(S) LPRFM-5R J30-05377C INSTALLATION INSTRUCTIONS …

(S) LPRFM-5RJ30-05377 CINSTALLER'S RESPONSIBILITYI nstaller Please Note: This equipment has been test fired and inspected. It has beenshipped free from defects from our factory. However, shipment and installationproblems such as loose wires, leaks, or loose fasteners may occur. It is the installer'sresponsibility to inspect and correct any problem that may be INSTRUCTIONSI nspect shipment immediately whenreceived to determine if any damage hasoccurred to the unit during shipment. Afterthe unit has been uncrated, check for anyvisible damage to the unit. If any damageis found, the consignee should sign the billof lading indicating such damage andimmediately file claim for damage with thetransportation PRODUCTS260 NORTH ELM ST.

Installation must be made in accordance with local codes, or in absence of local codes, with ANSI Standard Z223.1-2002. (N.F.P.A. No. 54) National Fuel Gas Code, or the latest edition of. All of the ANSI and NFPA Standards referred to in these installation instructions are those that were applicable at the time the design of this appliance was ...

Tags:

  Design, Installation, Instructions, Installation instructions

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of (S) LPRFM-5R J30-05377C INSTALLATION INSTRUCTIONS …

1 (S) LPRFM-5RJ30-05377 CINSTALLER'S RESPONSIBILITYI nstaller Please Note: This equipment has been test fired and inspected. It has beenshipped free from defects from our factory. However, shipment and installationproblems such as loose wires, leaks, or loose fasteners may occur. It is the installer'sresponsibility to inspect and correct any problem that may be INSTRUCTIONSI nspect shipment immediately whenreceived to determine if any damage hasoccurred to the unit during shipment. Afterthe unit has been uncrated, check for anyvisible damage to the unit. If any damageis found, the consignee should sign the billof lading indicating such damage andimmediately file claim for damage with thetransportation PRODUCTS260 NORTH ELM ST.

2 , WESTFIELD, MA 01085 TEL: (413) 564-5540 FAX: (413) 562-5311 MODELS: RF-30, 45, 60, 75, 90 Model : READ THIS MANUAL AND ALL LABELS ATTACHED TO THE UNIT CAREFULLY BEFOREATTEMPTING TO INSTALL, OPERATE OR SERVICE THESE UNITS! CHECK UNIT DATA PLATE FOR TYPE OF GAS ANDELECTRICAL SPECIFICATIONS AND MAKE CERTAIN THAT THESE AGREE WITH THOSE AT THE POINT OF THE UNIT MODEL AND SERIAL No.(s) IN THE SPACE PROVIDED. RETAIN FOR FUTURE INSTRUCTIONS AND PARTS LISTTUBULAR GAS FIRED PROPELLER UNIT HEATERS FOR RESIDENTIAL INSTALLATIONS 09/04 Please utilize this toll free number to contact your localrepresentative YOUR SAFETYWHAT TO DO IF YOU SMELL GASDo not try to light any not touch any electrical switch; donot use any phone in your call your gas supplierfrom a neighbor s phone.

3 Follow thegas supplier s you cannot reach your gas supplier,call your fire FOR USE IN CALIFORNIA Install, operate, and maintain unit in accordance with the manufacturer'sinstructions to avoid exposure to fuel substances, or substances from incomplete combustion,which can cause death or serious illness. The state of California has determined that thesesubstances may cause cancer, birth defects, or other reproductive harm. Improper INSTALLATION , adjustment, alteration, service, or maintenance cancause property damage, injury, or death. Read the INSTALLATION , operating, andmaintenance instruction thoroughly before installing or servicing this YOUR SAFETYDo not store or use gasoline or other flammable vapors and liquids in the vicinity of this orany other OF CONTENTSThe following terms are used throughout this manual, in addition to the CSA requirements to bring attention to thepresence of potential hazards, or to important information concerning the product: Indicates an imminently hazardoussituation which, if not avoided, will result indeath, serious injury, or substantial propertydamage.

4 Indicates an imminently hazard-ous situation which, if not avoided, could resultin death, serious injury, or substantial propertydamage. Indicates an imminently hazardoussituation which, if not avoided, may result in minorinjury or property : Used to notify of special INSTRUCTIONS oninstallation, operation, or maintenance which areimportant to equipment but not related to Description .. 2 Performance & Specification Data .. 4 GENERAL SAFETY INFORMATIONI nstallation Codes .. 2, 3 Special Precautions .. 2, 3 INSTALLATIONL ocating Units .. 5, 6 Combustion Air .. 5, 6 Proper Clearances .. 5, 6 Suspension of Units .. 5, 6 Gas Supply Piping.

5 7, 8 ELECTRICAL CONNECTIONS .. 9, 10, 11, 12 VENTING .. 13, 14, 15, 16, 17 OPERATIONE xplanation of Controls and Operation .. 18 Main Burner Orifice Schedule .. 19 Adjustments .. 19 High Altitude Operation .. 19, 20 MAINTENANCES ervicing & Cleaning .. 20 TROUBLESHOOTING GUIDE .. 21, 22, 23, 24 IDENTIFICATION OF PARTS .. 25, 26 WARRANTY .. 27 INSPECTION SHEET .. 28 See Identification of Parts throughout this Residential Tubular Gas Fired Unit Heater is afactory assembled, power vented, low static pressuretype propeller fan unit heater designed to be suspendedwithin the space to be heated. THESE HEATERS ARENOT TO BE CONNECTED TO DUCTWORK.

6 TheseTubular Unit Heaters are design certified underFigure 1 - Tubular 30 thru 90 Propeller Unit HeatersNOTICE: It is the equipment owners responsibility to provide any scaffolding or other apparatus required toperform emergency service or annual/periodic maintenance to this . (2nd ed.) Unit Heaters for ResidentialInstallation . The designs are certified by CSAI nternational as providing a minimum of 80% thermalefficiency, and approved for use in California. Do notalter these units in any way. If you have any questionsafter reading this manual, contact the SAFETY INFORMATION Failure to comply with the generalsafety information may result in extensiveproperty damage, severe personal injury, ordeath.

7 This product must be installed bya licensed plumber or gas fitter when installedwithin the Commonwealth of must be made in accordance with localcodes, or in absence of local codes, with ANSIS tandard ( No. 54) National FuelGas Code, or the latest edition of. All of the ANSI andNFPA Standards referred to in these installationinstructions are those that were applicable at the timethe design of this appliance was certified. The ANSIS tandards are available from the American GasAssociation, 1515 Wilson Boulevard, Arlington, Virginia22209. The NFPA Standards are available from theNational Fire Protection Association, Batterymarch Park,Quincy, MA installed in Canada, the INSTALLATION must conform withlocal building codes, or in the absence of local buildingcodes, with " INSTALLATION Codes for NaturalGas Burning Appliances and Equipment" or " INSTALLATION Codes for Propane Gas Burning Appliancesand Equipment.

8 " These unit heaters have been designedand certified to comply with CGA Do not alter the unit heater in anyway or damage to the unit and/or severe personalinjury or death may occur!Disconnect all power and gassupplies before installing or servicing the the power disconnect is out of sight, lock it inthe open position and tag it to prevent unexpectedapplication of power. Failure to do so could resultin fatal electric shock, or severe personal injury. Insure that all power sources conformto the requirements of the unit heater, or damage tothe unit will result!Follow INSTALLATION INSTRUCTIONS CAREFULLY to avoidcreating unsafe conditions. All wiring should be doneand checked by a qualified electrician, using copper wireonly.

9 All gas connections should be made and leak-tested by a suitably qualified individual, per instructionsin this manual. Also follow procedures listed on "GasEquipment Start-Up Sheet" located in this only the fuel for which the heater is designed (seerating plate). Using LP gas in a heater that requiresnatural gas, or vice versa, will create risk of gas leaks,carbon monoxide poisoning, and explosion. Do not attempt to convert theheater for use with a fuel other than the oneintended. Such conversion is dangerous, as itwill create the risks previously certain that the power source conforms to theelectrical requirements of the heater.

10 Do not depend upon a thermostator other switch as sole means of disconnectingpower when installing or servicing heater. Alwaysdisconnect power at main circuit breaker asdescribed above. Failure to do so could result infatal electric attention must be given to any groundinginformation pertaining to this heater. To prevent the riskof electrocution, the heater must be securely andadequately grounded. This should be accomplished byconnecting a ground conductor between the service paneland the heater. To ensure a proper ground, the groundingmeans must be tested by a qualified not insert fingers or foreign objects into heater or itsair moving device.