Example: barber

READ SAFETY DIRECTIONS BEFORE USE

KORDON TERMITE BARRIER Page 1 of 6 APVMA No. 60759-100619 Approved 16 January 2015 MAIN PANEL OF LABEL ATTACHED TO OR PRINTED ONTO PLASTIC WRAP SURROUNDING ROLL / CARTON BOX CONTAINING COLLARS read SAFETY DIRECTIONS BEFORE USE KORDON TERMITE BARRIER ACTIVE CONSTITUENT: 4 g/kg DELTAMETHRIN (Equivalent to 2 g/m2 DELTAMETHRIN) * For label of rolls only For the protection of buildings and structures against subterranean termites in accordance with AS3660 - Termite Management. When used with concrete slab-on-ground also complies with requirements for water vapour barrier as required by AS 2870-1996.

READ SAFETY DIRECTIONS BEFORE USE ... SAFETY DIRECTIONS DO NOT touch or rub eyes, nose or mouth with hand. Facial skin contact may cause temporary facial numbness. Wash hands after use. FIRST AID If poisoning occurs contact a doctor or Poisons Information Centre (Phone Australia 131126, New Zealand 0800 764 766). ...

Tags:

  Safety, Directions, Before, Read, Safety directions, Read safety directions before

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of READ SAFETY DIRECTIONS BEFORE USE

1 KORDON TERMITE BARRIER Page 1 of 6 APVMA No. 60759-100619 Approved 16 January 2015 MAIN PANEL OF LABEL ATTACHED TO OR PRINTED ONTO PLASTIC WRAP SURROUNDING ROLL / CARTON BOX CONTAINING COLLARS read SAFETY DIRECTIONS BEFORE USE KORDON TERMITE BARRIER ACTIVE CONSTITUENT: 4 g/kg DELTAMETHRIN (Equivalent to 2 g/m2 DELTAMETHRIN) * For label of rolls only For the protection of buildings and structures against subterranean termites in accordance with AS3660 - Termite Management. When used with concrete slab-on-ground also complies with requirements for water vapour barrier as required by AS 2870-1996.

2 Full under-slab termite barrier and moisture vapour barrier. For label of collars only A pre-fabricated collar for use on pipe intrusions in concrete slabs. Made from termite resistant sheet material and hence suitable for use as a barrier to deter concealed entry into a building by subterranean termites. Service penetration barrier system. *Approved pack sizes: Single rolls: m2 120 m2 area (width 100 mm to 2400 mm; length 25m or 50m) Number of rolls: 1 30 Collars: Internal diameter: 60 mm, minimum Height 60 mm, minimum Skirt width: 40 mm, minimum Total baseplate width: 140 mm, minimum KORDON TERMITE BARRIER Page 2 of 6 APVMA No.

3 60759-100619 Approved 16 January 2015 ANCILLARY PANEL OF STICKER ON ROLL / PRINTED ON PLASTIC BAG / CARTON BOX CONTAINING COLLARS / FRONT PAGE OF BOOKLET For roll and collar labels: STORAGE AND DISPOSAL Keep out of reach of children. Store in the original packaging in a cool well-ventillated area. DO NOT store for prolonged periods in direct sunlight. Empty packaging and unused product should not be burnt. DO NOT re-use this bag for any other purpose. When using Kordon Termite Barrier there will often be off-cuts or remnants which are produced during use.

4 These remnants and off-cuts should be collected from the site and disposed of as follows: Prior to a concrete pour, place the remnants and cut-offs on top of the moisture barrier, they will be buried under the concrete. Place in a Kordon plastic delivery bag, tie off the end of the bag, and dispose of at an approved waste disposal facility. SAFETY DIRECTIONS DO NOT touch or rub eyes, nose or mouth with hand. Facial skin contact may cause temporary facial numbness. Wash hands after use. FIRST AID If poisoning occurs contact a doctor or Poisons Information Centre (Phone Australia 131126, New Zealand 0800 764 766).

5 SAFETY DATA SHEET Additional information is listed in the SAFETY Data Sheet which is available at Exclusion of Liability This product must be used strictly as directed, and in accordance with all instructions appearing on the label and in other reference material. So far as it is lawfully able to do so, Bayer CropScience Pty Ltd accepts no liability or responsibility for loss or damage arising from failure to follow such DIRECTIONS and instructions. APVMA Approval Number: 60759 / 100619. KORDON is a Registered Trademark of the Bayer Group. Bayer CropScience Pty Ltd 87 000 226 022 Level 1, 8 Redfern Rd, Hawthorn East, Vic.

6 3123 Phone: 03 9248 6888 Technical enquiries: 1800 634 913 Website: Batch Number: DOM: For 24 hour specialist advice in an emergency only phone 1800 033 111 KORDON TERMITE BARRIER Page 3 of 6 APVMA No. 60759-100619 Approved 16 January 2015 ANCILLARY PANEL OF STICKER ON ROLL / PRINTED ON PLASTIC BAG / CARTON BOX CONTAINING COLLARS / BOOKLET INSIDE DIRECTIONS FOR USE: (All States except Tasmania) SITUATION PEST CRITICAL COMMENTS (GENERAL) For roll labels only: New building work, extensions, renovations, retaining walls and other construction situations which require termite protection or management For collar labels only: New building work, extensions, and renovations.

7 Any situation which requires termite protection at the point of the pipe intrusion of the concrete slab. Subterranean termites Users of this product should be familiar with the current edition of the Australian Standard (Termite Management Part 1. New Building Work) and the Building Code of Australia. This product fulfils the performance criteria of a chemical in a non-soil matrix however it s installation should be consistent with the principles of sheet material barriers. The essential design criteria of Kordon Termite Barrier must be fulfilled in order to achieve intended results: Kordon must be installed with the lower (black) membrane facing the direction of expected termite attack.

8 (In some instances this may require folding Kordon back on itself). Kordon Termite Barrier is designed to be compressed between two building elements. The specifics of any installation may vary depending on the situation but in all situations the Accredited Installer needs to ensure that these essential design criteria principles are adhered to. A durable notice must be fixed to the building in accordance with the requirements of the Building Code of Australia. Kordon Termite Barrier will deter concealed entry of termites however regular inspections of the building are recommended as outlined in AS.

9 3660. Termite Management Series and 1995 Inspection of Buildings; to ensure that the entry of termites has not occurred via bridging of the barrier or other means. INSTALLATION TYPE CRITICAL COMMENTS (specific to installation type) Full under-slab system (Termite and Vapour Barrier membrane) For roll labels only: Kordon Termite Barrier should be installed on top of the bedding sand after the footings and plumbing have been completed and BEFORE steel reinforcing is laid for the concrete slab. All slab penetrations are to be protected as part of this treatment (refer Service penetrations below).

10 Where rolls are required to be joined Kordon sheets should taped with duct tape (not less than 30 mm wide) and overlaps should not be less than 200 mm. For collar labels only: The Kordon collars should be pushed down the pipe instrusion with the baseplate at the bottom in contact with the Kordon sheet. Two zip ties should be fastened around the collar. One immediately above the baseplate the other approximately 50 mm higher. The collar should be taped to the Kordon sheet with duct tape (not less than 30 mm wide) and overlaps should not be less than 200 mm.


Related search queries