ROSS PV OC SC ST ROSS STANDARD ADVANTAGES: …

ross PV OC SC ST ross . STANDARD ADVANTAGES: FEATURES: Piston Style Design is Technical Resources: Automatic Control valves for the 1 Rigid Piping 3 not vulnerable to sudden Water and Wastewater Industries 2. & Fittings failures At ross Valve, we pride ourselves in providing a truly engineered product. 1. 2 Position Indicator All manufacturing done There is no off the shelf valve that will perform optimally in every appli- in-house (Troy, NY) for cation, so we specify at least 10 separate criteria to ensure the best 3 Strainer with 7 in2 quality control 5 performance possible for each valve. With nearly 130 years of industry Stainless Steel Filter 100% Hydraulic testing experience, ross Valve offers a variety of in-house resources to ensure all 4 Application-Specific on every valve before Seat Contour your product requests are met: shipment 4. 5 ANSI Class 250. OUTLET. Extra-heavy construction, Dynamic Fluid Modeling INLET.

Direct Acting, ½”-1-½” [T-Series] made Automatic Control Valves that were designed to last. *.

Tags:

  Standards, Valves, Advantage, Ross, Sc st ross standard advantages

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of ROSS PV OC SC ST ROSS STANDARD ADVANTAGES: …

1 ross PV OC SC ST ross . STANDARD ADVANTAGES: FEATURES: Piston Style Design is Technical Resources: Automatic Control valves for the 1 Rigid Piping 3 not vulnerable to sudden Water and Wastewater Industries 2. & Fittings failures At ross Valve, we pride ourselves in providing a truly engineered product. 1. 2 Position Indicator All manufacturing done There is no off the shelf valve that will perform optimally in every appli- in-house (Troy, NY) for cation, so we specify at least 10 separate criteria to ensure the best 3 Strainer with 7 in2 quality control 5 performance possible for each valve. With nearly 130 years of industry Stainless Steel Filter 100% Hydraulic testing experience, ross Valve offers a variety of in-house resources to ensure all 4 Application-Specific on every valve before Seat Contour your product requests are met: shipment 4. 5 ANSI Class 250. OUTLET. Extra-heavy construction, Dynamic Fluid Modeling INLET.

2 Body & Caps for decades of reliable Pattern Shop & 2 Foundries 6 NSF 61 Certified service Epoxy Coating Machine Shops & CNC Centers Over 10 criteria specified Inside & Out 7 for every valve to ensure Hydro Test Facilities 6 optimal performance 7 Fully Guided Piston Pre-Packaged Vault Design/Build Center Above & Below Seat Low maintenance, easily Online Tools customizable Animated Valve Operation Schematics OPERATION: Valve Sizing / Capacity Tool The ross Valve piston-style design provides extremely accurate flow control and is not subject to Valve Configuration Tool sudden failure. Each valve is comprised of the following STANDARD components: (For customized Specifications, Submittals, Operation & Maintenance Manuals). OC The Operating Chamber is created by the top seals of the piston. The pressure in this chamber, as determined by the control components, determines the movement of the piston.

3 ST Our STANDARD Strainer utilizes a stainless steel screen with over 7 square inches of surface area to filter out contaminants going into the valve controls. SC The adjustable Speed Control Valve regulates the flow into the Operating Chamber and deter- mines the main valve's opening and closing speeds. PV The Pilot Valve, whether hydraulic or electric, acts like the brain of the valve to determine when the valve will open or close. OPENING CLOSING. When the Pilot Valve When the Pilot Valve opens, fluid exits the closes, fluid continues Operating Chamber to enter the Operating faster than it can enter Chamber through the through the Speed Strainer and Speed ross Valve Mfg. Co., Inc. OUTLET. OUTLET. Control Valve. The low Control Valve. The high Box 595, Troy, NY 12181-0595, USA. INLET. INLET. pressure created in the pressure created in the Tel: 518-274-0961 Fax: 518-274-0210.

4 Operating Chamber Operating Chamber Email: ross Valve manufactures all its allows line pressure in overcomes the line products in Troy, NY. Our corporate the main valve to force pressure in the main valve All ross valves meet or exceed all headquarters are now located in the the Piston up, opening and forces the Piston current AWWA standards for the valve. down, closing the valve. newly expanded ross Tech Park, construction and pressure ratings. just miles from our original facility. Note: Renderings shown are for reference only and are subject to change at any time. Engineering drawings are provided during the submittal process. RV 06-10 5000. Company History When George ross founded our company in 1879, he made Automatic Control valves that were designed to last. CONSIDERATIONS. He also created a company built on enduring values: integrity FUNCTIONAL FEATURES. HYDRAULIC ELECTRIC MECHANICAL.

5 1E = All External Controls (Small valves ). of design and engineering, quality of materials, craftsmanship A = Surge Control (Hydraulic Trigger). ACAV = Anti-Cavitation Trim in manufacturing, a high level of customer service, and ACTUATION ACTUATION ACTUATION. ACAV3 = Anti-Cavitation Trim (3-Stage). AL = Altitude Pilot flexible business systems that have evolved with changes in AP = Auxiliary Pilot BP = Back Pressure Sustaining Pilot technology and the industries we serve. CE = Check Feature (External). CI = Check Feature (Internal). Pilot Operated, 4 -48 [40WR] Solenoid Operated, Throttling, 4 -48 [42 AFCV-PT]. Still located in Troy, NY, ross Valve has grown to become Pilot Operated, 1 -3 [23WR]. DO = Delayed Opening DP = Differential Pilot Build a valve E = Surge Control (Electric Trigger). an internationally renowned manufacturer, and expanded to Direct Acting, 1 -4 [98EP] to your specifications, EC = Emergency Quick Close ELA = Electric Actuator a second facility in 2004 to better serve our customers.

6 As a Direct Acting, -1- [T-Series] or get additional details EX = Exhaust Feature - to open main valve HYC = Hydraulic Cylinder 5th generation family-owned and operated business, there is Pilot Operated, Two-Way Flow, 4 -48 [40 DAWR] Remote Float/Pilot Operated, 4 -48 [45 FWR]. and drawings, using LD = Low Differential Design Solenoid Operated, Throttling, 4 -48 [42 AFCV-L] LFBP = Low Flow Bypass an intense commitment to assure that all of our equipment is Pilot Operated, Elevated Tank, 4 -48 [30 AWR] Solenoid Operated, On-Off, 4 -48 [50 FWR] Float/Lever Operated, 4 -48 [21F]. our Interactive Catalog MB = Manual By-pass MGA = Manual Gear Actuator and online Product top quality and meets the high expectations of our customers. Pilot Operated, Ground Tank, 4 -48 [40 AWR] Float/Lever Operated, 1 -3 [20F]. Configurator at MSC = Manual Stop: Limits Closing MYS = Yoke Stop: Limits Opening With its rugged piston-style design, a ross Valve offers Pilot Operated, Pressure Reducing, 4 -48 [42 WRS-40WR] Solenoid Operated for Booster Pump, 4 -48 [42 WRS] PR = Pressure Reducing Pilot R = Reverse Flow unparalleled long-term value and customizability Pilot Operated, Pressure Sustaining, 4 -48 [42 WRS-50 RWR] Solenoid Operated for Deep Well Pump, 4 -48 [45WR] REL = Relief Pilot REM = Remote Pilot RF = Rate of Flow Pilot for any application.

7 This has earned us the reputation as a SAC = Spring Assembly: Closing Assist Pilot Operated, 4 -48 [50 RWR] SAO = Spring Assembly: Opening Assist manufacturer of the industry's most durable and accurate Internal Pilot Operated, 1 -3 [23 RWR]. SC = Solenoid Pilot Valve: 2-way SF = Solenoid Pilot Valve: 3-way Open Automatic Control valves . main valve when energized SG = Solenoid Pilot Valve: 3-way Open Pilot Operated, 4 -48 [50 RWR] main valve when de-energized Internal Pilot Operated, 1 -3 [23 RWR] Cavitation damage SL = Slow Close Pilot ross valves Last Longer Original piston-style ross Valve, circa 1900. While Internal Pilot Operated, 1 -3 [20WR] can destroy a valve SO = Solenoid Pilot Valve: 2-way [Emergency Close]. our product has evolved, the rugged design remains and the surrounding TDC = Top Differential Cylinder VB = Vacuum Breaker largely unchanged, even today. Pilot Operated, Electric Trigger, 4 -48 [50 RWR-E] equipment.

8 Protect your Our hand-crafted valves are designed with features that Pilot Operated, Hydraulic Trigger, 4 -48 [50 RWR-A]. OPTIONAL ACCESSORIES. investment with our differentiate us from all other control valves , and our quality optional WaterTamer Anti- ASF = Automatic Strainer Flush AX = 2-Point Active Pressure Control Pilot Operated w/ Orifice Assembly, 4 -48 [40RF]. standards ensure that a properly maintained ross Valve Dedication to Pilot Operated w/ Orifice Assembly, 1 -3 [23RF]. Solenoid Operated, Throttling, 4 -48 [42 AFCV] Cavitation feature. BD = Blow Down Feature (Strainers). CP = Pump Control Panel - Mechanical Relay is often an investment that will last a lifetime. To provide [ACAV & ACAV3]. Quality DATA = Datalogger Package DES = Dual High Efficiency Strainers assistance through the decades of use, the following services Cushioned, 4 -48 [43WR] Electric Check, 4 -48 [42 WRS] DPG = Dual Pressure Gauges DLS = Dual Limit Switches are a STANDARD part of every ross Valve purchase: Based in Troy, NY since 1879, ross Differential Pressure, 4 -48 [40DP], Operates on increasing differential DN = Dual Speed Control valves DS = Dual Strainers We will maintain a detailed record of the individual Valve continues to do all manufacturing Emergency Cut-In, 4 -48 [37WR], Opens on falling outlet pressure ES = High Efficiency Strainer Emergency Line Break, 4 -48 [37WR-DP], Closes on flow increase FAK = Flange Gasket/Assembly Kit valve's construction, settings, and service history in-house so that we may provide our FC = Float Chamber H = Hydrant Connection (2-1/2 Fire Valve).

9 Solenoid Operated Throttling, 4 -48 [42 AFCV]. Dedicated, factory-trained service technicians available customers with the following: Manually Operated, 4 -48 [42WR-MAN]. IR = Indicator Rod (Small valves ). Solenoid Operated, 4 -48 [42WR] LPT = Linear Potentiometer Transmitter for on-site start-ups and service 100% quality control, from product Solenoid Operated, 1 -3 [3902] Pre-Packaged Vaults LR = Latching Relay: Stays closed until manual override combine the quality and LS = Limit Switch Live, personal assistance for remote troubleshooting and design through final testing reliability of a ross Valve MC2000F = Flow Control Panel Energy Dissipating, Fixed, 2 -120 [890]. maintenance questions Performance-tuned valves , with at Energy Dissipating, Hydraulic Actuator, 4 -90 [MOV-HC] Energy Dissipating, Electric Actuator, 4 -90 [MOV-EA] Energy Dissipating, Manual Actuator, 4 -90 [MOV-MG] with the convenience of a MC2000L = Level Control Panel MC2000PT = Pressure Control Panel MC2000VP = Valve Position Panel professionally designed and Customizable Operation & Maintenance manuals are least 10 independent criteria speci- MC2001P = Pump Control Panel - PLC Based factory tested station.

10 MP = Reversible Electric Motor (for Pilot Valve). available online anytime fied for optimal performance in each Basket Type, 4 -48 [10B] PG = Pressure Gauge PI = Pipe Inserts A preventative maintenance schedule tailored to your application Basket Type, 2 -3 [10C] PS = Pressure Switch Strainers - Cartridge Type, -1 [5F2] RPT = Rotary Potentiometer Transmitter valve can be provided Durable and flexible designs, for a SI = Setting Indicator SPEC = Special Feature lifetime of service - even if operating TD = Time Delay Internal Pilot Operated, 1 -3 [20WR-PRV] TF = Traveling Float conditions should change Our Customers TOP = Top Piping Configuration TP = Timer Package Lead time management and manufac- MATERIAL UPGRADES. Internal Pilot Operated, 1 -3 [20WR]. ross continues to grow its turing flexibility for both STANDARD and Internal Pilot Operated, Hydrant Connection, 1 -3 [20WR-H] CS = Chrome Superstructure (FireValves).