Example: tourism industry

REMANUFACTURED ENGINE - PowerForce

Series: PF 12V71 TSeries: PF 12V71 TRating Data of 2-Cycle Detroit Diesels:Specification & Application DataPowerForce Corporate Office 9200 Liberty Drive Liberty MO 64068 Ph Fax Gross BHP 85 F ( C)60 F ( C)RPMR ated Gross BHP (kW)525 (392) BHP(kW) Torque lb ft (NM)1450 (1966)1600 Rated Gross HP - ENGINE gross BHP ratings are given for inlet temperatures of 85 F ( C) and 60 F ( C). All ratings and RPMs, including continuous BHP ratings, are as detailed on the chart to the left. Photo depicts an ENGINE model from this series but may not include certain optionsEngine SpecificationsOriginal Manufacturer & ModelDetroit Diesel 12V71 TRemanufacturerPOWERFORCE Number of cylinders 12 ArrangementVAspirationTurbo-chargedDispl acement CID. (Liters)852 cu. ins. ( L)Bore x Stroke inches (mm) X (108mm X 127mm)InjectorsN75 Compression : 1 Combustion Cycle2-Cycle Detroit DieselHistory of ENGINE SeriesIntroduction1938In-line engines now available3, 4 and 6 cylinderV engines now available6, 8, 12, and 16 cylinderTypical applications for EngineOn HighwayMilitaryConstructionPower GenerationOil & GasIndustrialMarineDimensions - inches (mm)LengthWidthHeightWeight lbs (kg)70 (1778)46 (1168)

REMANUFACTURED 2-CYCLE DETROIT DIESEL ENGINES Series: PF 12V71T POWERFORCE ® Remanufactured 2 - Cycle Detroit Diesels Engines comply with applicable codes and standards ...

Tags:

  Remanufactured, Engine, Remanufactured engine

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of REMANUFACTURED ENGINE - PowerForce

1 Series: PF 12V71 TSeries: PF 12V71 TRating Data of 2-Cycle Detroit Diesels:Specification & Application DataPowerForce Corporate Office 9200 Liberty Drive Liberty MO 64068 Ph Fax Gross BHP 85 F ( C)60 F ( C)RPMR ated Gross BHP (kW)525 (392) BHP(kW) Torque lb ft (NM)1450 (1966)1600 Rated Gross HP - ENGINE gross BHP ratings are given for inlet temperatures of 85 F ( C) and 60 F ( C). All ratings and RPMs, including continuous BHP ratings, are as detailed on the chart to the left. Photo depicts an ENGINE model from this series but may not include certain optionsEngine SpecificationsOriginal Manufacturer & ModelDetroit Diesel 12V71 TRemanufacturerPOWERFORCE Number of cylinders 12 ArrangementVAspirationTurbo-chargedDispl acement CID. (Liters)852 cu. ins. ( L)Bore x Stroke inches (mm) X (108mm X 127mm)InjectorsN75 Compression.

2 1 Combustion Cycle2-Cycle Detroit DieselHistory of ENGINE SeriesIntroduction1938In-line engines now available3, 4 and 6 cylinderV engines now available6, 8, 12, and 16 cylinderTypical applications for EngineOn HighwayMilitaryConstructionPower GenerationOil & GasIndustrialMarineDimensions - inches (mm)LengthWidthHeightWeight lbs (kg)70 (1778)46 (1168)55 (1397)3550lbs (1610)Information Required On OrderingEngine Serial #Required to Determine Model Number and spec buildDetroit ENGINE ModelOriginal ENGINE ConfigurationHas ENGINE been changed outTo ensure correct ENGINE buildApplicationThe equipment it s in or what it powersStandard AccessoriesPulleysWhere ApplicableLifting EyesLifting Eye Located on HeadOil FilterSupplied on ENGINE where applicableOptional equipment availableElectric Start12 volt Starter MotorEngine Mounted Battery ChargingAlternator and alternator drivesFuel FiltrationComplete Fuel Filter SystemAir CleanerReplaceable Element or AssemblyProtectionEngine Shut Down SystemsDriveFlywheel and/or Flex PlatesCooling AccessoriesFan Hub and Fan Drive AssembliesAir CompressorCompressor and Compressor DrivePaintCustom Paint AvailableCustomer ENGINE CoreCan Reman

3 Core with AccessoriesEngine HeatersWhen ApplicableREMANUFACTURED ENGINE DETROIT DIESEL 2-CYCLEPOWERFORCE - A Premium Brand For Power and DriveRemanufactured Detroit Diesel 2-Cycle Enginesfor On & Off Highway Applications: PowerForce Detroit Diesel 2-Cycle Engines are completely REMANUFACTURED to ensure quality and performance. All parts used are genuine, or to original OEM ENGINE is REMANUFACTURED in a purpose built facility, with remanufacturing resources supported by more than 60-years of experience and knowledge in remanufacturing Detroit Diesel 2-Cycle engines. PowerForce is one, of only a few, sources for fully REMANUFACTURED Detroit Diesel 2-Cycle Power Systems & Services is renowned for in-house training on 2-cycle technology. The PowerForce team has a multi-step program to ensure engines are REMANUFACTURED to original OEM specification.

4 All engines are dynamometer PowerForce team has extensive Detroit Diesel 2-Cycle application experience to assist has a fair no hassle exchange program for ENGINE 2-CYCLE DETROIT DIESEL ENGINESS eries: PF 12V71 TPOWERFORCE REMANUFACTURED 2 - Cycle Detroit Diesels Engines comply with applicable codes and standardsPowerForce Corporate Office 9200 Liberty Drive Liberty MO 64068 Ph Fax # DS- data subject to change without notice. The information in this white-page specification is believed to be accurate but all recommendations are made without warranty, since the conditions of use are beyond Central Power Systems & Services control. Central Power Systems & Services disclaims any liability in connection with the use of this information, and does not warrant against infringement by reason of the use of any of its products in combination with other material or in any process.

5 Central Power Systems & Services warrants only that the product complies with specifications agreed to in contracts of sale. Central Power Systems & Services reserves the right to change any of the technical information and data detailed in this accurately provide PowerForce Engines and to avoid any potential charge-backs on cores or for returned product, it is imperative that all information supplied is correct and that the ENGINE in the equipment is like for like. If the ENGINE has ever been changed out, it should be reviewed for potential SPEED - RPM1450 LB FTTORQUETORQUE - LB FTBRAKE HORSEPOWERFUEL - LB/BHP HR525 BHP1315 LB FTFUEL ENGINE PERFORMANCEMODEL: PF 12V71T WITH N75 INJECTORSRATED POWER OUTPUTGUARANTEED WITHIN 5% ATSAE STD AMBIENT CONDITIONS:RATED BHPPERFORMANCE AT SAE STANDARDCONDITIONS OF 85 F ( C) AIR TEMPERATURE AND IN.

6 HG ( kPa) BAROMETER (DRY) PowerForce - A Premium Brand For Power and Drive 2013 PowerForce a registered brand of Central Power Systems & Services. All rights are subject to change without notice.