RHEYHALON Series 911 Special Navy Cables - Nexans

RHEYHALON Series 911 Special navy CablesIssue 01/2004In future will be changed the colour code for power Cables type MGSGO and LMGSGOE xisting colour codeFutural colour code2 cores3 cores4 cores5 coreswith gn/yewithout gn/ye2 cores3 cores4 cores5 coreswith gn/yewithout gn/yeSpecial Cables MarineDefence- or war-ships are complexplatforms with a number of inter-dependent systems and a consequence, the navy ,governmental agencies and systemdesigners have to deal with a largerange of variables and parameters;moreover, most of the different militaryspecified variables also have asignificant effect on how the systemwill perform or designed or midlife convertedwarships are made-to-order forces the user, the projectmanagement and the team ofdesigners to combine and harmonizea large amount of different partlyco

Special Cables Marine Defence- or war-ships are complex platforms with a number of inter-dependent systems and subsystems. As a consequence, the Navy,

Tags:

  Navy, Series, Special, Cable, Rheyhalon series 911 special navy cables, Rheyhalon, Special cables

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of RHEYHALON Series 911 Special Navy Cables - Nexans

1 RHEYHALON Series 911 Special navy CablesIssue 01/2004In future will be changed the colour code for power Cables type MGSGO and LMGSGOE xisting colour codeFutural colour code2 cores3 cores4 cores5 coreswith gn/yewithout gn/ye2 cores3 cores4 cores5 coreswith gn/yewithout gn/yeSpecial Cables MarineDefence- or war-ships are complexplatforms with a number of inter-dependent systems and a consequence, the navy ,governmental agencies and systemdesigners have to deal with a largerange of variables and parameters;moreover, most of the different militaryspecified variables also have asignificant effect on how the systemwill perform or designed or midlife convertedwarships are made-to-order forces the user, the projectmanagement and the team ofdesigners to combine and harmonizea large amount of different partlycontroversial requirements, specifiedand progressively tightened by case of electric/electronic systemson board the overall objective of thework is to intervene the differentmodules in most cases by Cables .

2 Allmajor NATO members independentlyhave tithed rules on navy Cables withrespect to toxic and hazardous by-products in case of fire, cross linking,shielding efficiency, cross talk, wireidentification etc. Non of the militaryspecifications are the size and weight optimisedRheyhalon navy Cables , in accor-dance with VG 95218 part60 - 66, listed in this catalogue arefree of halogens and correspondsimultaneously with all requirementsof naval ship design and constructionrules of the German navy (BV 3400). RHEYHALON navy Cables are matchingand exceeding also internationalspecification requirements of low firehazard, limited fire hazard and lowsmoke navy the beginning of the demandfor cross-linked, halogen free Navycables Nexans Deutschland IndustriesGmbH & Co.

3 KG as predecessor ofAlcatel Kabel, Kabel Rheydt andAEG Kabel has been developing,manufacturing and supplying morethan 13,000 km of Cables accordingto VG 95218 part 60 (50) through66 (56) for the German and catalogue seeks to address asolution in a context of concurrentengineering, with active linkagebetween international design variablesand processing cable this catalogue all other catalogueissues for navy Cables according toVG 95218 of ReferenceRHEYHALON navy CablesShip typeQuantityCountryFrigate F1228 GermanyFrigate MEKO 200 TN4 TurkeyFrigate MEKO 200 PN3 PortugalFrigate MEKO 200 HN3 GreeceFrigate F1234 GermanyFrigate F1243 GermanyMinesweeper SM 34310 GermanyMinesweeper MJ 33212 GermanyServiceboats FD 4233 GermanyTender 4046 GermanyP-Boats P2004 BrasilFrigate MEKO 200 TN2 TurkeyTorpedo Boats5 TurkeyTorpedo

4 Boats4 IndonesiaSubmarines U 206 A10 GermanySubmarines2 TurkeySubmarines SK-Class9 KoreaSubmarines DOLPHIN3 IsraelDiverse maintenanceAustraliaSingaporeThailandInd iaColombiaChileGreeceRSANew ZealandArgentinaPeruTask Force Supply Vessel2 GermanySubmarines U2124 GermanyCurrent ProjectsSubmarines U2144 GreeceModernisation U2093 GreeceSubmarines U2093 RSAC orvettes4 RSAS peedboats KILIC II6 TurkeyMinesweeper MHV6 TurkeySubmarines U 2093 TurkeyFrigate F-3105 NorwayOPV6 MalaysiaOPV3 Thailand4 Comparation Listold and new discriptions acc. to VG 95218 navy CablestypeVG 95218oldRHEYHALON-discriptionsdiscriptio nacc.

5 To VG 95218 Power - navy Cableswith or without overall screen and defined transfer impedancepart 60 MGCGMGSGOL ight Power - navy Cableswith overall and defined transfer impedancepart 61 LMKKLMGSGOT elecommunication - navy cableswith twisted pairs, overall screen and defined crosstalk attenuationpart 62 LFMKKFMGSGOT elecommunication - navy cableswith screened pairs, overall screen and high crosstalk attenuationpart 63 XLFMKKFMSGSGOL ight Telecommunication - navy cableswith twisted pairs, double overall screen and defined crosstalkattenuation, low transfer impedancepart 64 LSKLFMGSSGOL ight Telecommunication - navy cableswith screened pairs and overall screen, high crosstalk attenuationand defined transfer impedancepart 65 LSKCLFMSGSGOL ight Telecommunication - navy cableswith screened triples and double overall screen, high crosstalkattenuation, low transfer impedancepart 66 LSKCLFMSGSSGO56 ApplicationsRHEYHALON navy Cables aredetermined for fixed installationin electrial power- and controlsystems below and above deck.

6 Preferably on ships of the GermanNavy and/or German design ofconstruction. These Cables are notintended for permanent installationin or under navy Cables fulfillall requirements of BV3400( Specification for Construction ofGerman navy vessels ).Design1. ConductorBare copper conductor, stranded class 2 or class 52. InsulationInsulation of crosslinked EPR3. Filling compound4. Screen (not type MGGO)Bare copper wire braided screen, separator tape (optional)5. Outer SheathOuter sheath of crosslinked elastomer compound, colour blackMarkingColour of outer sheath black, marked by printing in contrast-colourSample:l Nexans l D 0768 9254 RHEYHALON - Series 911 VG 95218 T060 A002 MGSGO 1x6 kVCore Identification1-core cableblack2-core cableblack-blue3-core cableblack-blue-brown4-core cableblack-blue-brown-black7 StandardsVG 95218 part 60 MGGO and MGSGOacc.

7 To VG 95218 part 60 With or without overall screen and definedtransfer impedance, halogenfree, crosslinkedMax core temperature: 85 kVApproval/ CertificatesFor these RHEYHALON Navycables following certificates/approvals are available:- BWB Certificate of Approval according to VG 95211- VDE Certificate of conformity with manufacturing surveillance- Approval Certificate from Germanischer Lloyd - Approved QPL manufacturer according to VG 95212-22- Certified manufacturer according to ISO 9001 MGGO and MGSGO kV acc. to VG 95218 part 60 NomenclatureNumber ofDiameter ofWallWallOuterCable-Current andconductorthickness ofthicknessdiametersWeightat ambientVG 60cross sectionnominalnominalof 45 CType/Part , , , , , ,240690A0151x185 rf 2) ,192520*1x95 ,160350*1x240 , , , , , , , , , 3) 3) 3) ,15090 3) ,670120 3) ,155145 3) ,755180 3) ,740225 3) ,980280 3)1) Type C = MGGO without screen2) = flexible design with fine stranded wire conductor (class 5)3)

8 = only 3 cores loaded, core 4 = earth core* not VG-types8 MGGO and MGSGO to VG 95218 part 60 Electrical and mechanical characteristicsNominal VoltageUo/U = / 1 kVTransfer impedancemax. 30 m /m at 10 MHz (Type A and B/MGSGO)Max. permissible operating voltage AC 1,200 V DC 1,800 VOperating temperature at conductor + 85 CMinimum bending radius during installationType A Part-No. A001-A0145 x outer diameterPart-No. A0154 x outer diameterType B Part-No. B001-B028, B0305 x outer diameterPart-No. B029, B0314 x outer diameterType C Part-No.

9 C0015 x outer diameter Part-No. C002 4 x outer diameterLowest permissible temperature for installation- 10 CCurrent ratingThe values for current carrying capacity, listed in the tables, correspond to the values in BV 3400 ( Specification for Constructionof German navy vessels ). This values are given for continuous operating and single installation at ambient temperature of 45 higher ambient temperatures, following factures have to be used for calculation:Ambient temperature:45 CDerating ofDiameter ofWallWallOuterCable-Current andconductorthickness ofthicknessdiametersWeightat ambientVG 60cross sectionnominalnominalof 45 CType/Part rf 2) , rf 2) ,300280*3x70 ,000225C0011x150 1) ,600460C0021x185 1) 2) ,1925201) Type C = MGGO without screen2) = flexible design with fine wire conductor (class 5)3)

10 = only 3 cores loaded, core 4 = earth core* not VG-types9 ApplicationsRHEYHALON navy Cables aredetermined for fixed installationin electrial power- and controlsystems below and above deck,preferably on ships of the GermanNavy. These Cables are not in-tended for permanent installationin navy Cables fulfillall requirements of BV3400( Specification for the Constructionof German navy vessels ) for lightpower degaussing- and Navycables with improvedcharacterstics in case of ConductorBare copper conductor, stranded class 22. InsulationInsulation of crosslinked HEPR3.