1 R El A Y S A N D C O N T A C T O R SType 586 s PDTD . C . P o w e r C o n t a c t o r s Ty p e E n g i n e e r i n g D e s i g n D a t a operation in % of n om. Breakdown Voltages coil Rating coil Voltage Rating All Terminals - 60 h z Rms contact material electrical l ife mechanical l ife nominal open max. magnetic max. contacts oper. oper. oper. coil Rating safe opposite same To oper. At Per oper. At Per Temp. Type (Watts) Pick-up operate Polarity Polarity Ground Power Pilot Rated l oad min. no l oad min F 586 8 - SPNO 75% 110% 500 500 500 Silver Alloy - 50,000 2 100,000 30 150 12 - SPDT For outline drawings refer to page Range -40 F to 150 FTerminations Contacts: 5/16"-24 UNF-2A thread Coil: #10-32 UNF-2A threadRecommended mounting Vertical plane with coil terminals Torque s pecification Contact Terminal: 60 inch-lbs.
2 , max. Coil Terminal: 12-18 inch lbs. Water Resistant* Terminal Type: 4 = Isolated Coil 6 = Isolated Coil** Inrush Current: Current applied within the first 1/2 second of contact closure coil contact Rating-(Amps.) DImensIons Stancor coil Resistance Inductive l oad Inches PART Duty Terminal Pole Bracket Volt. (ohms) contact Volt. normally o pen normally c losed case Weight Agency sec. nUmBeR cycle Type* Form style @25 c material continuous Inrush** continuous Inrush** l W h (oz.) certif. A 586-901 Continuous 4 SPNO Standard 6 Silver Alloy 6 200 600 - - - 586-902 Continuous 4 SPNO Standard 12 Silver Alloy 12 200 600 - - - 586-903 Continuous 4 SPNO Standard 15 Silver Alloy 15 200 600 - - - B 586-905 Continuous 4 SPNO Standard 24 Silver Alloy 24 200 600 - - - 586-906 Continuous 4 SPNO Standard 36 Silver Alloy 36 200 600 - - - 586-907 Continuous 4 SPNO Standard 48 Silver Alloy 36 200 600.
3 - C 586-911 Continuous 6 SPDT Standard 12 Silver Alloy 12 200 600 100 300 - 586-914 Continuous 6 SPDT Standard 24 Silver Alloy 24 200 600 100 200 - 586-915 Continuous 6 SPDT Standard 36 Silver Alloy 36 200 600 100 200 -Type 586 c ustom Design c apabilities Coil voltages 6 VDC through 48 VDC High vibration Please complete application data form on page 95 of this section. note: caution must be used in coil selection for use in 12 volt systems where battery charging may expose coil to continuous, higher-than-rated voltage.
4 S tancor will not be responsible for consequences of misapplied 586 s R El A Y S A N D C O N T A C T O R wIde X .600 lonG slot5/16-24 unf-2A X .594 lonG#10-32 unf-2A X .375 wIde X .600 lonG slot5/16-24 unf-2A X .594 lonG#10-32 unf-2A X .375 lonGTerminal Type Isolated Coil SPNOT erminal Type Isolated Coil SPDTTy p e