Example: dental hygienist

Reed sensor For bypass level indicators ... - ksr …

A division of the WIKA groupReed sensor , model BLR-SApplications sensor for the continuous level measurement of liquids in bypass level indicators Chemical, petrochemical industry, natural gas, offshore, shipbuilding, machine building, power generating equipment, power plants Process water and drinking water treatment, food and beverage industry, pharmaceutical industrySpecial features Installation of head-mounted transmitters in the connection housing possible Wide variety of different electrical connections, process connections, materials and contact separations Programmable and configurable head-mounted transmitters for 4 .. 20 mA, HART , PROFIBUS PA or FOUNDATION Fieldbus field signals Explosion-protected versions Temperature ranges from -100.

A division of the WIKA group Reed sensor, model BLR-S Applications Sensor for the continuous level measurement of liquids in bypass level indicators Chemical, petrochemical industry, natural gas, offshore,

Tags:

  Measurement, Levels, Level measurement

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Reed sensor For bypass level indicators ... - ksr …

1 A division of the WIKA groupReed sensor , model BLR-SApplications sensor for the continuous level measurement of liquids in bypass level indicators Chemical, petrochemical industry, natural gas, offshore, shipbuilding, machine building, power generating equipment, power plants Process water and drinking water treatment, food and beverage industry, pharmaceutical industrySpecial features Installation of head-mounted transmitters in the connection housing possible Wide variety of different electrical connections, process connections, materials and contact separations Programmable and configurable head-mounted transmitters for 4 .. 20 mA, HART , PROFIBUS PA or FOUNDATION Fieldbus field signals Explosion-protected versions Temperature ranges from -100.

2 +350 CDescriptionThe model BLR reed sensors are used for continuous monitoring and recording of the liquid level in connection with transmitters. They work on the float principle with magnetic transmission (permanent magnet, reed switch and resistance measuring chain) in a 3-wire potentiometer magnetic system built into the float actuates reed contacts, through the walls of the bypass chamber and of the sensor tube, in a resistance measuring chain (potentiometer). The measurement voltage generated by this is proportional to the fill measurementKSR data sheet LM 1 of 7 KSR data sheet LM 07/2017 Reed sensorFor bypass level indicatorsModel BLRfor further approvals see page 3 The resistance measuring chain is made up from reed contacts and resistors soldered onto a PCB.

3 Depending on requirements and design several different contact separations from 5 to 18 mm are selecting the optimum sensor ( sensor model, connection housing, electrical connection, sensor tube (material and total length), contact separation, head-mounted transmitter, measuring range, approval) we offer application-related technical circuit diagram of the reed sensorsbrownblackblue/greyLegendResistan ceReed contactPage 2 of 7 KSR data sheet LM 07/2017 ApprovalsLogoDescriptionCountryEU declaration of conformity EMC directiveEN 61326 emission (group 1, class B) and interference immunity (industrial application) RoHS directive ATEX directive (option)Hazardous areas- Ex iII 2G Ex ia IIC T4 .. T6 Gb orII 2G Ex ib IIC T4.

4 T6 Gb orII 2D Ex ib IIIC T80 C DbNo. KEMA 01 ATEX 1052 X- Ex dII 2G Ex d IIC T6 Gb orII 2D Ex tb IIIC T80 C DbNo. T V 13 ATEX 7399 XEuropean UnionIECEx (option)Hazardous areas- Ex dZone 1/2-40 C Ta +55 CEx d IIC T6 Ex tD A21 IP65 T80 CNo. IECEx TUR EMC directiveNo. TC N RU Д Hazardous areasNo. RU C-DE.ГБ Economic CommunityGOSTM etrology, measurement technologyNo. 19359 RussiaKazInMetrMetrology, measurement technologyNo. 13947 KazakhstanBelGIMM etrology, measurement technologyNo. 9711 BelarusUkrSEPROM etrology, measurement technologyNo. UA-MI/2-4988-2015 UkraineUzstandardMetrology, measurement technologyNo. areasNo. P331149/1 IndiaDNV GLShips, shipbuildingNo. TAA00000M2 InternationalApprovals and certificates, see websitePage 3 of 7 KSR data sheet LM 07/2017 Reed sensor , standard version with connection housingModels BLR-SA, BLR-SBGuide tube and float made of stainless steelModel BLR-SAModel BLR-SBElectrical connectionConnection housing: Aluminium 80 x 75 x 57 mmOption: Polypropylene, polyester, stainless steelConnection housing: Aluminium 80 x 75 x 57 mm with head-mounted transmitterOption: Polypropylene, polyester, stainless steelGuide tube diameter14 mmTemperature range Standard version High-temperature version Low-temperature version Standard version with Mikroterm High-temperature version with Mikroterm-50.

5 +100 C-50 .. +200 C-100 .. +100 C-50 .. +250 C-50 .. +350 mm / mm / mm / 9 mm(depending on contact separation)Overall resistance of the measuring chainDepending on length and separationHead-mounted transmitterExternal transmitterHead-mounted transmitter, see page 7 Output3-wire potentiometer4 .. 20 mAPermissible power supply< AC 50 V, < DC 75 VSee the data sheet of the head-mounted transmitter usedIngress protectionup to IP66 or IP68 per IEC/EN 60529 (depending on version)~ 14M= ..50100 %0 %Aluminium and polyester connection housing125 7077113 Stainless steel connection housing8077 70 Stainless steel connection housing with digital indicator (option)Page 4 of 7 KSR data sheet LM 07/2017 Model BLR-SAI ( )Model BLR-SBI ( )Electrical connectionConnection housing: Aluminium 80 x 75 x 57 mmOption: Stainless steelConnection housing: Aluminium 80 x 75 x 57 mm with head-mounted transmitterOption: Stainless steelGuide tube diameter14 mmMaximum permissible surface temperature at the sensor tubeT4: +100 CT5: +65 CT6: +50 mm / mm / mm / 9 mm(depending on contact separation)Overall resistance of the measuring.

6 50 k Control circuitIgnition protection type Ex ia IIC (only for connection to a certified intrinsically safe control circuit) and ignition protection type intrinsically safe Ex ib IICHead-mounted transmitterExternal transmitterHead-mounted transmitter, see page 7 Output3-wire potentiometer4 .. 20 mAPermissible power supply< AC 50 V, < DC 75 VSee the data sheet of the head-mounted transmitter usedIngress protectionup to IP66 or IP68 per IEC/EN 60529 (depending on version)Reed sensor , explosion-protected version Ex i, intrinsically safeModels BLR-SAI, BLR-SBI ( )KEMA 01 ATEX 1052 X (II 2G Ex ia IIC T4 .. T6 Gb, II 2D Ex ib IIC T4 .. T6 Gb or II 2 D Ex ib IIIC T80 C Db)Guide tube and float made of stainless steel~ 14M=.

7 50100 %0 %Aluminium and polyester connection housing125 7077113 Stainless steel connection housing8077 70 Stainless steel connection housing with digital indicator (option)Page 5 of 7 KSR data sheet LM 07/2017 Reed sensor , explosion-protected version Ex d, flameproof enclosureModels BLR-SAD, BLR-SBD (AVK-ADF)T V 13 ATEX 7399 X (II 2G Ex d IIC T6 Gb / II 2 D Ex tb IIIC T80 C Db)IECEx TUR (-40 C Ta +55 C Ex d IIC T6 Ex tD A21 IP65 T80 C)Guide tube and float made of stainless steelModel BLR-SAD (AVK-ADF)Model BLR-SBD (AVK-ADF)Electrical connectionConnection housing:Aluminium 170 x 151 x 87 mmOption: Stainless steelConnection housing: Aluminium 170 x 151 x 87 mm with head-mounted transmitterGuide tube diameter14 mmMaximum permissible surface temperature at the sensor tubeT4: +100 CT5: +65 CT6: +50 mm / mm / mm / 9 mm(depending on contact separation)Overall resistance of the measuring chainDepending on length and separationHead-mounted transmitterExternal transmitterHead-mounted transmitter, see page 7 Output3-wire potentiometer4.

8 20 mAPermissible power supply< AC 50 V, < DC 75 VSee the data sheet of the head-mounted transmitter usedIngress protectionup to IP66 or IP68 per IEC/EN 60529 (depending on version)1707511087L= .. 14 Page 6 of 7 KSR data sheet LM 07/2017 KSR KUEBLER Niveau-Messtechnik AGHeinrich-Kuebler-Platz 169439 Zwingenberg/GermanyTel. +49 6263/87-0 Fax +49 A division of the WIKA groupOrdering informationModel / Connection housing / Electrical connection / sensor tube (material and total length) / Contact separation, head-mounted transmitter / Measuring range / Approval / OptionsTo order the described product the order number (if available) is transmitterModel4 .. 20 mAHART PROFIBUS PAFOUNDATION FieldbusEx iDisplayOrder T15 Model T32 Model T53 Model TLEH 08/2014 KSR KUEBLER Niveau-Messtechnik AG, all rights specifications given in this document represent the state of engineering at the time of reserve the right to make modifications to the specifications and ENPage 7 of 7 KSR data sheet LM 07/2017