Example: bachelor of science

REMOTE PUMPS - FillRite

Owner's Operation & Safety ManualREMOTE PUMPSM odels FR713, 303, 313 Model 303 and 313 OUTSTANDING FEATURES Up to 18 GPM / 60 LPM UL & C-UL Listed 1/3 HP 115 VAC-60Hz motor,optional 220/240 VAC-50/60Hz Thermal overload protector Integral check valve Built-in bypass valve Anti-siphon deviceOUTSTANDING FEATURES Up to 30 GPM / 114 LPM UL & C-UL Listed 3/4 HP 115/230 VAC-60Hz motor(313). For diesel applications. Notrecommended for gasoline. 1/2 HP 115/230 VAC-60Hz motor(303). For gasoline and dieselapplications. Thermal overload protector Integral check valve Built-in bypass valve Anti-siphon deviceModel FR713 Dear Fill-Rite Customer,Congratulations on your purchase of a Fill-Rite RemotePump. We at Fill-Rite have built our worldwide reputation bydesigning the finest and most reliable PUMPS available intoday s new pump was designed with pride by some of the bestand most experienced fluid control experts available.

Model FR713 ŁFull 1/3 HP, 220/240 VAC, 50/60Hz motor Pumps are furnished with factory installed anti-siphon devices and must be …

Tags:

  Pumps, Remote, Remote pumps

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of REMOTE PUMPS - FillRite

1 Owner's Operation & Safety ManualREMOTE PUMPSM odels FR713, 303, 313 Model 303 and 313 OUTSTANDING FEATURES Up to 18 GPM / 60 LPM UL & C-UL Listed 1/3 HP 115 VAC-60Hz motor,optional 220/240 VAC-50/60Hz Thermal overload protector Integral check valve Built-in bypass valve Anti-siphon deviceOUTSTANDING FEATURES Up to 30 GPM / 114 LPM UL & C-UL Listed 3/4 HP 115/230 VAC-60Hz motor(313). For diesel applications. Notrecommended for gasoline. 1/2 HP 115/230 VAC-60Hz motor(303). For gasoline and dieselapplications. Thermal overload protector Integral check valve Built-in bypass valve Anti-siphon deviceModel FR713 Dear Fill-Rite Customer,Congratulations on your purchase of a Fill-Rite RemotePump. We at Fill-Rite have built our worldwide reputation bydesigning the finest and most reliable PUMPS available intoday s new pump was designed with pride by some of the bestand most experienced fluid control experts available.

2 We usethe most advanced technology possible to give you a pumpwith the superiority you deserve and the quality you ve cometo expect from Fill-Rite P. JenkinsPresidentGENERAL DESCRIPTION2 SAFETYThe Fill-Rite Series 700B UL listed REMOTE PUMPS are positivedisplacement, direct drive, rotary vane PUMPS . Depending oninstallation and product viscosity, these PUMPS can deliver upto 18 gallons of fluid per minute. Their rugged, yet lightweightdesign makes for a long life of trouble free Fill-Rite Series 300 UL listed PUMPS are positivedisplacement, direct drive, rotary vane PUMPS . Depending oninstallation and product viscosity, these PUMPS can deliver upto 30 gallons/114 liters of fluid per minute. Their high quality,trouble free design makes them a reliable, long life, highcapacity safety of Fill-Rite Series 700B and 300 PUMPS is provenby their listing withUnderwriters Laboratories Inc.

3 , a nationallyrecognized independent organization fortesting of products to ensure public safety. Alsorecognized in FR713 Design Features: Inlet: 2" male NPT on bung, 1 " female NPT on suctionpipe Outlet: " NPT Built in check valve, bypass and pressure relief valves.(Anti-siphon device prevents thermal expansion pressurebuildup.)CAUTION: DO NOT INSTALL ADDITIONAL FOOTVALVE OR CHECK VALVE DURING INSTALLATIONWITHOUT PRESSURE RELIEF VALVE. HOUSINGOR PLUMBING CRACKING MAY RESULT. Overall Dimensions: 14" ( ) wide x 11" (28cm) high x12" ( ) deep Explosion proof motor 1/3 HP 115 VAC-60Hz motor, 1725 RPM, amps at 115 VAC Thermal overload protection Ball bearing construction; no greasing or oiling requiredModel FR713 Performance: 22 psi ( bar) maximum outlet pressure Maximum flow rate: up to 18 GPM (68 LPM) Maximum viscosity of fluid pumped: diesel fuel Maximum operating ambient temperature: 150 F ( C) Minimum operating ambient temperature: -15 F (-27 C) (Consult factory for extreme temperature applications) Minimum dry vacuum: 12" ( ) of mercury Minimum suction lift: 10' (3m) for gas & 15' ( ) for dieselfuel.

4 The lift in feet is equivalent to the vertical distance fromthe surface of the fluid in the tank to the inlet of thepump, PLUS the friction losses through the vertical andhorizontal runs of pipe, all elbows and other should be designed to require a minimumamount of suction INFORMATIONTo ensure safe and efficient operation, it is essential toread and follow each of these warnings To prevent damage to FR713 pump, do not operatewithout the check valve (700F2661) or the checkvalve substitute (700F2679) in Do NOT smoke near pump or use pump near an openflame. Fire could Take motors needing service to an authorizedrepair shop or return to factory to maintain explosion proof These PUMPS must be used with remotedispensers and are not intended for any The pump motor is equipped with thermal overloadprotection.

5 If overheated, it will shut itself off withoutany damage to the windings. Be sure to turn off thepump power if this occurs. As the motor cools, it willstart without warning if power is wiring should bedone by a licensed electri-cian in accordance with ap-proved electrical should be properlygrounded and a rigid conduitshould be used when install-ing electrical wiring. Im-proper use or installation ofthis product can cause seri-ous bodily injury or INSTRUCTIONSM odel FR713 Full 1/3 HP, 220/240 VAC, 50/60Hz motorPumps are furnished with factory installed anti-siphon devicesand must be installed in accordance with the applicablerequirements of the Automotive and Marine Service StationCode, NFPA No. 30A, and the National Electrical Code, NFPANo. 70. They are designed for use either inside or outside ofbuildings subject to the acceptance of inspection authoritieshaving jurisdiction at points of installation must include one (or more) UL listedremote dispenser(s) with a UL listed emergency shut-offvalve with fusible link located at dispenser inlet.

6 If a non-ULlisted dispenser is used without a solenoid valve, the systemmust consist of one dispenser only. All piping should beSchedule 40. Use UL classified gasoline and oil resistant pipecompound on all threaded REMOTE Dispenser Owner's Operation & Safety Manual forcomplete installation and operation instructions. The followingdispensers are available from Fill-Rite. Model 317 "Weights & Measures" Elite Models 315S, 315ST with 2% accurate meter Model FR307 AST "Weights & Measures", UL listed Models FR305R, 305R AST with 2% accurate meterPump has a built-in check valve with pressure relief to preventfluid thermal expansion from causing unsafe system NOT USE ADDITIONAL CHECK VALVES OR FOOTVALVES UNLESS THEY HAVE PROPER PRESSURE RELIEFVALVES BUILT INTO InstallationMount pump securely on top of tank in proper position forconnecting piping to dispenser.

7 Tighten pump by using pipewrench ONLY on tank adapter, being careful not to damageanti-siphon return FR713, 303, and the 313 require a 1 " suction 303, 313 Franklin motorsVoltage select screw should be placed next tocorrect voltage setting (115 VAC shown)VOLTAGE SELECTION SWITCHM odels 303 and 313 Design Features: Inlet: 2" male NPT on bung, 1 " female NPT on suction pipe Outlet: 1" NPT Built in check valve, bypass and pressure relief valves.(Anti-siphon device prevents thermal expansion pressurebuildup.)CAUTION: DO NOT INSTALL ADDITIONAL FOOTVALVE OR CHECK VALVE DURING INSTALLATIONWITHOUT PRESSURE RELIEF VALVE. HOUSINGOR PLUMBING CRACKING MAY RESULT. Cast iron pump housing: bronze rotor and carbon vanes Overall Dimensions: 14 " ( ) wide x 14 " ( )high x 7 " ( ) deep Explosion proof motor 313: HP 115/230 VAC-60Hz dual voltage motor, 1725 RPM, 11 amps at 115 VAC or amps at 230 VAC 303: HP 115/230 VAC-60Hz dual voltage motor, 1140 RPM, amps at 115 VAC or amps at 230 VAC Thermal overload protection Ball bearing construction.

8 No greasing or oiling requiredModels 303 & 313 Performance: 25 psi ( bar) maximum outlet pressure 313: up to 30 gpm (114 lpm) 303: up to 20 gpm (76 lpm) Maximum viscosity of fluid pumped: diesel fuel Maximum operating ambient temperature: 150 F ( C) Minimum operating ambient temperature: -15 F (-27 C) (Consult factory for extreme temperature applications) Minimum dry vacuum: 14" ( ) of mercury Minimum suction lift: 10' (3m) for gas & 18' ( ) for dieselfuel. The lift in feet is equivalent to the vertical distancefrom the surface of the fluid in the tank to the inlet of thepump, PLUS the friction losses through the vertical andhorizontal runs of pipe, all elbows and other fittings. Sys-tems should be designed to require a minimum amountof suction CompatibilityThe FR713, 303, and the 313 are compatible with thefollowing fluids: Diesel, Gasoline, Kerosene, Mineral Spirits, Heptane,and HexaneNOTE: Only the 303 and FR713 versions arerecommended for gasoline FR713, 303, and the 313 are NOT compatible with thefollowing fluids.

9 Acetone, Ammonia, Benzene, Bleach, HydrochloricAcid, Ink, and TolueneIf in doubt about compatibility of a specific fluid, contactsupplier of fluid to check for any adverse reactions to thefollowing wetted IronSteelStainless SteelBronze/IronCarbonPolyesterFiberVito nBuna NZinc Plated SteelCeramicAluminumOPTIONSINSTALLATION0 510152025300246 81012141618202224262830324FR713 FLOW CURVE*Flow in GPMD ischarge Presssure (PSI)05101520250246810 12 14 16 18 20 22 AXBXFlow in GPMD ischarge Presssure (PSI)313 FLOW CURVE*A) 303 with 12' of 3/4" hose and manual ) 303 with 12' of 3/4" hose and automatic ) 303 with 12' of 3/4" hose, automatic nozzle, and FR305 Rdispenser.*Nominal flow curve for reference only. Based on 3 feetsuction lift. Actual flow rate may ) FR713 with 12' of 3/4" hose and manual ) FR713 with 12' of 3/4" hose and automatic ) FR713 with 12' of 3/4" hose, automatic nozzle, andFR305R dispenser.

10 *Nominal flow curve for reference only. Based on 3 feetsuction lift. Actual flow rate may BreakersPower to the unit should be supplied from a dedicated circuitbreaker, 20 amp for FR713 and 30 amp for 303 & 313. No otherequipment should be powered from this breaker. If two pumpsare supplied from one breaker, that breaker must be capable ofhandling the load of both motors. Provision must be made tobreak both legs of any AC REMOTE dispenser installation instructions in the Owner'sOperation & Safety Manual for completing the maintain UL listing, motors that need repair should be takento an authorized repair shop or returned to factory for must be thoroughly flushed and drained before beingtaken in for keep pump running at its best, periodically perform thefollowing FR713:1.


Related search queries