Example: quiz answers

Rotary Blower Packages BB, CB, DB, EB, FB Series

Delivery to 74 m /min Pressure up to 1000 mbar, Vacuum to 500 mbarRotary Blower PackagesBB, CB, DB, EB, FB SeriesWith the world-renowned OMEGA until:2222222222222222222222222222222222 2222222222222222222222222222222222222222 222 Valid until:Integrated engineering COMPACT Series Rotary Blower Packages are deliv-ered complete with sound enclosure and integrated electrical equipment (optionally available as star-delta starter or variable speed control). All electrical equip-ment is sized according to required performance data and is wired and programmed for EMC compatibility as per applicable and safety Using numerous sensors, the internal SIGMA CONTROL 2 monitors and controls all parameters essential to reliable and effi cient Blower system oper-ation. Available remote monitoring and control further enhance Blower availability.

www.kaeser.com Air delivery 1.5 to 74 m³/min – Pressure up to 1000 mbar, Vacuum to 500 mbar Rotary Blower Packages BB, CB, DB, EB, FB Series With the world-renowned OMEGA PROFILE

Tags:

  Blower, Rotary, Packages, Rotary blower packages bb

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Rotary Blower Packages BB, CB, DB, EB, FB Series

1 Delivery to 74 m /min Pressure up to 1000 mbar, Vacuum to 500 mbarRotary Blower PackagesBB, CB, DB, EB, FB SeriesWith the world-renowned OMEGA until:2222222222222222222222222222222222 2222222222222222222222222222222222222222 222 Valid until:Integrated engineering COMPACT Series Rotary Blower Packages are deliv-ered complete with sound enclosure and integrated electrical equipment (optionally available as star-delta starter or variable speed control). All electrical equip-ment is sized according to required performance data and is wired and programmed for EMC compatibility as per applicable and safety Using numerous sensors, the internal SIGMA CONTROL 2 monitors and controls all parameters essential to reliable and effi cient Blower system oper-ation. Available remote monitoring and control further enhance Blower availability.

2 Versatile communication modules also enable SIGMA CONTROL 2 equipped Blower Packages to connect to master control sys-tems, such as the SIGMA AIR MANAGER, and / or other centralised control systems. Durability and effi ciency As with all KAESER products, COMPACT Series blowers are designed and constructed with maximum effi ciency, reliability and durability in mind. Together with their minimal maintenance and service require-ment, these versatile blowers ensure lowest possible life cycle costs. Components for Blower stationsNo matter whether for Blower air or compressed air, the same rule applies: The air system should be considered as a whole. No one understands this better than KAESER KOMPRESSOREN, which is why we offer specifi cally tailored air supply solutions for every need. Systems and equipment include Blower stations, master control systems, air treatment and piping which work seamlessly together to ensure maximum effi ciency and package conceptKAESER COMPACT blowers are designed to incur minimal operating and maintenance costs and to ensure maximum reliability.

3 Furthermore, blowers equipped with an integrated control system and star-delta starter, or frequency converter (for fl exible speed control), signifi cantly reduce the amount of work required for planning, installation, certifi cation, documentation and commissioning. COMPACT blowersImage: BBC OFC Series with SIGMA CONTROL 2controller and integrated frequency converterThe all-in-one systemIndustrial PC technologyThe SIGMA CONTROL 2 ensures effi cient Blower control and system monitoring. The large display and RFID reader provide easy communication and max-imum security. Multiple interfaces offer exceptional fl exibility, whilst the SD card slot makes updates quick and easy. blowersMeticulous design and manufactureDurable OMEGA Blower blockFor pressures up to 1000 mbar(g), discharge temp-eratures up to 160 C, wide control range with fre-quency controlled operation, Q rotor balancing for quieter operation, extended service life and minimal maintenance sized bearings Heavy-duty cylinder roller bearings completely ab-sorb the continuously changing radial gas-forces that are exerted on the cylinders.

4 As a result, they avoid the springing effect of self-aligning bearings and last up to ten times longer with the same sensors A wide range of sensors and switches for monitoring pressure, temperature, speed, oil level and fi lters ensures dependable Blower operation and enables remote monitoring and visualisation of operational machiningHigh precision 5f 21 quality straight-cut timing gears have minimal fl ank clearance and a play major role in contributing to the block s outstanding volumetric effi -ciency. As the straight-cut gearing is not subjected to continuously changing radial gas-forces, heavy duty cylinder roller bearings can be blowersVariable speed controlat its bestWide control rangeOptimised matching of the Blower block, drive motor and variable speed controller allows a wide control range to ensure maximum effi ciency in multi-unit operation without undershooting air demand ordelivering fl uctuating excess air control cabinetThe control cabinet houses only precisely matched electrical and electronic components from renowned German manufacturers.

5 When it comes to electro-magnetic compatibility (EMC), all cables are safely shielded where in control No matter whether the Blower system is equipped with star-delta starter or variable speed control, users can choose from numerous operating modes. This is particularly relevant if several units are to be incorpo-rated into a Blower system EMC certifi edThe electromagnetic compatibility (EMC) of thecomponents and the whole machine have been tested and approved in conformity with applicable speed controlEfficient KAESER variable speed controlSpecific power(kW/m /min)Air flow (m /min) display instrumentation Blowers equipped with a sound enclosure but no integrated electrical components feature a pressure gauge and fi lter maintenance indicator (pressureoperation) or fi lter differential pressure switch(vacuum operation).

6 A tele-thermometer withadjustable limit switch is also optionally availablefor block discharge temperature CONTROL 2 The SIGMA CONTROL 2 ensures effi cient Blower control and system monitoring. The large display and RFID reader provide easy communication and maximum security. Variable interfaces offer excellent fl exibility for data bus connection, whilst the SD card slot makes updates quick and COMPACT Blower package range from KAESERSIGMA AIR MANAGER advanced master control system can co-ordinate operation of 4, 8 or 16 blowers with maximum energy effi ciency and also enables seamless documentation of all operational : Station with DBC blowers and SIGMA AIR MANAGER in a water treatment aftercoolerHighly effi cient ACA aftercoolers specially developed by KAESER for operation with Rotary blowers.

7 With minimal pressure loss, they reduce Blower air temperature to a maximum of 10 C above ambient and require no cooling water. Electrical connection can be implemented directly in the Blower control absorption silencer min-imises process air pulsation down-stream from the Blower block. This results in low residual pulsation and therefore minimal sound transfer to downstream transmissionHighly effective automatic belt-tension-ing system for consistent transmission performance, V-belt safety grille, belt-tensioning mechanism also acts as a motor lifting device when chang-ing the CONTROL 2 with Blower -specifi c software, large display and RFID reader ensure effective com-munication and enhanced security. Outstanding fl exibility and easy con-nection to centralised control systems via variable interfaces, SD card reader for quick and easy updates as well as recording of operational blockRobust and durable, energy-effi cient OMEGA PROFILE rotors, wide control motorProprietary brand, premium effi ciency IE3 motor, three PTC thermistors as standard; variable speed drive models co-ordinated with OFC frequency con-verter.

8 Maintenance is fast and effi cient thanks to easy access central lubrica-tion points for motors with re-lubricata-ble motor bearings. Sound insulationThe system s Blower and motor cooling air is drawn in from outside the sound enclosure from the cooler ambient surroundings. Effective sound-proofi ng provided by thick-walled lining with dense foam and damping louvers over intake and exhaust openings. General designInlet silencer with fi lterBlower blockV-beltIE3 premium effi ciency motorDischarge silencerBlow-off valveUnloaded-start valve(option)Check valve(option)Expansion jointSound enclosure FanDetailed customer-specifi c planningThe KAESER ENERGY SAVING SYSTEM (KESS) provides compre-hensive analysis of your Blower air usage, enabling KAESER s experts to plan and design a system that is specially tailored to meet all of your Blower air needs.

9 Blower systems designed by KAESER ensure exceptional effi ciency and availa-bility for your application. Use this expertise to your advantage and let KAESER KOMPRESSOREN design your Blower air systemControl cabinetImage: ACA aftercoolerTechnical specifi cationsModell berdruckUnterdruckmax. Motor-nenn-leistungRohr-anschlussAbmessu ngen mit Schaltschrank und SchallhaubeB x T x Druck-diff erenzmax. Liefer-menge *max. Druckdiff erenzmax. Saug-verm genmbar ( )m /minmbar (vac)m /minkWDNmmkgBB 69 x 960 x 1200455BB 89 x 960 x 1200461CB 111 x 1150 x 1290583CB 131 x 1150 x 1290642DB 166 x 1150 x 1290802DB 236 x 1150 x 1290822EB 291 x 1600 x 17001561EB 421 x 1600 x 17001606FB 441 x 1920 x 19102326FB 621 x 1920 x 19102839FB 791 x 1920 x 20902541 ModelGauge pressureVacuumMax. rated motor power Pipe connectionDimensions with control cabinet and sound enclosureW x D x HMax.

10 MassMax. pressure diff erentialMax. fl ow rate *Max. pressure diff erentialMax. suction rate mbar (g)m /minmbar (vac)m viewRear viewLeft viewRight view3-D view BB 69/89 C Series Without control cabinetBB 69/89 C Series With control cabinetCB 111/131 C Series Without control cabinetCB 111/131 C Series With control cabinetDB 166/236 C Series Without control cabinetDB 166/236 C Series With control cabinet Front viewRear viewLeft viewRight view3-D view EB 291/421 C Series Without control cabinetEB 291/421 C Series With control cabinetFB 441/621 C Series Without control cabinet FB 441/621 C Series With control cabinetFB 791 C Series Without control cabinetFB 791 C Series With control cabinet 9609601150115011501150790121097015301110 1530170017001910191020902090160016001920 1920198019801420193516202230162022301200 12001290129012501290 OMEGA CONTROL BASICOMEGA CONTROL BASICKAESER


Related search queries