Transcription of Reliability Analysis Data Manual - NYISO
1 Manual 24 Reliability Analysis data Manual December 2016 Version: Effective Date: 12/01/2016 Committee Acceptance: 06/16/2016 This document was prepared by: System and Resource Planning New York Independent System Operator 10 Krey Boulevard Rensselaer, NY 12144 (518) 356-6060 Disclaimer The information contained within this Manual , along with the other NYISO manuals, is intended to be used for informational purposes and is subject to change. The NYISO is not responsible for the user s reliance on these publications or for any erroneous or misleading material.
2 Copyright 1999-2016 New York Independent System Operator NYISO Reliability Analysis data Manual iii System and Resource Planning Version 12/01/2016 Table of Contents Table of Figures .. iv Table of Tables .. iv Revision History .. v 1. Overview .. 1-1 Purpose and Scope .. 1-1 NYISO data Classification .. 1-2 Treatment of data .. 1-3 Critical Energy Infrastructure Information (CEII) .. 1-3 Confidential data .. 1-4 data Requests .. 1-4 Reliability Analysis Databases .. 1-4 NYISO Database .. 1-4 FERC Form 715: Annual Transmission Planning and Evaluation Report.
3 1-5 ERAG MMWG Steady State Base Cases .. 1-6 NPCC Steady State Base Cases .. 1-6 Bulk Power Transmission 1-6 2. NYISO Database Update Procedures .. 2-1 Annual Database Update Process .. 2-1 Facility Owner Updates .. 2-6 data Notification Requirements .. 2-7 New York Transmission Owner data Coordinator Requirements .. 2-7 NYCA Facility Owner 2-7 Generation Capability Reporting .. 2-8 Real Power Capability .. 2-8 Real Power Capability Demonstration Exemptions .. 2-9 Reactive Power Capability .. 2-9 Reactive Power Capability Demonstration Exemptions.
4 2-10 NYISO data Screening Procedure .. 2-11 NYISO Model Validation Procedure .. 2-11 NERC MOD-025-2 .. 2-11 NERC MOD-026-1 and NERC MOD-027-1 .. 2-11 NERC MOD-033-1 .. 2-12 3. System Network Representation .. 3-1 Network Model data .. 3-1 Facility Ratings .. 3-1 Load data .. 3-2 Dynamics Model data .. 3-3 Generator Dynamics data .. 3-3 Generator Controls Dynamics data .. 3-4 Network Dynamics data .. 3-4 Load Dynamics Model data .. 3-4 Contingency data .. 3-4 Steady State Contingency Modeling data .. 3-4 Dynamic Contingency Modeling 3-5 Short Circuit data .
5 3-5 4. Real-Time System Representation .. 4-1 Real-Time System Representation data .. 4-1 NYISO Reliability Analysis data Manual System and Resource Planning iv Version 12/01/2016 System Network Representation 4-1 Facilities Ratings data .. 4-2 Dynamic Rating Updates .. 4-2 Operating System Representation .. 4-2 Operating System Representation Definitions .. 4-3 System Representation Review Procedure .. 4-3 Review of Real-time Contingencies and Monitored Lines .. 4-3 Attachment A. NYISO Steady State Database Forms.
6 A-1 Attachment B. Real Power Capability Reporting Form .. B-1 Attachment C. Reactive Power Capability Reporting Form .. C-1 Attachment D. NYISO data Screening Procedure .. D-1 Attachment E. NYISO Dynamic Rating Facilities .. E-1 Attachment F. NYISO EMS Common Information Model data Base .. F-1 Table of Figures Figure 2-1: Illustrative timeline for the NYISO Database update process ..2-5 Figure 3-1: Zero Impedance Line from Bus A to Bus C ..3-6 Table of Tables Table 2-1: Real Power Level Requirements for Reactive Power Capability Testing.
7 2-10 Table E-1: Table of Facilities That Can Be Updated Dynamically (Listing by Rating Authority) .. E-1 Table F-1: Substation F-2 Table F-2: Busbar data .. F-3 Table F-3: Synchronous Machine data .. F-4 Table F-4: Conductor data .. F-5 Table F-5: Transformer data .. F-6 Table F-6: Energy Consumer data .. F-7 Table F-7: Compensator data .. F-8 Table F-8: Switch data .. F-9 Table F-9: Static Var Compensator data .. F-10 Table F-10: Facility Ratings Update data .. F-11 NYISO Reliability Analysis data Manual v System and Resource Planning Version 12/01/2016 Revision History Version Date Revisions 12/01/2016 Attachment Only Revision Attachment E Updated list of dynamic ratings 07/01/2016 Global Changed case references to be consistent with MOD-032-1 (steady state, dynamic, and short circuit)
8 Implemented minor stylistic changes Updated references to NYSRC Reliability Rules Section Added additional NERC and NPCC Reliability criteria and removed references to retired Reliability criteria Section Updated list of cases and contingency definitions maintained in the NYISO database Section Added new section on Bulk Power Transmission Facilities Section Updated the annual database update process Section Updated section to reflect changes to communications for power system model changes Section Added new section to address new NERC MOD standards and Technical Bulletin 233 Section Updated section to require Generator Owners to provide station service auxiliary load data Section Added new section to address contingency reporting requirements Section Added Lowest Circuit Breaker ratings to short circuit data reporting requirements Attachment A Updated list of generating plant unit types Removed requirement for the reporting of three-winding transformers as a grouping of three two-winding
9 Transformers 11/22/2013 Section Changed Directory#9 Section reference to Directory#9 Section reference. Section Added an additional exemption criterion to be consistent with NYISO Reliability Analysis data Manual System and Resource Planning vi Version 12/01/2016 Directory#9 Section Section Added additional exemption criteria to be consistent with Directory#10 Section 11/07/2011 Global Changed the title of the Manual from System Analysis data Manual to Reliability Analysis data Manual Reformatted per new template to standardize presentation.
10 Implemented minor stylistic changes. Standardized labeling and numbering of graphical and tabular material. Implemented programmatic linking for internal cross-references to facilitate navigation within the document. Added external-document links that explicitly cite URLs from which documents may be accessed and that reflect changes in location secondary to NYISO Web site redesign. Performed a major rewrite and reorganization of content. Technical Bulletins merged: o 160, Market Participant Notification of NYISO Network Power System Model Updates (Created new Section ) o 190, Reactive Power Testing for Non-VSS Generators (Created new Section ) o 191, Non-ICAP NYCA Generators Must Report Capacity data as Required by NPCC Directory #9 (Created new Section ) Front Matter Reformatted Revision History as tabular material.