SA100 & SA100 -R Digital Readout DisplayNEWALL MEASUREMENT SYSTEMS LTDNC ontentsSA100 Linear & RotaryNewall Measurement Systems1 ContentsSA100 Digital - Linear & Technical a Floating SA100 Digital - - Axis Displayed - - Head Fail LOAD - Reference ERR - Linear Error & SFT - Scale SA100 Digital - Menu - Automatic - Axis Displayed - - Head Fail LOAD - Reference ERR - Angular Error G RATIO - Gear Ratio ANGLE - Angle Display DISP - Display RADIUS - Table Radius CPR - Counts Per SA100 Digital - Linear & Rotary / Appendix Of Auxillary Reference TECHNICAL sheet metalDimensions:Height72mm( ")Width144mm( ")Depth70mm( ") ( )Operating Voltage:12 - 27 VDC 10%Supply Voltage Fluctuation:Within operating voltage rangeMaximum Power Consumption:6 wattsOperating Temperature:0 to 45oCStorage Temperature:-20 to 60oCInputs:Single channel quadrature Input Configuration:(See DIP switches on rear of DRO)Differential Encoder Input (A, /A, B, /B, RM, /RM)Single Ended Encoder Input (A, B, RM)Environmental Conditions:Indoor use, IP20 Pollution degree 2 in accordance with IEC664 Relative Humidity: Maximum 80% for temperatures up to 31oCDecreasing linearly to 33% at 45oCEMC Compliance:BS EN 50081-2 Electromagnetic CompatibilityGeneric Emission Standard - Industrial EnvironmentBS EN 50082-2 Electromagnetic CompatibilityGeneric Immunity Standard - Indust

NOTES Introduction SA100 Linear & Rotary 5 Newall Measurement Systems 4.0 INTRODUCTION The SA100 range of digital readouts, DRO, offers the very best in functional versatility backed by Newall's famous robustness and quality guarantee. Two versions are available:

Tags:

  Display, Digital, Sa100, Readout, Sa100 amp sa100 r digital readout display, Newall

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SA100 & SA100-R Digital Readout Display - Newall

1 SA100 & SA100 -R Digital Readout DisplayNEWALL MEASUREMENT SYSTEMS LTDNC ontentsSA100 Linear & RotaryNewall Measurement Systems1 ContentsSA100 Digital - Linear & Technical a Floating SA100 Digital - - Axis Displayed - - Head Fail LOAD - Reference ERR - Linear Error & SFT - Scale SA100 Digital - Menu - Automatic - Axis Displayed - - Head Fail LOAD - Reference ERR - Angular Error G RATIO - Gear Ratio ANGLE - Angle Display DISP - Display RADIUS - Table Radius CPR - Counts Per SA100 Digital - Linear & Rotary / Appendix Of Auxillary Reference TECHNICAL sheet metalDimensions:Height72mm( ")Width144mm( ")Depth70mm( ") ( )Operating Voltage:12 - 27 VDC 10%Supply Voltage Fluctuation:Within operating voltage rangeMaximum Power Consumption:6 wattsOperating Temperature:0 to 45oCStorage Temperature:-20 to 60oCInputs:Single channel quadrature Input Configuration:(See DIP switches on rear of DRO)Differential Encoder Input (A, /A, B, /B, RM, /RM)Single Ended Encoder Input (A, B, RM)Environmental Conditions:Indoor use, IP20 Pollution degree 2 in accordance with IEC664 Relative Humidity: Maximum 80% for temperatures up to 31oCDecreasing linearly to 33% at 45oCEMC Compliance:BS EN 50081-2 Electromagnetic CompatibilityGeneric Emission Standard - Industrial EnvironmentBS EN 50082-2 Electromagnetic CompatibilityGeneric Immunity Standard - Industrial EnvironmentNEWALL MEASUREMENT SYSTEMS LIMITED RESERVES THE RIGHT TO CHANGE THE SPECIFICATION WITHOUT NOTICET echnical SpecificationSA100 Linear & RotaryNewall Measurement Systems2 ONONC ertificate No FM36096 CONNECTIONNOTESNote.

2 For implementationof the remote Index facilityand Auxiliary options seeSection number DSA11000denotes the unit to be forlinear measurement number DSA11000-Rdenotes the unit to be forRotary measurement optional, external, powersupply unit is contact yourdistributor for details. ConnectionSA100 Linear & RotaryNewall Measurement CONNECTIONINPUTSA uxiliary Input15-way D EncoderInput9-way D Power Inlet12-27 Vdc 10%Encoder Type DIPS witchesAll On for Differential I/PEquipotential TerminalFor grounding to machineRating LabelCable Retaining Clamp ModelNumber Serial NumberAuxiliary Input (15-way D)Pin +5V DC8+5V DC90V10 Reserved11 Reserved12 Remote Index13 Reserved14 Reserved150 VEncoder Input (9-way D)Pin No. Function1 N/C (or 0V)2 Channel A3 Channel /A4 Channel B5 Channel /B60V7+5V8 Channel RM9 Channel /RMWARNING! DO NOT CONNECT THE UNIT DIRECTLY TO THE MAINSPOWER S/C SPRING WASHER26M4 FLAT WASHER25 SPACE WASHER24M4X12 CAP HD SCREW23 KNOB22 BRACKET21 BRACKET1 ITEMDESCRIPTIONQTYNOTESI nstallation SA100 Linear & RotaryNewall Measurement INSTALLATIOND esktop or support mounting armPanel Mounting376124761234567An opional installation kit allowing for either desk, or panel mounting is available.

3 (Part Number: DSAKIT)5 NOTESI ntroductionSA100 Linear & RotaryNewall Measurement INTRODUCTIONThe SA100range of Digital readouts, DRO, offers the very best in functional versatility backed by Newall 's famous robustness and quality versions are available:The SA100 Digitalfor applications where a linear displacement is to be SA100 -R Digital . This DRO offers a range of functions specifically targeted at rotary applications, be they measured by a shaft encoder or a radius ensure that you have the correct SA100 Digital model for your manual covers both versions of the SA100 . Please refer to the relevant sectionfor details of keypads on the SA100 and SA100 -Rarespecifically targeted ateither Linear or Rotary [angle]keySee configuration of ANGLEin Set-Up fordetailed information onRollover and continuousoperating Continuous mode= Radial modeSee over page for detailedinstructions on using thereference NORMAL OPERATIONSA1001. Pressing [abs/inc]key toggles between absolute and incremental mode.

4 LED's on the [abs/inc]key indicate current operating Pressing [in/mm]key toggles between inch and millimetre mode. LED's on the[in/mm]key indicate current operating Pressing this key zeroes the current absolute or incremental position, as indicated by the LED's on the [abs/inc] find a scale reference marker press the[0]key and, whilst held, press the[abs/inc] Pressing[abs/inc]key toggles between absolute and incremental mode. LED's on the [abs/inc]key indicate current operating A)Rollover ( 360o)Pressing the [angle]key toggles between positive and negative arcs. The LED's on the[angle]key indicates the current operating angle = ( Negative angle + 360o) +270o -90oB)Continuous count ( )Pressing the [angle]key toggles between the continuous measured count and the radial, arc, position. the continuous measured position minus the number of whole 360orotations. The LED's on the [angle]key indicates the current operating measured angle = angle = 973o- (2 x 360o) = 253o3.

5 Pressing this key zeroes the current absolute or incremental position, as indicated by the LED's on the [abs/inc] ReferenceTo find a scale reference marker depress the [0o] key and, whilst held, press the [abs/inc] OperationSA100 Linear & RotaryNewall Measurement Systems60absinc+0absinc+NOTES! reference functionworks the same way onboth the SA100 and SA100 -R the SA100 -R the[angle] key replaces the[in/mm] :Mark the datum position onthe machine bed to allowfor this position to be locat-ed :For best accuracy, alwaysreference by approachingthe index marker in thesame REFERENCE OPERATIONNote:This function only works with encoders that provide an index marker output signal. However an externally generated reference ( a limit switch) can also be used. Please refer to APPENDIX A for more feature allows for any given axes to be referenced to a datum position. Theindex marker pulse, from the encoder, is used to generate a signal that informs theDRO that the reader head has reached its datum position.

6 Index pulses generallyappear in one of two forms depending on the type of encoder connected. These caneither be periodic, say 20mm, or single action. Generally, when a scale has a singleaction index marker this is located at the centre of Enter Reference mode using the [0]+ [abs/inc] key The Display will show' REF'. The SA100will continue to show this until a reference marker is foundorthe referencing operation is aborted using the[in/mm]key. A) For Periodic Index pulsesPosition the encoder such that it lies between the datum index marker and the nextindex marker position. (Say, within +/-15mm for a 20mm index period). the axis towards the datum index position. Once the index marker has been triggered the axis will start to count. The axis positionis now referenced to that datum position. Both absolute and incremental axis values will be loaded with the value assigned to REF LOAD during Set-Up. This value may be positive, negative or ) For Single Shot Index marker3.

7 Move the axis towards the datum index position. Once the index pulse has been triggered the axis will start to count. The axis position is now referenced to that datum position. Both absolute and incremental axis values will be loaded with the value assigned to REF LOAD during Set-Up. This value may be positive, negative or 1:The axis will start to count from the value defined in Set-Up for 'REF LOAD'.Note 2: Refer to the encoder manual for specification information relating to its Index marker(s).Note: 3If the operation is aborted the axis position (absolute or incremental) will be zeroed. any previous position information will be Operation SA100 Linear & RotaryNewall Measurement Systems7 NOTES! facility is only used toenter numerical values during a digit position whichis currently blank and proceeds a numeric digitcan have a'-', minus, signinserted by use of the[abs/inc] keyEditing A Floating Point ValueSA100 Linear & RotaryNewall Measurement EDITING A FLOATING POINT VALUEOn entry into a parameter edit mode (by the [abs/inc]key) the existing parametervalue is displayed.

8 A cursor is shown either as a flashing'_',(underscore), if the digitposition is blank or as a flashing version of the digit at the current three SA100keys are used to edit a value as follows:SA100SA100-RDescription[0][0o]Us ed as "ENTER" when the required value has been keyed in.[abs/inc][abs/inc]Used to scroll the digit at the current position through the values: -, 0, [in/mm][angle]Used to move the cursor through the numeric digitsto be ' that the[in/mm]keys LED's are in thedesired mode prior to entering Set-Up. The unit ofmeasurement (inch or mm)used during Set-Up isdefined by the current operating Display mode. SET-UP MODE SA100 (Linear) Newall Measurement SET-UP MODE SA100 (Linear)Entry into Set-Up mode is achieved by holding down the[abs/inc]key during nor-mal operation and then pressing the [in/mm] key in SET-UPmode the following menu items are accessible:To move through the available Set-Up options press the[in/mm] the[0]key to save changes and exit Set-UpARAxis resolutionToggle through available options using the[abs/inc]key DRDisplay resolution (mm)Toggle through available options using[abs/inc]keyDIRD irection (0 or 1)Toggle using [abs/inc]key to change sense of directionFENFail Enable (ON or OFF)Toggle using [abs/inc]key (OFF = Ignore, ON = Sensor faildetected)REF LOADAxis Load value used during referencing [abs/inc]key allows ERRL inear Error Comp ( to ).

9 Pressing [abs/inc]key allows Factor ( to ).Pressing [abs/inc]key allows Factor Type (0 or 1)Toggle using[abs/inc]key (0 = Multiply, 1 = Divide)When the parameters have been configured, return to the SET-UPmenu item andpress [0]to return to normal operation mode. SA100 Digital LINEAR Digital status of the[in/mm]key on entry in to Set-Updetermines the mode ofdata entry, Inch or - Axis Resolution / DR - Displayed ResolutionSA100 (Linear) Newall Measurement AR - AXIS RESOLUTIONAxis resolution is the distance moved between successive encoder output :A 5-micron resolution would be derived from an encoder having a 20-micron a times four multiplier will be :From Set-Up select AR'.Use the [abs/inc] key to toggle through the available axis microns5 DR - DISPLAYED RESOLUTIONThe displayed resolution does not have to coincide with the selected Axis can not however be selected to be of a higher resolution than that defined forAxis :From Set-Up select 'DR'.

10 Use the [abs/inc]key to toggle through the available Display :If the Axis Resolution is set to 1 the [abs/inc]key to toggles through , , and , the displayed resolution can be selected to be 1, 2, 5 or 10 ! check encoder specification for informationon the synchronisation ofthe index marker pulse. Ifthe encoder is capable ofgenerating the illegal condition (A low, B low andRM high) then the automat-ic head failure detectionshould be TURNED OFF.! reference function canstill be implemented evenwith the head fail detectcapability turned OFFDIR - Direction / FEN - Head Fail DetectionSA100 (Linear) Newall Measurement DIR - DIRECTIOND irection allows the operator to change the positive direction of travel of the :From Set-Up select 'DIR'.Use the [abs/inc]key to toggle the setting value between 0 and :If the current setting is 0 and the travel is positive from right to left then changingthe setting to 1will reverse the direction to measure positive from left to FEN - HEAD FAIL DETECTIONThe SA100has the facility to detect if the attached encoder has become discon-nected, sustained severe cable damage or with some encoders, electronic of OperationThe detection mechanism monitors the incoming signals from the encoder to lookfor an illegal combination of input levels.