Required number of 16d common nails per connection, wood

24"11'-9"24"2x616"14'-1"16"12"15'-6"12"2 4"14'-10"24"2x816"18'-2"16"12"20'-5"12"2 4"18'-2"24"2x1016"22'-3"16"12"25'-8"12"2 4"21'-0"24"2x1216"25'-9"16"12"26'-0"12"S ize20' Building width28' Building width2-2x65'-5" w/ 1 NJ4'-8" w/ 1 NJ2-2x86'-10" w/ 1 NJ5'-11" w/ 2 NJ12202-2x108'-5" w/ 2 NJ7'-3" w/ 2 NJ24"8'-1"2-2x129'-9" w/ 2 NJ8'-5" w/ 2 NJ16"9'-9"3-2x1212'-2" w/ 2 NJ10'-7" w/ 2 NJ165812"10'-9"24"10'-3"16"12'-7"12"14'- 2"24"12'-7"164616"15'-5"12"17'-9"24"14'- 7"2-2x64'-6" w/ 1 NJ3'-11" w/ 1 NJ16"17'-10"2-2x85'-9" w/ 1 NJ5'-0" w/ 2 NJ12"20'-7"2-2x107'-0" w/ 2 NJ6'-1" w/ 2 NJ16352-2x128'-1" w/ 2 NJ7'-0" w/ 2 NJ3-2x1210'-2" w/ 2 NJ8'-10" w/ 2 NJSpan ratingMin.

ALLOWABLE SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF & SUBFLOOR SHEATHING Load (psf) Sheathing Roof 4 19-10" GIRDER AND HEADER SPANS FOR EXTERIOR BEARING WALLS (DF-LARCH #2) [Table R502.5(1)] NJ = Number of jacks studs required to support each end. 8 TIE SPACING 16d (3-1/2" x 0.135") ...

Tags:

  Woods, Allowable

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Required number of 16d common nails per connection, wood

1 24"11'-9"24"2x616"14'-1"16"12"15'-6"12"2 4"14'-10"24"2x816"18'-2"16"12"20'-5"12"2 4"18'-2"24"2x1016"22'-3"16"12"25'-8"12"2 4"21'-0"24"2x1216"25'-9"16"12"26'-0"12"S ize20' Building width28' Building width2-2x65'-5" w/ 1 NJ4'-8" w/ 1 NJ2-2x86'-10" w/ 1 NJ5'-11" w/ 2 NJ12202-2x108'-5" w/ 2 NJ7'-3" w/ 2 NJ24"8'-1"2-2x129'-9" w/ 2 NJ8'-5" w/ 2 NJ16"9'-9"3-2x1212'-2" w/ 2 NJ10'-7" w/ 2 NJ165812"10'-9"24"10'-3"16"12'-7"12"14'- 2"24"12'-7"164616"15'-5"12"17'-9"24"14'- 7"2-2x64'-6" w/ 1 NJ3'-11" w/ 1 NJ16"17'-10"2-2x85'-9" w/ 1 NJ5'-0" w/ 2 NJ12"20'-7"2-2x107'-0" w/ 2 NJ6'-1" w/ 2 NJ16352-2x128'-1" w/ 2 NJ7'-0" w/ 2 NJ3-2x1210'-2" w/ 2 NJ8'-10" w/ 2 NJSpan ratingMin.

2 PanelRoof / floor spanthickness (in.)Edge support (2x blocking)No edge supportTotal loadLive load24/0 3/82420403024/16 7/162424504032/1615/32, 1/23228403040/2019/32, 5/84032403048/2423/32, 3/448364535 Rafter to plate RAFTER TIE CONNECTIONSRoof live load 20 psf [(Table (9)] Required number of 16d common nails per connection, wood members shall be of sufficient size to prevent splitting due to nailing. Split members shall be removed and SPANS AND LOADS FOR WOOD STRUCTURAL PANELS FOR ROOF & SUBFLOOR SHEATHINGLoad (psf)RoofSheathing419-10"GIRDER AND HEADER SPANS FOR EXTERIOR BEARING WALLS (DF-LARCH #2) [Table (1)] NJ = number of jacks studs Required to support each SPACING16d (3-1/2" x ")4-8d (2-1/2" x ")11326'-0"26'-0"(Ceiling attached to rafters, L/ = 240) [Table (2)]ROOF RAFTER SPANS (DF-LARCH #2)Dead load 10 psf / Live load 20 psf[Table (1) & (2)]23'-0"25'-8"CEILING JOIST SPANS (DF-LARCH #2))

3 allowable spanDead load 5 psf/ Live load 10 psf9'-10"2x411'-3"12'-5"Joist SizeSpacing12'-10" allowable span7'-2"8'-9"9'-10"14'-10"22'-11"17'-8" 19'-6"18'-9"13'-3"16'-3"Dead load 10 psf/ Live load 20 psf10'-6"16'-3"Ceiling joists not attached to parallel rafter, laps over partitionsBlocking between joists or rafters to top plateCeiling joists to plate20 FASTENER SCHEDULE [Table (1)]18'-9"22'-11"Subfloor1216 Panel edges with tongue and groove joints or with blocking043:12 Roof rafter to ridge, valley or hip rafters:Toe nailToe nailFace nailToe nail1665:12 Max.

4 Span (in.)2824 FloorTop or sole plate stud10d (3" x ")16d (3-1/2" x ")102-16d (3-1/2" x ")247 Double top plates, min. 48 inch offset of end jointsSole plate to joist or blockingBuilt-up corner studsBuilt-up header, two pieces with 1/2" spacerContinued header, two piecesContinuous header to studLedger strip supporting joists or raftersTop plates, lap at corners and intersectionsStud to sole plateFace nailDouble studsDouble top plates4-16d (3-1/2" x ")3-16d (3-1/2" x ")Wall3-16d (3-1/2" x ")Sole plate to joist or blocking at braced wall panels14'-10"2x82x102x122x64:12 Max.

5 Span (in.)3-8d (2-1/2" x ")Rafter SizeSpacingAllowable spanFLOOR JOIST SPANS (DF-LARCH #2)Dead load 10 psf / Live load 40 psf3-8d (2-1/2" x ")RoofConnectionFastenerROOF SPAN(FT.)RemarksRAFTER SLOPE2x62x82x10[Table (2)](Dead load 10 psf; Panel continuous over two or more spans w/ long dimension perpendicular to supports; Applies to panels 24" or wider) [Table (1)]Joist sizeSpacingAllowable span126815123562447951258 GIRDER AND HEADER SPANS FOR INTERIOR BEARING WALLS (DF-LARCH #2) [Table (2)] NJ = number of jacks studs Required to support each ' Building width28' Building width8-16d (3-1/2" x ")16d (3-1/2" x ")3-10d (3" x ")Toe nail10d (3" x ")10d (3" x ")2-16d (3-1/2" x ")2-10d (3" x ")24" " along each edge16" along each edgeToe nailFace nail 24" each layer as follows: 32" at top and bottom and staggered.

6 Two nails at ends and at each nail 24" nail in lapped areaFace nail 16" " to sill or girderRim joist to top plate (roof application also)16d (3-1/2" x ")3-8d (2-1/2" x ") or2-16d (3-1/2" x ")At each joist or rafterEnd nailFace nailToe nailToe nailBuilt-up girders and beams, 2-inch lumber layers3-8d (2-1/2" x ")8d (2-1/2" x ")10d (3" x ")Toe nail 6" 2 INTERMITTENT BRACING METHODS BASED ON SEISMIC DESIGN CATEGORY (AS A FUNCTION OF BRACED WALL LINE LENGTH)a ROOF/CEILING DEAD LOAD = 15 PSF WALL HEI GHT = 10 FT FLOOR DEAD LOAD = 10 PSF BRACE D WALL LINE SPACING = 25 FT SOIL CLASS D MI NI MU M TOT AL LENGT H (feet ) OF BR ACED WALL PANELS Required ALONG EACH BRACED WALL LINEe Seismic Design Category (SDC) Story Location Braced Wall Line Length Met hods GBb and PCPc Met hod W SPd SDC D0 or D1 1084201243018640248503010 SDC D2 S I: 1 foot = mm, 1 pound per square foot = Pa.

7 A. Based on Table (2) of the 2011 County of Los Angeles Residential Code. b. GB = 1/2 minimum thickness gypsum board with 1 1/2 galvanized roofing nail or 1 1/4 screws, Type W or S for exterior sheathing, or 5d cooler nail, diame ter, 1 5/8 long, 15/64 head for interior sheathing. Maximum spacing of fasteners shall be at 7 on center, at panel edges including top and bottom plates. When Method GB panel s are applied to only one face of a braced wall panel, the minimum total length of braced wall panel in the Table shall be doubled. c. PCP = 7/8 minimum thickness portland cement plaster with 1 1/2 , 11 gage, 7/16 head nails at 6 spacing.

8 (For maximum 16 stud spacing only.) Gypsum wall board (1/2 minimum thickness) shall be installed on the side of the wall opposite the bracing material, except if the mi nimum total length of braced wall panel in the Table is multiplied by a factor of d. WSP = 15/32 minimum thickness wood structural panel with 8d common (2 1/2 x ) nails at 6 spacing (panel edge) at 12 spacing (intermediate supports), 3/8 edge distance to panel edge. Gypsum wall board (1/2 minimum thickness) shall be installed on the side of the wall opposite the bracing material, except if the minimum total length of braced wall panel in the Table is multiplied by a factor of e.

9 Method GB and PCP braced wall panel h/w ratio shall not exceed 1:1.