Example: stock market

SAFETY DATA SHEET - Pestgon

SAFETY data SHEETP yrethrin FoggerSDS # : 6597-ARevision date: 2015-04-14 Format: NAVersion PRODUCT AND COMPANY IDENTIFICATIONP roduct Identifier Product NamePyrethrin FoggerOther means of identification Product Code(s)6597-ASynonyms(Z)-(S)-2-methyl-4- oxo-3-(penta-2,4-dienyl)cyclopent-2-enyl (1R,3R)-2,2-dimethyl-3-(2-methylprop-1-e nyl)cyclopropanecarboxylate5-[2-(2-butox yethoxy)ethoxymethyl]-6-propyl-1,3-benzo dioxole;5-[[2-(2-butoxyethoxy)ethoxy]met hyl]-6-propyl-1,3-benzodioxole N-(2-ethylhexyl)-8,9,10-trinorborn-5-ene -2,3-dicarboximide;2-(2-ethylhexyl)-3a,4 ,7,7a-tetrahydro-4,7-methano-1H-isoindol e-1,3(2H)-dioneActive Ingredient(s) pyrethrins , Piperonyl Butoxide, n-Octyl bicycloheptene dicarboximide (MGK264)Chemical FamilyPyrethrinsRecommended use of the chemical and restrictions on use Recommended Use:InsecticideRestrictions on Use:Use as recommended by the labelManufacturer Address FMC Corpo

Pyrethrin Fogger SDS # : 6597-A Revision date: 2015-04-14 Version 1.01 Synonyms are provided in Section 1. 4. FIRST AID MEASURES Eye Contact Hold eyes open and rinse slowly and gently with water for 15 to 20 minutes. Remove contact lenses, if present, after the first 5 …

Tags:

  Sheet, Data, Safety, Safety data sheet, Pyrethrins

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Advertisement

Transcription of SAFETY DATA SHEET - Pestgon

1 SAFETY data SHEETP yrethrin FoggerSDS # : 6597-ARevision date: 2015-04-14 Format: NAVersion PRODUCT AND COMPANY IDENTIFICATIONP roduct Identifier Product NamePyrethrin FoggerOther means of identification Product Code(s)6597-ASynonyms(Z)-(S)-2-methyl-4- oxo-3-(penta-2,4-dienyl)cyclopent-2-enyl (1R,3R)-2,2-dimethyl-3-(2-methylprop-1-e nyl)cyclopropanecarboxylate5-[2-(2-butox yethoxy)ethoxymethyl]-6-propyl-1,3-benzo dioxole;5-[[2-(2-butoxyethoxy)ethoxy]met hyl]-6-propyl-1,3-benzodioxole N-(2-ethylhexyl)-8,9,10-trinorborn-5-ene -2,3-dicarboximide;2-(2-ethylhexyl)-3a,4 ,7,7a-tetrahydro-4,7-methano-1H-isoindol e-1,3(2H)-dioneActive Ingredient(s) pyrethrins , Piperonyl Butoxide, n-Octyl bicycloheptene dicarboximide (MGK264)Chemical FamilyPyrethrinsRecommended use of the chemical and restrictions on use Recommended Use:InsecticideRestrictions on Use:Use as recommended by the labelManufacturer Address FMC Corporation1735 Market StreetPhiladelphia, PA 19103(215) 299-6000 (General (E-Mail General Information)Emergency telephone number For leak, fire, spill or accident emergencies, call.)

2 1 800 / 424 9300 (CHEMTREC - )1 703 / 527 3887 (CHEMTREC - Collect - All Other Countries)Medical Emergencies:1 800 / 331-3148 (PROSAR - & Canada)1 651 / 632-6793 (PROSAR - All Other Countries - Collect)2. HAZARDS IDENTIFICATIONC lassification OSHA Regulatory StatusThis material is considered hazardous by the OSHA Hazard Communication Standard (29 CFR )Acute toxicity - Inhalation (Dusts/Mists)Category 4 Page 1 / 9 Pyrethrin FoggerSDS # : 6597-ARevision date: 2015-04-14 Version sensitizationCategory 1 GHS Label elements, including precautionary statements EMERGENCY OVERVIEWP recautionary Statements - PreventionP261 - Avoid breathing dust/ fume/ gas/ mist/ vapors/ sprayP272 - Contaminated work clothing should not be allowed out of the workplaceP280 - Wear protective glovesP210 - Keep away from heat/sparks/open flames/hot surfaces.

3 - No smokingP211 - Do not spray on an open flame or other ignition sourceP251 - Do not pierce or burn, even after useP302 + P352 - IF ON SKIN: Wash with plenty of water and soapP333 + P313 - If skin irritation or rash occurs: Get medical advice/ attentionP363 - Wash contaminated clothing before reuseP304 + P340 - IF INHALED: Remove person to fresh air and keep comfortable for breathingP312 - Call a POISON CENTER or doctor if you feel unwellPrecautionary Statements - StorageP410 + P412 - Protect from sunlight. Do not expose to temperatures exceeding 50 C/ 122 FPrecautionary Statements - DisposalP501 - Dispose of contents/ container to an approved waste disposal plantHazards not otherwise classified (HNOC) No hazards not otherwise classified were Information No information available3.

4 COMPOSITION/INFORMATION ON INGREDIENTSC hemical nameCAS-NoWeight %n-Octyl bicycloheptene distillates, hydrotreated light64742-47-85-10 Isobutane75-28-55-10 Flammable AerosolsCategory 1 DangerHazard StatementsH317 - May cause an allergic skin reactionH332 - Harmful if inhaledPhysical HazardsH222 - Extremely flammable aerosolH229 - Pressurized container: May burst if heatedPage 2 / 9 Pyrethrin FoggerSDS # : 6597-ARevision date: 2015-04-14 Version are provided in Section FIRST AID MEASURESEye ContactHold eyes open and rinse slowly and gently with water for 15 to 20 minutes. Removecontact lenses, if present, after the first 5 minutes, then continue rinsing eye.

5 Call a poisoncontrol center or doctor for further treatment ContactTake off contaminated clothing. Rinse skin immediately with plenty of water for 15-20minutes. Call a poison control center or doctor for further treatment to fresh air. If person is not breathing, call 911 or an ambulance, then give artificialrespiration, preferably mouth-to-mouth if possible. Call a poison control center or doctor forfurther treatment call a poison control center or doctor. Do not induce vomiting unless told to doso by a poison control center or doctor. Do not give any liquid to the person. Do not inducevomiting or give anything by mouth to an unconscious important symptoms andeffects, both acute and delayedNone of immediate medicalattention and special treatmentneeded, if necessaryTreat FIRE-FIGHTING MEASURESS uitable Extinguishing MediaFoam.

6 Carbon dioxide (CO2). Dry chemical. Water Hazards Arising from theChemical Contents under data Sensitivity to Mechanical ImpactNot to Static DischargeNot equipment andprecautions for firefightersIsolate fire area. Evaluate downwind. In the event of fire, wear self contained ACCIDENTAL RELEASE MEASURESP ersonal PrecautionsIsolate and post spill area. Remove all sources of ignition. Ventilate the area. Wear suitableprotective clothing, gloves and eye/face protection. For personal protection see section 8. Ifventilation is not possible wear full protection suit and chemical protective further clean-up instructions, call FMC Emergency Hotline number listed in Section 1"Product and Company Identification" PrecautionsSee Section 12 for additional Ecological for ContainmentPrevent further leakage or spillage if safe to do for cleaning upTransfer damaged cartridges or cans to containers for later disposal.

7 Clean and neutralizespill area, tools and equipment by washing with bleach water and soap. Waste must beclassified and labeled prior to recycling or disposal. Dispose of waste as indicated inSection 13. Rinsate may be disposed at a waste water treatment HANDLING AND STORAGEPage 3 / 9 Pyrethrin FoggerSDS # : 6597-ARevision date: 2015-04-14 Version not contaminate other pesticides, fertilizers, water, food, or feed by storage or : Aerosol is pressurized. Keep away from direct sun exposure and temperaturesover 130 F. Do not open by force or throw into fire even after use. Do not spray on flamesor red-hot in a dry, cool and well-ventilated place.

8 Keep away from open flames, hot surfacesand sources of ignition. Keep out of reach of children and animals. Keep/store only inoriginal productsStrong oxidizing agents. Bases. Powdered earth EXPOSURE CONTROLS/PERSONAL PROTECTIONC ontrol parameters Chemical nameACGIH TLVOSHA PELNIOSHM exicoPyrethrins 8003-34-7 TWA: 5 mg/m3 TWA: 5 mg/m3 IDLH: 5000 mg/m3 TWA: 5 mg/m3 Mexico: TWA 5 mg/m3 Mexico: STEL 10 mg/m3 Propane 74-98-6 TWA: 1000 ppmTWA: 1000 ppmTWA: 1800 mg/m3 IDLH: 2100 ppmTWA: 1000 ppmTWA: 1800 mg/m3-Isobutane 75-28-5 STEL 1000 ppm-TWA: 800 ppmTWA: 1900 mg/m3-Chemical nameBritish ColumbiaQuebecOntario TWAEVA lbertaPyrethrins 8003-34-7 TWA: 5 mg/m3 TWA: 5 mg/m3 TWA: 5 mg/m3 TWA: 5 mg/m3 Propane 74-98-6 TWA: 1000 ppmTWA: 1000 ppmTWA: 1800 mg/m3 TWA: 1000 ppmTWA.

9 1000 ppmPetroleum distillates,hydrotreated light 64742-47-8 TWA: 200 mg/m3 Skin---Isobutane 75-28-5 TWA: 1000 ppm-TWA: 800 ppm TWA:1000 ppm-Appropriate engineering controlsEngineering measuresApply technical measures to comply with the occupational exposure limits. When working inconfined spaces (tanks, containers, etc.), ensure that there is a supply of air suitable forbreathing and wear the recommended protection measures, such as personal protective equipmentEye/Face ProtectionIf there is a potential for exposure to particles which could cause eye discomfort, wearchemical and Body ProtectionWear long-sleeved shirt, long pants, socks, and ProtectionProtective glovesRespiratory ProtectionIf exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approvedrespiratory protection should be worn.

10 Respiratory protection must be provided inaccordance with current local measuresClean water should be available for washing in case of eye or skin contamination. Washskin prior to eating, drinking, chewing gum or using tobacco. Shower or bathe at the end ofworking. Remove and wash contaminated clothing before re-use. Launder work clothingseparately from regular household informationIf the product is used in mixtures, it is recommended that you contact the appropriateprotective equipment suppliers These recommendations apply to the product as suppliedPage 4 / 9 Pyrethrin FoggerSDS # : 6597-ARevision date.


Related search queries