1 Data Sheet rish insu 10 1 of 3 Version: 1/08/III/1211/ BAnalog - Digital Insulationand Continuity 2 of 3 Version: 1/08/III/1211/ BApplicationsFeaturesRISH Insu10 Analog-Digital Insulation and Continuity Tester is suitable for followingMeasurement of the insulation resistance on electrically dead equipment and systems with test voltages up to testing motors, transformers, generators, testing of house hold of the insulation resistance of useful for on-site maintenance and service Voltages 50V/ 100V/ 250V/ 500V/ 1000 VTest voltages from 50V to 1000V can be selected for Insulation Resistance measurement. It covers all insulation tests up to Resistance MeasurementThe instrument is capable of measuring insulation resistance from 10 K.
2 999 M .Hands-free continuity testingContinuity testing (0-10 with acoustic signal) can be done without pressing the test button. In addition to the display function, an acoustic signal can be activated which sounds if the adjustable limit value is Instrument measures voltages > 25V .. 600 V discharge for capacitive circuits after testmeasurementCapacitive devices under test, such as cables and windings, that get charged during the test, are discharged by the circuit detectionDisplays presence of voltages >25V irrespective of function measurement time for Insulation Resistance MeasurementIn normal course, the insulation test terminates and the measured insulation resistance value remains on display for 2 sec after the test key is released.
3 With the Pre-selectable measurement time feature, the insulation test continues and the measured value remains on the display for the pre-determined time. Pre-selectable time: 10 sec - 5 limit checks (Go/ No-go option) for M An acoustic signal can be generated when the measured value ofinsulation resistance falls below an adjustable limit resistance null facilityThe instrument provides a facility to compensate the resistance of the leads for an accurate measurement of low of MIN/MAX valuesIn addition to the display of the actual measured value, the minimum or maximum value can constantly be updated or Memory for last 50 readings The instrument provides a facility to store and recall 10 values in each of the 5 ranges of insulation resistance fuse indicationThe display FUSE points to a blown battery indicationAutomatic display of the Symbol when battery cells are Watch This function allows you to measure elapsed time up to 1 off function The instrument turns off automatically.
4 If any of the keys or the selector switch have not been activated for about 10 minutes in insulation range and 5 minutes in other ranges or can be switched to continuous holster for rough dutyA holster of soft rubber with tilt stand protects the meter against damage in the case of shock and Resistances Measurement ( .. ) Low resistances can be measured up to . There are two measuring ranges for Low .: and 1) For Insulation Resistance Range: Terminal voltage on open circuit (DC)-0% + 30% of rated voltage Short circuit current < 2 mA Test current on load 1 mA at minimum pass values of Insulation as specified in VDE 0413 Part ) For Low Ohms/Continuity Ranges: Lead Resistance Compensation: 0 - Open circuit voltage 5V + 1V SupplyBattery6 x V cells IEC LR6 (Nickel cadmium rechargeable cells may be used)Service LifeTypically 2500 x 5 sec.
5 OperationsBattery Test Automatic display of the Symbol when battery voltage < : Battery cells should not be left in the instrument which may remain unused for extended period of Coefficient < per COperating +40 C (full range)-20 +60 C (upto 100M )Storage +65 CRelative Humidity 90% RH at 40 C max. Environmental conditions0 to =50V,Low OhmsContinuityM N100V1)1)InsulationResistanceU =250V,M N500V,1000V1)1) 2) >10 to at210 mA at21 mA at210 mA + 3% + 2D+ 5% + 2D0 to + 3% + 2D2)V AC/DC25V to 450V450V to 600V>100 M to999M > M M M M >10 M to99 M > M M M M Range1V1V 1 M 100 K( M ) 10 K( M ) 1 M 100 K( M ) 10 K( M ) + 2% + 3D+ 3%+ 30%service error+ 5% + 2D+ 3% + 2D+ 30%+ 5% + 2D+ 3% + 2 DResolutionAccuracy+(.
6 % of rdg+ ..Digit)Overloadvalue &duration1200 Vrms10 sec1200 Vrms10 sec1200 Vrms10 sec1200 Vrms10 sec1200 Vrms10 secSpecification at21 mA + 5% + 2D>10 to DisplayLCD display field (65 mm x 30mm) with analog indication and digital display and with display of unit of measured quantity and functionsAnalogDisplayLCD scale with bar graphScale Length47 with 30 graduationsOverflow DisplayBar with segment digits/ 12mmNumber of Digits3 digit for M and 4 digit for Stop watchOverflow DisplayReference ConditionsAmbient Temp. +23 C + 2 KRelative Humidity 45% .. 55%Battery Voltage 8V + Measurement AC (Sine), 50/60 HzAuto turn OFFM eter turns off automatically, if any of the keys or the selector switch have not been activated for about 10minutes in insulation range and 5 minutes in other ranges.
7 Fuse 500 mA (F) / 440V min (32mm x 6mm)IEC/EN61326 Electromagnetic Compatibility (EMC)Protection class II per IEC 61010-1/EN61010-1/VDE0411-1 OvervoltageCategory II IIIN ominal Voltage 600V 300 VContamination degree 2 2 Test Voltage IEC 61010-1 /EN61010-1 ProtectionInstrument : IP 50 For terminal socket : IP 20 according to DIN VDE 0470 part 1 / EN60529 Dimensions W x H x D84 mm x 195 mm x 35 mmWeight500 g including battery OLApplicable standardsEMCE lectrical SafetyMechanical DesignElectromagnetic Compatibility (EMC)Digital measuring instrumentsSafety regulations for electrical measuring,control, regulation and laboratory devicesDevices for testing, measuring and monitoringprotective safety measures in system withvoltages of upto 1000 V and 1500 V Insulation resistance measuring Instruments - Low-resistance measuring instrumentsTest Instruments and test proceduresDegree protection provided by enclosures (IP code)
8 IEC/EN 61010 - 1 VDE 0411 - 1 IEC/EN 61557 VDE 0413 Part 2 IEC/EN 61 326 VDE 0470-Part1 Part 1 Part 3 DIN 43751EN 60529- General requirementsRISHABH Instruments , MIDC, Satpur, Nashik-422 007, : +91 253 2202160, 2202202 Fax : +91 253 2351064E-mail : India :- International :- 3 of 3 Version: 1/08/III/1211/ B