Example: bankruptcy

RESIDENTIAL BUILDING REPORT

34 Raleigh St WINDSOR REPORT Prepared: 2 August 2013 RESIDENTIAL BUILDING REPORT 1300 776 072 Box 2129, Richmond South, VIC 3121 1300 776 072 Box 2129, Richmond South, VIC 3121 Bear Bottom Inspection Copyright RAPID Solutions 2002 Page 2 of 44 Pages PRE-PURCHASE INSPECTION RESIDENTIAL BUILDING REPORT Complies with Australian Standard AS 2007 Inspection of Buildings Part 1: Pre-Purchase Inspections RESIDENTIAL Buildings Appendix C (For use in all States & Northern Territory but not the Australian Capital Territory) ADMINISTRATION DETAILS Property Address: 34 Raleigh St, WINDSOR AGREEMENT DETAILS The purpose of the inspection is to identify the major defects and safety hazards as

RESIDENTIAL BUILDING REPORT 1300 776 072 P.O. Box 2129, Richmond South, VIC 3121 ... The Building and the Site including fences that are up to 30 metres from the ... There is evidence of timber pest activity (borer- Furniture Beetle) and/or …

Tags:

  Residential, Timber, Fence

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of RESIDENTIAL BUILDING REPORT

1 34 Raleigh St WINDSOR REPORT Prepared: 2 August 2013 RESIDENTIAL BUILDING REPORT 1300 776 072 Box 2129, Richmond South, VIC 3121 1300 776 072 Box 2129, Richmond South, VIC 3121 Bear Bottom Inspection Copyright RAPID Solutions 2002 Page 2 of 44 Pages PRE-PURCHASE INSPECTION RESIDENTIAL BUILDING REPORT Complies with Australian Standard AS 2007 Inspection of Buildings Part 1: Pre-Purchase Inspections RESIDENTIAL Buildings Appendix C (For use in all States & Northern Territory but not the Australian Capital Territory) ADMINISTRATION DETAILS Property Address: 34 Raleigh St, WINDSOR AGREEMENT DETAILS The purpose of the inspection is to identify the major defects and safety hazards associated with the property at the time of the inspection.

2 The inspection and reporting is limited to Appendix C The REPORT does not include an estimate of the cost for rectification of the Defects. The overall condition of this BUILDING has been compared to similarly constructed and reasonably maintained buildings of approximately the same age. Agreement Number: 12501 Date of Agreement: Friday, 2 August 2013 Time of Agreement: 7:47am _____ Specific requirements/conditions required by You were: Not Applicable Changes to the inspection agreement requested: Not Applicable Date the changed agreement was accepted: Not Applicable Time the changed agreement was accepted: No Changes NOTE: This REPORT should not be relied upon if the contract for sale becomes binding more than 30 days after the date of initial inspection.

3 A re-inspection after this time is essential. Bear Bottom Inspection Copyright RAPID Solutions 2002 Page 3 of 44 Pages INSPECTION DETAILS Date of the inspection: 2 August 2013 Time of inspection: 9:30am Persons in attendance: Agent Vendor _____ Weather conditions at the time of inspection: Dry Comments: None Recent weather conditions: Dry and wet periods Comments: None BUILDING furnished: Yes Comments: Furnishings, pictures, wall coverings, and personal item storage prevented a full visual inspection of all areas.

4 Conditions can change between the time of inspection and settlement. The client is advised to perform a careful check of all areas during the final walk through. The client is also advised to note any staining or conditions that may not have been visible during the time of inspection. Such conditions should be brought to the attention of the selling agent, vendor and/or the vendors solicitor prior to settlement of this property. BUILDING tenancy: Occupied Comments: None AREAS INSPECTED AND RESTRICTIONS TO THE INSPECTION The inspections included: The BUILDING and the Site including fences that are up to 30 metres from the BUILDING and within the boundaries of the Site.

5 The Actual Areas Inspected Were The BUILDING interior The BUILDING exterior The roof space The roof exterior The site Restrictions (a) Areas NOT inspected including reason(s) were: The subfloor o The entire subfloor area was unable to be inspected as there was not suitable access and/or crawlspace. The subfloor was only viewed from (limited to) the exterior perimeter. Access should be granted to provide a thorough visual inspection of the entire subfloor area. Bear Bottom Inspection Copyright RAPID Solutions 2002 Page 4 of 44 Pages (b) Areas NOT FULLY inspected including reason(s) were: The roof space o The southern section of the roof is a combination of a cathedral and skillion style roof.

6 Due to the design of the roof, there is no roof space. The roof frame and interior was unable to be inspected without removing the roof covering, which is outside the scope of this inspection. Access should be granted to provide a thorough visual inspection to take place. RECOMMENDATIONS TO GAIN ACCESS AND REINSPECT The area(s) and/or section(s) to which Access should be gained or fully gained are: The entire roof space The entire subfloor Further Inspection and Reporting of these areas is Essential once access has been obtained and prior to a Decision to Purchase to determine if any major defect/safety hazard exists in these areas/sections.

7 Bear Bottom Inspection Copyright RAPID Solutions 2002 Page 5 of 44 Pages FACTORS THAT INFLUENCED THE INSPECTION/ REPORT OUTCOME Limitations to the Inspection, apart from Access Issues noted above, and how these limitations, have affected the Inspection and/or the preparation of the REPORT : The limitations were: None Details of apparent concealment of possible defects: No visual sign of apparent concealment observed Information provided to the Inspector that has a bearing on the Inspection and/or REPORT and from whom and when that information was provided: There was no additional information provided Details of Other Factors influencing the inspection.

8 None Description and Identification of the Property Inspected Type Free standing domestic house Style Single storey Construction Type Double Brick / Cavity Brick Weatherboard Construction- timber framing with weatherboard cladding in southern section Interior Lathe and Plaster Plasterboard Rendered brickwork timber wall panelling Piers Hardwood stumps as viewed from the perimeter only Flooring (Interior) Combination of tongue and groove pinewood and hardwood sections. Tongue and groove sheet particle board Tile Carpet Verandahs Verandah located at the front of the property Roofing Combination of skillion roof and a hardwood pitched roof Roof Covering Slate Metal roofing Out Structures Not applicable Bear Bottom Inspection Copyright RAPID Solutions 2002 Page 6 of 44 Pages Other Inspections and Reports Required It is Strongly Recommended that the following Inspections and Reports be obtained prior to

9 Any decision to purchase the Property and/or before settlement. Obtaining these reports will better equip the purchaser to make an informed decision. Terminology The Definitions below apply to the TYPES OF DEFECTS associated with individual items/parts or Inspection areas. Damage The BUILDING material or item has deteriorated or is not fit for its designed purpose Distortion, Warping, Twisting The Item has moved out of shape or moved from its position Water Penetration, Dampness Moisture has gained access to unplanned and/or unacceptable areas Material Deterioration The item is subject to one or more of the following defects.

10 Rusting, rotting, corrosion, decay Operational The item or part does not function as expected Installation The installation of an item is unacceptable, has failed or is absent Important: Strata Title - Where an item in the inspection findings below is noted as being part of the Common Area, the item is outside the Scope of this REPORT . It is strongly recommended that an Inspection and REPORT on these areas be obtained prior to any decision to purchase the Property and/or before settlement. Obtaining these reports will better equip the purchaser to make an informed decision.