, Scotch yoke mechanism

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of RCI200 - Remote Control

1 In 11 inEstablished Leaders in Valve ActuationRCI200 scotch yoke Actuators For Quarter-Turn in 11 inRemote Control Actuators - Quality Controlled QualityRCI200 actuators are manufactured under strict quality Control in accordance with ISO 9001. They are all marked with CE, and comply with ATEX standards. Certified suitable for use at SIL 2 & SIL 3 as a single device in accordance with ICE 61508. The larger volumes are certified with Pressure Equipment Directive (PED).EfficiencyThe RCI200 with its scotch - yoke design gives at least 50% more torque in the end positions over most rack & pinion designs offered by our design, engineering and materials used in the RCI200 construction ensure opti-mum performance even in the hardest of environments.

2 Since the company was founded in 1961, Remote Control has become the standard for excellence in the field of valve and damper automation for the oil, gas, power, water, and waste treatment industries around the established leaders in actuation technology, we owe our success to a commitment to quality at every stage, and at every level, of Remote Control s the heart of the company is an exceptional workforce of highly trained, forward thinking engineers, technicians, and sales support staff. Each play a crucial role in maintaining Remote Control s unrivaled reputation for innovation, reliability and first class after sales several fluid power actuator lines and additional electric actuators available, we are able to offer creative solutions and design systems for virtually any Remote Control for your operational or safety application requirements.

3 We will work with you from conception, to design, to in 11 inRemote Control Range RCI200 SpecificationsThe Remote Control RCI200 Series actuator features a modern scotch yoke mechanism for high starting and ending torques in a very compact package. The RCIO Series have adjustable stops in both directions for 5 sizes offering great flexibility. The spring return actuator features a spring module with the spring(s) safely contained in an epoxy powder coated housing offering maximum corrosion resistance. Our pistons are guided in two places with reinforced Teflon bearings which insure positive alignment and long seal life.

4 Pressure Range (Working) 30-145 PSI continuous RCI210-240 30-116 PSI continuous RCIO250-280 (87 max. on RCIO88)Torque Output: Up to 67,000 In-LbsTemperature Range Standard: -4 F to +175 F High: +32 F to +300 F Low: -40 F to +140 F Arctic: -52 F to +140 FStroke 90 3 (both directions on RCIO only)Media Dry or lubricating air, non corrosive gas, water, or light hydraulic oilConstruction Suitable for indoor or outdoor installationBottom Mounting ISO 5211/DIN 3337 (excluding RCIO88)Top/Solenoid Mounting VDI/VDE 3845 (NAMUR)Warranty 3-Years up to 2 million cycles for RCI210-RCIO260 & 1 million cycles for RCIO270-RCIO88 (subject to proper use and maintenance)

5 In 11 inTechnical DataOptional FinishesFeatures WeightsMaterials of ConstructionDescription Standard Material FinishActuator Body Extruded Aluminum Alloy AnodizedEnd Cap Die Cast Aluminum Alloy Powder CoatedDrive Shaft (210-260) Stainless Steel PlainDrive Shaft (270-88) Steel Zinc PlatedPiston Die Cast Aluminum Alloy ----Seals Nitrile ----Guide Acetal Resin (POM) PlainO-Rings Nitrile ----Springs Spring Steel Corrosion ProtectedFasteners Stainless Steel Plain External adjustable limit stops 3 , with RCIO offering external adjustable limit stops +/- 3 in both directions.

6 Compact design of end plates, for minimized air consumption Optional Compact Manual Override (Not available on the RCIO88) NAMUR solenoid interface Anodized cylinders, epoxy coated end caps fastened with stainless steel hardware for corrosion resistance Epoxy coating RCT: Hard anodize / low friction polymer treatment Actuator Weights (Lbs.) in 11 inInside the RCI200 ActuatorItemDescriptionDA QTYSR QTYItemDescriptionDA QtySR QTY1 Adjusting Screw1-22 Spring Guide-12 Lock Nut1-23 External Spring-13*O-Ring1-24 Internal Spring-14 Screw8-168-1625 Spring Housing-15 End Plate1-26 Pre-Tensioning Screw-16*O-Ring2227 Indicator117 Cylinder1128*O-Ring-18 scotch Yoke1129 Lock Nut-19*Support Element1130 Marking Washer-110 Piston1131*Upper Retaining Ring1111 Double Rollpin1132*Middle Washer1112*O-Ring1133*Upper Support Washer1114*Support Band1134 Sealing1115 Driving Shaft1135 Lower Support Ring1116 Upper Bearing1136 Lower

7 Bearing1117 End Plate1137 Guide RIng1118*Upper O-Ring1138*Lower O-Ring1119 Upper Supporting Ring1139*Lower Support Washer1120 Piston Pin1140*Lower Retainer Ring1121 Piston Roller11 *Indicates Seal Kit in 11 inRCI200 DimensionsRCI210 to 260 RCI270 to 280 RCI210 to 240 NAMURRCI250 to in 11 inRCI200 Dimensional ChartDimension (Inches)ItemABA1B1 CDEFGHJKMNRCI210 (Inches)ItemUVWXYZHC1HC2HC3HC4 ISO 5211 5211 Fastener Override Rim Pull Forces (Lbs) in 11 inRCI088 Dimensions*No M1 override option available.(Call sales for override options) in 11 inAir Consumption - Displacement StrokeDA Air Consumption (Free Air)ModelAnti-Clockwise RotationClockwise ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon)RCIO260 ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon)DA Operation Time at 80 psi (sec)ModelAnti-Clockwise RotationClockwise Air Consumption (Free Air)ModelBoth ( Gallon) ( Gallon) ( Gallon) ( Gallon) ( Gallon)RCIO260 ( Gallon) ( Gallon)

8 ( Gallon) ( Gallon)SR Operation Time at 80 psi (sec)ModelBoth times are related to full air flow and may increase depending on solenoid valvesand the dimensions of connecting in 11 inTorque Data - Double ActingTorque Output - Double Acting (DA) (DA)0 = Closed90 = Open40 PSI60 PSI80 PSI87 PSI100 PSIRCI2100150220300336370507010514016817 590105170220239265 RCI2200310470620673780501402202903363549 0220335450478565 RCI2300575865115012831430502754055506376 90904256358509291060 RCI2400117017502340256729205056084011201 2831415908651310174018592170 RCIO250018152725363039834510508601285172 0199121709013251990265028323320 RCIO260037155575743080549290501770265535 40407144259027454115549057536860 RCIO270075201128015040167281880550363054 407260832090709055758360111501203713940

9 RCIO280015490232303097033633387205073001 0975146001681618230901150017260230102425 128760 RCIO88030875464606195067266N/A5014600219 0029200336339023010345454602048502 in 11 inTorque Data - Spring Return (SR) (SR)Function0 = Closed90 = Open40 PSI60 PSI80 PSI87 PSI100 PSIRCI210 Air0N/A133175177220604462808090628897110 Spring90N/A97135159170404462808007195106 125 RCI220 Air0168265350363440607110614015917590881 33175195220 Spring9012419526532733540629713015917009 7150200221265 RCI230 Air0318495665690830601241862552923109015 0239320363400 Spring9024838051561163540115186250292309 0177274370416460 RCI240 Air0637982133013981665602573895306026659 0319495665743840 Spring9051378810601239133040239363495602 6200363558750850930 Torque Data - Spring in 11 inTorque Data - Spring Return (SR) (SR)

10 Function0 = Closed90 = Open40 PSI60 PSI80 PSI87 PSI100 PSIRCI0250 Air0106216372210216827456038059379592997 590487752102011511240 Spring9076111951590190319904036355875092 99300549850115013281415 RCIO260 Air0212432744420442555306080512391680190 321259010181593212023452655 Spring9015492389327038944070407611195159 019031990011501770239026993010 RCIO270 Air0424866498850911611154601681256634503 89442909020353097425048685310 Spring9031864956672080548410401549235431 9038943980023013628487054876105 RCIO280 Air0849613098177001841022125603363522170 30796688590424865498850982411060 Spring9065491017813720162851717040318649 56664079668320047797434100001115212480 RCIO88 Air016922261963540036819N/A6068151044314 16015931908496130491770019649 Spring9013186203552743032571406372982313 2701593109558147801991022304 Torque Data - Spring in 11 inFor Customers in 11 inA full listing of our worldwide sales and service network is available on our Control 77 Circuit DriveNorth Kingstown, RI 02582 Tel: +1 401 294 1400 Fax: +1 401 294 3388 Publication Issue 10/12