Example: bachelor of science

Safe and reliable cable solutions for the world’s …

safe and reliable cable solutions for the world's nuclear industry Nuclear viability . Recent years have seen a (GCR), a Liquid Metal renaissance of nuclear power Fast Reactor (LMFR), worldwide. There are some or Accelerator-Driven System 435 nuclear power reactors (ADS), you are also looking in operation which account for to improve performance, 14% of the world's electricity, while lowering construction and 30% within the European and operating costs. Union. New reactors are being built in China, India, That is where custom-designed, Japan, the Russian Federation, nuclear-qualified cables play South Korea, France, Finland, an important role by providing Slovakia, Romania and Bulgaria.

…requires safe and reliable cables Nexans nuclear cables help assure a clean source of economical energy for coming generations. From basic power to complex

Tags:

  Solutions, Safe, Cable, Reliable, Safe and reliable cable solutions for the, Safe and reliable

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Safe and reliable cable solutions for the world’s …

1 safe and reliable cable solutions for the world's nuclear industry Nuclear viability . Recent years have seen a (GCR), a Liquid Metal renaissance of nuclear power Fast Reactor (LMFR), worldwide. There are some or Accelerator-Driven System 435 nuclear power reactors (ADS), you are also looking in operation which account for to improve performance, 14% of the world's electricity, while lowering construction and 30% within the European and operating costs. Union. New reactors are being built in China, India, That is where custom-designed, Japan, the Russian Federation, nuclear-qualified cables play South Korea, France, Finland, an important role by providing Slovakia, Romania and Bulgaria.

2 Long-term viability, and assuring fail- safe operation Aside from obvious economic indefinitely. benefits, nuclear energy can help curb global pollution What you expect from and greenhouse gases, and a cable producer: reduce dependency on fossil w ide range of state- fuels. However, to win wide of-the art cables for public acceptance, nuclear existing and new projects power has to be perceived as being absolutely safe , o ptimized operation, under all conditions and maintenance, and power far into the future. plant life management (PLIM). p roven solutions adapted As a nuclear power plant to national standards authority or operator, and requirements you not only expect new plants to achieve new levels of safety p erformance and and reliability, you are currently reliability over time revamping existing plants to (up to 60 years).

3 Extend operational life and protection against intrusion, reduce risk. Whether you are attack, emergencies running a light-water reactor and natural catastrophes (Pressurized Water Reactor/. rapid response to technical PWR, French EPR/European requests and a long-term Pressurised Reactor, Russian supply of replacement cables VVER, or Boiling Water Reactor/BWR), a heavy-water R&D knowledge and support reactor (advanced CANDU for plant extension and type), a Gas Cooled Reactor, upgrades requires safe and reliable cables Nexans nuclear cables A complete range of cables help assure a clean source for quality and performance of economical energy reliability in extreme hot/cold, for coming generations.

4 Humidity, abrasion, vibration, etc. From basic power to complex fire-performance in emergency control and communications, situations: fire retardancy/. Nexans cables are omnipresent fire-resistance in the nuclear industry. low smoke and low toxicity To satisfy the most rigorous through halogen-free materials safety standards, Nexans has technical and R&D support designed exceptionally robust for total life management cables and developed a line of halogen-free cables that reduced construction costs keep operating during an due to standardized emergency, while protecting products people and infrastructure.

5 Quality assurance through We draw on 35 years experience ISO 9001/ISO 14001, in thermal, radiation and approved by AFAQ. design-based event testing. and IAEA 50 C/SG-Q. compliance with US NRC. Our close partnership with Regulatory Guide, ASME, nuclear engineers has meant NQA and IAEA Code cables customized and fully- of Practice adapted to nuclear needs. performance standards Where radiation-protection in keeping with IEC, NF, CSA, and LOCA (Loss of Cooling ASTM, ICEA, GOST, BS. Accident) procedures are re- quired for fast automatic shu- Specific nuclear tdown, Nexans manufactures qualifications highly reliable K1 (1E-LOCA) RCCE: Design and cables.

6 Elsewhere, K3 (1E non Construction Rules LOCA and non-1E) cables for Electrical Equipment assure flawless performance for Nuclear Island over a lifetime. Both K1 and CST/BTS: Book of K3 cables provide the highest technical specifications: levels of performance by Electrical Cables for limiting the spread of fire and Nuclear Power Plants emitting little smoke and toxic gases. IEEE 323: for nuclear power plant equipment IEEE 383: for (1) thermal aging, (2) radiation, and (3) LOCA test ; with (1). (2) and (3) for last day accident simulation, and (2) and (3) for first day of operation. Safety classification systems comparison Safety classified Not safety classified American 1E LOCA 1E non LOCA Non 1E.

7 Russian K0, K1 K3. Korean Q R. French K1 K3 Non Classified provides a full range of cables and accessories . THE NUCLEAR ISLAND THE CONVENTIONAL ISLAND. Houses the nuclear core, Instrumentation/ Contains the turbine, the Control/instrumentation/. steam generator and sensor cables AC generator and the sensor cables support systems which Individually or collectively condenser, plus additional Same as for Nuclear Island, feed the turbine in the screened multi-pair, triad safety equipment: averages but now they are controlling Conventional Island: or quad cables are used for 300-500 km of cables the pressure and temperature averages 1,800 km constant system surveillance per unit.

8 Of the steam going to the of fire-retardant and by measuring steam pressure, high-pressure and low pressure halogen-free cables water and component temper- LV XLPE cables turbine elements, and other per unit. ature, liquid levels, flow rates, and connectivity systems, including the condenser and vibration, etc. Copper (or aluminum) XLPE and heaters. They can be LV/MV energy cables energy cables are used to nuclear-qualified, according Nexans instrumentation/sensor These 1 kV to 10 kV cables are cables can be bi-metallic connect the generator to to customer requirements. used to power all the pumps (for thermocouples) and the HV transformer.

9 Nexans Nexans has provided these including the primary ones are designed according to K1 produces connectors, as well cables for both Ling Ao 3+4. which move water between and K3 requirements to offer as cable joints and terminations. (China), Temelin 1+2 (Czech the reactor vessel and the maximum reliability during These cables are widely used Republic), and other projects. steam generators in the normal operating conditions around the world by conven- containment area. and in the event of incidents tional electrical generating Access-control cables Nexans produced K3 and and accidents. systems. Secure cables that give a K1 cables for operation and simple on/off signal for doors, automatic shutdown for the EPR Control room cables ALSECURE fire-retardant gates, hatches, sliding panels, etc.

10 Taishan 1+2 project in China. and ALSECURE PLUS. With over 100,000 connections Nexans also designs special throughout the power plant, fire-resistant cables Control cables cables for motion detectors these cables are its nervous Energy cables (up to 1 kV) in sensitive nuclear plant areas. 500 V to 1,000 V control cables system, transmitting all crucial prevent fire propagation and are used to provide control energy and information: from dramatically reduce smoke for primary pumps, safety low-voltage systems for lighting, emission, while the latter valves, chemical and volume ventilation and climate to provide LV power for alarms, control, residual heat removal, measurement, control and smoke evacuation, lighting, containment sprinkling system telecommunications cables sprinklers and equipment (EAS), primary waste treatment, for safe operations.


Related search queries