Transcription of RTU 1 - Trane
1 -RTU 1-RTU 2-RTU 3-RTU 4-RTU 5-RTU 6-RTU 7-RTU 8-RTU 9-RTU 10-RTU 11-RTU 12-RTU 13-RTU 14-RTU 15-RTU 16-RTU 17-RTU 18-RTU 19-RTU 20-RTU 21-RTU 22-RTU 23-RTU 24-RTU 25-RTU 26-RTU 27-RTU 28-RTU 29-RTU 30-RTU 31-RTU 32-RTU 33-RTU 34-RTU 35-RTU 36-RTU 37-RTU 38-RTU 39-RTU 40-RTU 41-RTU 42-RTU 43-RTU 44-RTU 45 Voyager Ton R-410 ATraneYC150-300 PACKAGED AIR CONDITIONERTYPEMARKMFRMODELHEATINGCOOLIN GEVAPORATOR AIR FLOWCOMPRESSORPOWER INPUTOUTPUTAFUECOMB.
2 FANFLAARI GROSSARI NETSEER EERCFMESPBHP FLA QTYRLA(TOTAL)LRA(TOTAL) FLAMAX CFM MIN CFM ESPFLAVOLTAGEPHASEHzFLATOTALMCATOTALMOCP TOTALRTU1 TRANEYC150E3L150, Btu/h122, A158, Btu/h110, A0 CFM0 A208 V360 A1616 MANUAL FRESH AIR DAMPERRTU2 TRANEYC150E4L150, Btu/h122, A158, Btu/h110, A0 CFM0 A480 V360 A1871 WELDED CURB, MANUAL FRESH AIR DAMPERRTU3 TRANEYC150E4L150, Btu/h122, A158, Btu/h110, A0 CFM0 A480 V360 A2166 SPRING ISOLATION CURB, MANUAL FRESH AIR DAMPERRTU4 TRANEYC150E3L150, Btu/h122, A158, Btu/h110.
3 A0 CFM0 A208 V360 A1884 ECONOMIZERRTU5 TRANEYC150E4L150, Btu/h122, A158, Btu/h110, A0 CFM0 A480 V360 A2139 ECONOMIZER, WELDED CURBRTU6 TRANEYC150E4L150, Btu/h122, A158, Btu/h110, A0 CFM0 A480 V360 A2434 ECONOMIZER, SPRING ISOLATION CURBRTU7 TRANEYC150E3L150, Btu/h122, A158, Btu/h110, A5000 CFM0 A208 V360 A2282100% MODULATING POWER EXHAUSTRTU8 TRANEYC150E4L150, Btu/h122, A158, Btu/h110, A5000 CFM0 A480 V360 A2537100% MODULATING POWER EXHAUST, WELDED CURBRTU9 TRANEYC150E4L150, Btu/h122, A158, Btu/h110, A5000 CFM0 A480 V360 A2832100% MODULATING POWER EXHAUST, SPRING ISOLATION CURBRTU10 TRANEYC180E3L250, Btu/h203, A188, Btu/h133, A0 CFM0 A208 V360 A2047 MANUAL FRESH AIR DAMPERRTU11 TRANEYC180E4L250, Btu/h203, A188, Btu/h133, A0 CFM0 A480 V360 A2417 WELDED CURB, MANUAL FRESH AIR DAMPERRTU12 TRANEYC180E4L250.
4 Btu/h203, A188, Btu/h133, A0 CFM0 A480 V360 A2717 SPRING ISOLATION CURB, MANUAL FRESH AIR DAMPERRTU13 TRANEYC180E3L250, Btu/h203, A188, Btu/h133, A0 CFM0 A208 V360 A2425 ECONOMIZERRTU14 TRANEYC180E4L250, Btu/h203, A188, Btu/h133, A0 CFM0 A480 V360 A2795 ECONOMIZER, WELDED CURBRTU15 TRANEYC180E4L250, Btu/h203, A188, Btu/h133, A0 CFM0 A480 V360 A3095 ECONOMIZER, SPRING ISOLATION CURBRTU16 TRANEYC180E3L250, Btu/h203, A188, Btu/h133, A6000 CFM0 A208 V360 A2947100% MODULATING POWER EXHAUSTRTU17 TRANEYC180E4L250, Btu/h203, A188, Btu/h133, A6000 CFM0 A480 V360 A3317100% MODULATING POWER EXHAUST, WELDED CURBRTU18 TRANEYC180E4L250, Btu/h203, A188, Btu/h133, A6000 CFM0 A480 V360 A3617100% MODULATING POWER EXHAUST, SPRING ISOLATION CURBRTU19 TRANEYC210E3L250, Btu/h203, A211, Btu/h157.
5 A0 CFM0 A208 V360 A2115 MANUAL FRESH AIR DAMPERRTU20 TRANEYC210E4L250, Btu/h203, A211, Btu/h157, A0 CFM0 A480 V360 A2485 WELDED CURB, MANUAL FRESH AIR DAMPERRTU21 TRANEYC210E4L250, Btu/h203, A211, Btu/h157, A0 CFM0 A480 V360 A2785 SPRING ISOLATION CURB, MANUAL FRESH AIR DAMPERRTU22 TRANEYC210E3L250, Btu/h203, A211, Btu/h157, A0 CFM0 A208 V360 A2493 ECONOMIZERRTU23 TRANEYC210E4L250, Btu/h203, A211, Btu/h157, A0 CFM0 A480 V360 A2863 ECONOMIZER, WELDED CURBRTU24 TRANEYC210E4L250, Btu/h203, A211, Btu/h157, A0 CFM0 A480 V360 A3163 ECONOMIZER, SPRING ISOLATION CURBRTU25 TRANEYC210E3L250, Btu/h203, A211, Btu/h157, A7000 CFM0 A208 V360 A3015100% MODULATING POWER EXHAUSTRTU26 TRANEYC210E4L250, Btu/h203, A211, Btu/h157, A7000 CFM0 A480 V360 A3385100% MODULATING POWER EXHAUST, WELDED CURBRTU27 TRANEYC210E4L250, Btu/h203, A211.
6 Btu/h157, A7000 CFM0 A480 V360 A3685100% MODULATING POWER EXHAUST, SPRING ISOLATION CURBRTU28 TRANEYC240E3L250, Btu/h203, A255, Btu/h188, A0 CFM0 A208 V360 Hz A A2175 MANUAL FRESH AIR DAMPERRTU29 TRANEYC240E4L250, Btu/h203, A255, Btu/h188, A0 CFM0 A480 V360 A2545 WELDED CURB, MANUAL FRESH AIR DAMPERRTU30 TRANEYC240E4L250, Btu/h203, A255, Btu/h188, A0 CFM0 A480 V360 A2845 SPRING ISOLATION CURB, MANUAL FRESH AIR DAMPERRTU31 TRANEYC240E3L250, Btu/h203, A255, Btu/h188, A0 CFM0 A208 V360 Hz A A2553 ECONOMIZERRTU32 TRANEYC240E4L250, Btu/h203, A255, Btu/h188, A0 CFM0 A480 V360 A2923 ECONOMIZER, WELDED CURBRTU33 TRANEYC240E4L250, Btu/h203, A255, Btu/h188, A0 CFM0 A480 V360 A3223 ECONOMIZER, SPRING ISOLATION CURBRTU34 TRANEYC240E3L250, Btu/h203, A255, Btu/h188.
7 A8000 CFM0 A208 V360 Hz A A3075100% MODULATING POWER EXHAUSTRTU35 TRANEYC240E4L250, Btu/h203, A255, Btu/h188, A8000 CFM0 A480 V360 A3445100% MODULATING POWER EXHAUST, WELDED CURBRTU36 TRANEYC240E4L250, Btu/h203, A255, Btu/h188, A8000 CFM0 A480 V360 A3745100% MODULATING POWER EXHAUST, SPRING ISOLATION CURBRTU37 TRANEYC300E3L250, Btu/h203, A290, Btu/h224, A0 CFM0 A208 V360 Hz A A2156 MANUAL FRESH AIR DAMPERRTU38 TRANEYC300E4L250, Btu/h203, A290, Btu/h224, A0 CFM0 A480 V360 A2526 WELDED CURB, MANUAL FRESH AIR DAMPERRTU39 TRANEYC300E4L250, Btu/h203, A290, Btu/h224, A0 CFM0 A480 V360 A2826 SPRING ISOLATION CURB, MANUAL FRESH AIR DAMPERRTU40 TRANEYC300E3L250, Btu/h203, A290, Btu/h224, A0 CFM0 A208 V360 Hz A A2534 ECONOMIZERRTU41 TRANEYC300E4L250, Btu/h203, A290.
8 Btu/h224, A0 CFM0 A480 V360 A2904 ECONOMIZER, WELDED CURBRTU42 TRANEYC300E4L250, Btu/h203, A290, Btu/h224, A0 CFM0 A480 V360 A3204 ECONOMIZER, SPRING ISOLATION CURBRTU43 TRANEYC300E3L250, Btu/h203, A290, Btu/h224, A10000 CFM0 A208 V360 Hz A A3056100% MODULATING POWER EXHAUSTRTU44 TRANEYC300E4L250, Btu/h203, A290, Btu/h224, A10000 CFM0 A480 V360 A3426100% MODULATING POWER EXHAUST, WELDED CURBRTU45 TRANEYC300E4L250, Btu/h203, A290, Btu/h224, A10000 CFM0 A480 V360 A3726100% MODULATING POWER EXHAUST, SPRING ISOLATION CURB 3/32" = 1'-0"1 Roof PlanINSTRUCTIONS FOR USING THE AC SCHEDULE:COPY (CTRL-C ) THE SCHEDULE FROM THIS SHEET VIEW AND PASTE (CTRL-V) IT INTO A 'SHEET' IN YOUR PROJECT FILE.
9 THE SCHEDULE IS PARAMETRIC AND WILL FILL ITSELF OUT BASED ON THE MECHANICAL EQUIPMENT (CATEGORY) ACTUALLY PLACED INYOUR PROJECT. THE SCHEDULE MAY NEED TO BE FILTERED TO SHOW ONLY SPECIFIC EQUIPMENT TYPES OR TYPE COLUMNS IN THE SCHEDULE ARE FILLED OUT BY THE OPTIONS SELECTED FOR EACH UNIT WITH THE EXCEPTION OF THE AIR FLOW CFM, THIS NUMBER IS DRIVEN BY THE CONNECTED FLOW OF DUCTWORK. THE EXTERNAL STATIC PRESSURE AND BHPSHOULD BE MANUALLY ADJUSTED AFTER ANALYSIS OF YOUR DUCT FOR USING THE MECHANICAL EQUIPMENT FAMILY:LOAD THE INDIVIDUAL FAMILY FILE (Voyager YC 12-25 Ton ) THAT HAS BEEN PROVIDED INTO YOUR PROJECT FILE.
10 CHANGE THE FAMILY TYPES AND VOLTAGES AS NEEDED. THE REMAINING OPTIONS ARE ADJUSTABLE VIA ELEMENT SPECIFY NO CURB, UN-CHECK THE "SHOWCURB" OPTION, FOR A WELDED CURB SELECT THE "SHOWCURB" OPTION, FOR A SPRING ISOLATION CURB SELECT BOTH "SHOWCURB" AND "ISOCURB"TO USE THE ECONOMIZER AND POWER EXHAUST OPTIONS ADJUST THE "1 NONE_2 ECON_3 PWREXH" PARAMETER TO ONE OF THE FOLLOWING CHOICES:1 - FOR NONE ( Trane OUTSIDE AIR HOOD ONLY)