Page 1 RXD Owner s ManualRXD Water SoftenerThis manual contains information on setting the controller and normaloperating maintenance required by the s ManualR4039 Water ConditioningRPage 2 RXD Owner s ManualUNPACKING INFORMATIONUnit is shipped with the necessary softening media already loaded in the mineral tank. Items packedseparately are located in the brine tank:A. Transformer 24 VoltB. By-passC. 9V Ni- Cad BatteryD. Owner's ManualE. WarrantyWARRANTY RECORD:INSTALLER RESPONSIBLE FOR ENTRIESCUSTOMER TO RETAINThis Water treatment equipment is warranted against defects in materials and workmanship according to thespecific terms of the warranty provided. To substantiate any warranty claims, retain the bill of sale, orpurchase contract, and the Water analysis report if SERIAL #_____DATE INSTALLED_____/_____/_____COMPENSATED Water HARDNESS_____ GPGTYPE OF SALT IN BRINE TANK _____DEALER NAME: _____ADDRESS: _____SPECEFICATIONSRXD 1000 RXD 1000 SRXD 1500 RXD 1500 DRXD 2000 Pressure range30 psi to 125 psiOperating Temperature40 F to 120 FElectrical24 V, 60 HzMax.

Page 4 RXD Owner’s Manual Installation and Start-Up Procedures 1. The water softener should be installed with the inlet, outlet and drain connections made in accordance

Tags:

  Softener, Water, Water softener, Rxd water softener

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of RXD Water Softener - Rayne Quality Water

1 Page 1 RXD Owner s ManualRXD Water SoftenerThis manual contains information on setting the controller and normaloperating maintenance required by the s ManualR4039 Water ConditioningRPage 2 RXD Owner s ManualUNPACKING INFORMATIONUnit is shipped with the necessary softening media already loaded in the mineral tank. Items packedseparately are located in the brine tank:A. Transformer 24 VoltB. By-passC. 9V Ni- Cad BatteryD. Owner's ManualE. WarrantyWARRANTY RECORD:INSTALLER RESPONSIBLE FOR ENTRIESCUSTOMER TO RETAINThis Water treatment equipment is warranted against defects in materials and workmanship according to thespecific terms of the warranty provided. To substantiate any warranty claims, retain the bill of sale, orpurchase contract, and the Water analysis report if SERIAL #_____DATE INSTALLED_____/_____/_____COMPENSATED Water HARDNESS_____ GPGTYPE OF SALT IN BRINE TANK _____DEALER NAME: _____ADDRESS: _____SPECEFICATIONSRXD 1000 RXD 1000 SRXD 1500 RXD 1500 DRXD 2000 Pressure range30 psi to 125 psiOperating Temperature40 F to 120 FElectrical24 V, 60 HzMax.

2 Hardness range (gpg)6070100 Service Flow Capacity (grains) Minimum - EfficiencySetting20,00030,00040,000 Softening Capacity (grains) Maximum30,00045,00060,000 Salt Dosage (lbs.) Minimum - Efficiency Setting6912 Salt Dosage (lbs.) Maximum1522 1/230 Clear Water of Iron Removal Capacity (ppm) *556 Brine Valve SystemNoryl Safety Float*NOTE: MUST BE SET AT MAXIMUM SALT FOR IRON REMOVAL SALT-Use evaporated salt such as solar, pellet, nugget, button, crystal, or tabs. Rock salt is notrecommended because it commonly contains silt and sand which can hamper the operation of theequipment. DO NOT use granulated types. Block types labeled for Water Softener use are acceptable,however, DO NOT drop into brine tank or stack more than two 3 RXD Owner s ManualINTRODUCTIONYour new Rayne automatic Water Softener will contribute to better and longer service from all the Water usingappliances in your home.

3 You'll soon appreciate the many savings and personal benefits that soft DETAILSOWNER'S RESPONSIBILITYA. Maintain a supply of proper type salt in the brine tank. (See SPECIFICATIONS)B. Occasionally inspect drain lines for possible restriction, clogging, or Occasionally cleaning of the softening resin is recommended. Specialty chemicals are available to cleanand maintain Water Softener efficiency. When purchasing, look for the active ingredient SODIUMHYDROSULFITE on the label of the cleaning agent .D. Clean brine tank periodically. (once a year is recommended)E. Protect the system from freezing - If system is used in a summer home, system should be drained downand protected against Water outside faucetsContinuous power supplyBrine tank overflow 1/2 diameterminimum size (gravity flow)Drain line 1/2 diameterminimum sizeSanitary drain or laundrytubs are not make connectionto the drain.

4 An air gapmust be Tank InstallationCheck Valve (optional) Water inlet30 psi minimum pressure3/4 minimum pipe sizeSoftened Water outletGrounding strap to maintain house groundingPage 4 RXD Owner s ManualInstallation and Start-Up Procedures1. The Water Softener should be installed with the inlet, outlet and drain connections made in accordancewith the manufacturers recommendations and to meet applicable plumbing Plug the valve transformer into an approved power source. Once the valve is powered, it may cycle itselfto return to In normal operation the Time of Day, Volume Remaining Displays will alternate being viewed. Set theTime of Day Display by depressing the Up or Down Set Button, to the correct time. (See Fig. 1) Note:Time of Day must be set correctly to either or (See Fig. 1).4. The value displayed in the Volume Remaining Display will be the volume of Water (In gallons) remainingprior to regeneration, including any reserve capacity.

5 Open a soft Water tap. As Water flows through thesoftener, the number displayed will decrease. Close the tap after 3 - 5 gallons of Water Cycle the valve to the backwash position by depressing the Extra Cycle Button for 5 seconds, and allowwater to run to drain for 3 to 4 minutes. Using the extra cycle button continue to step the valve throughthe other regeneration cycles checking for Brine Draw, Rapid Rinse, and Brine tank fill. Allow the valveto return to service automatically from brine tank Make sure the salt dosage is set as recommended by the Fill the brine tank with The RXD Valve is equipped with a 9 Volt Alkaline Battery. It is recommended this battery be changedonce a year. Daylight Savings Time is a good time to do so. The battery is located below theelectronics, inside the front cover. In the event of a power outage, the battery will maintain currentsystem information (Time of Day, Volume Remaining, etc.)

6 For approximately 24 hours at maximumbattery capacity. This backup time will vary, depending on flow meter usage during the power outage. Ifthe power interruption exceeds the capacity of the battery backup, the normal operating display(s)information will be For the valve to resume normal operation, it will be necessary to reset only the Time of Day can be done by depressing either the Up or Down Arrow Buttons. The valve will automaticallyinitiate a regeneration cycle 5 minutes after power re-application. All valve programming however, isstored in special non-volatile memory that can be retained for years without During cold weather it is recommended that the installer warm the valve up to room temperature 5 RXD Owner s ManualIn ServiceTimeReserveMeterRegenVolumeRemain ingProgram2:00 SETP!!!!!EXTRACYCLEPROGRAMPRESS OR AS NEEDED.!!!!!EXTRA CYCLE-TO SET TIME-PRESS ONCEFOR AND HOLD5 SECONDS IndicatorProgram IndicatorUp Set ButtonDown Set ButtonProgram ButtonExtra Cycle ButtonOption Setting Level #1 - Installer UP and Down Arrows to Set Time of DaySetting up the valve during installation requires access to the first level of option Option Level #1 Depress for the Program Button for 5 seconds.

7 The Program Arrow will turn on and the first display viewedis used to set the Inlet Water Water Hardness (H)The unit of measure used for this setting is grains. This option setting is identified by the letter H in thefirst :25 grains[H - - - - 25]The UP and DOWN Set Buttons will adjust this Regeneration TimeDepress the Program Button. The next display viewed is the option for Regeneration Time. It isidentified by a non- flashing colon between two sets of :2 o clock regeneration time[ 2:00 ] ( Indicator On)The UP and DOWN Set Buttons will adjust this This Option Setting LevelPush the Program Button to return to Time to Day / Gallons Notes1. Control Calculations - With Delayed Regeneration Valves, the control is designed to automaticallycalculate the number of gallons between regenerations and set the reserve capacity based on daily waterusage.

8 There is no need to program either of these settings. The System capacity Option Setting shouldbe set to the resin bed manufacturers capacity recommendations for a given amount of salt to be usedduring 6 RXD Owner s ManualWater Flow DiagramsPage 7 RXD Owner s ManualPage 8 RXD Owner s ManualWater Softener AssemblyItem # RXD1000 RXD1500 RXD1500-D RXD2000 RXD1000-S Description1 RXD Controller - Specify Model2 Bypass , plastic 1"3ST104010 x 40ST125212 x 52ST103510 x 35 Mineral Tank4RF01010n/aTank Base5 High Flow 1" Distributor - Specify Model1 cf2 cf1 x 40CK1047 Almond10 x 47SS1047 Stainless Steel10 x 47CK1252 Almond12 x 52n/aJacket - Almond8SS0010RF01212n/aCollar - Black9n/an/an/an/aCK1111 Cabinet10n/an/an/an/aCK0011 Cabinet Deck506610360049RF0030RF00015A1020-5 High Capacity Resin, C-249RF00011ST104710 x 47 611034259678 Page 9 RXD Owner s ManualBrine Tank Assembly123456778 Item # RXD1000 RXD1500 RXD1500-D RXD2000 RXD1000-S Description1C10772BR C10771 BRCK1000 SComplete Brine Tank Assembly2B08802BR15 x 17, Black B08801BR15 X 17, AlmondCK111111 x11, AlmondBrine Tank3CK000111 x11, BlackBrine Tank Lid4 Brine Line5 Overflow fitting6 Brine Well7 Brine Well Lid8 Brine Valve Assembly2310C10771 BRA05300 BRA14120 BRB08801BR15 x 17, AlmondA10171BR15 x 17 BlackA11510 BRA13940 BRPage 10 RXD Owner s ManualControl Valve AssemblyPage 11 RXD Owner s ManualDownflow Control ValveItem No.

9 Description1 ..1 ..18815 ..Valve Body, 5000, 1 " ..1 ..18264 ..Spacer, End3 ..4 ..14241 ..Spacer4 ..5 ..13242 ..Seal5 ..1 ..18265 ..Piston, Downflow6 ..1 ..14309 ..Retainer, Piston Rod7 ..1 ..18268 ..End Plug Assembly8 ..3 ..18261 ..Screw, Hex Washer Head, 10-24 x 13/169 ..1 ..18267 ..Piston Rod10 ..1 ..17978 ..Brine Valve Stem11 ..1 ..18755 ..Seat, Brine Valve12 ..1 ..13167 ..Spacer, Brine Valve13 ..1 ..12550 ..Quad Ring, -00914 ..2 ..13302 ..0 Ring, -01415 ..1 ..13165 ..Cap, Brine Valve16 ..1 ..11973 ..Spring, Brine Valve17 ..1 ..16098 ..Washer, Plain, Nylon18 ..1 ..11981-01 ..Retaining Ring19 ..1 ..11183 ..0 Ring, -01720 ..1 ..Flow Washer (specify size)21 ..1 ..11385-01 ..Flow Control Housing, Plastic22 ..1 ..18312 ..Retainer, Drain23 ..1 ..13304 ..0 Ring, -12124.

10 1 ..18303 ..0 Ring, -33625 ..2 ..10141 ..0 Ring, -01026 ..1 ..18276 ..Plug, Injector27 ..2 ..13771 ..0 Ring, -01228 ..1 ..18275-X ..Injector Throat (specify size) 000, 00, 0, 1, 2, 329 ..1 ..18274-X ..Injector Nozzle (specify size) 000, 00, 0, 1, 2, 330 ..1 ..18273 ..Vortex Generator31 ..1 ..18271 ..Screen Injector32 ..1 ..18301 ..Seal, Injector33 ..1 ..18277 ..Cap, Injector, Softener34 ..2 ..18262 ..Screw, Hex Washer Head, 10-24 x 135 ..1 ..12977 ..0 Ring, -01536 ..1 ..13245 ..Retainer, BLFC Button37 ..1 ..Flow Washer (specify size)38 ..1 ..13244 ..Adapter, BLFC39 ..1 ..13308 ..Hose Barb, Black, 1/2 x 112 Straight1 ..12338 ..Hose Barb, Black, 1/2 x 1/2 900 Elbow40 ..1 ..18280 ..Top Collector, 1 X .011, GrayPage 12 RXD Owner s ManualControl Drive Assembly162394875 Item No. QuantityPart No.