Transcription of SAFETY DATA SHEET Revision Date: 12.12
1 Page: 1 SAFETY data SHEET Revision date : Print date : SDS Number: R0524073 Tectyl MULTI PURPOSE 506 CORROSION INHIBITOR VE20086 Version: 1 / 24 Conforms to EU Regulation 1907/2006/EC as amended. - SDSGHS_GB SECTION 1: Identification of the substance/mixture and of the company/undertaking Product identifier Trade name : Tectyl MULTI PURPOSE 506 CORROSION INHIBITOR Relevant identified uses of the substance or mixture and uses advised against Recommended use : Corrosion inhibitor. Details of the supplier of the SAFETY data SHEET Ellis Enterprises , an affiliate of Valvoline Wieldrechtseweg 39 3316 BG Dordrecht Netherlands +31 (0)78 654 3500 (in the Netherlands), or contact your local CSR contact person Emergency telephone number 00-800-825-8654 / 001-859-202-3865, or contact your local emergency telephone number at 112 Product Information +31 (0)78 654 3500 (in the Netherlands), or contact your local CSR contact person SECTION 2.
2 Hazards identification Classification of the substance or mixture Classification (REGULATION (EC) No 1272/2008) Aerosols, Category 1 H222: Extremely flammable aerosol. H229: Pressurised container: May burst if heated. Specific target organ toxicity - single exposure, Category 3, Central nervous system H336: May cause drowsiness or dizziness. Label elements Labelling (REGULATION (EC) No 1272/2008) Page: 2 SAFETY data SHEET Revision date : Print date : SDS Number: R0524073 Tectyl MULTI PURPOSE 506 CORROSION INHIBITOR VE20086 Version: 2 / 24 Hazard pictograms : Signal word : Danger Hazard statements : H222 Extremely flammable aerosol.
3 H229 Pressurised container: May burst if heated. H336 May cause drowsiness or dizziness. Supplemental Hazard Statements : EUH066 Repeated exposure may cause skin dryness or cracking. Precautionary statements : P101 If medical advice is needed, have product container or label at hand. P102 Keep out of reach of children. Prevention: P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking. P211 Do not spray on an open flame or other ignition source. P251 Do not pierce or burn, even after use. P271 Use only outdoors or in a well-ventilated area.
4 Storage: P405 Store locked up. P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 C/ 122 F. Disposal: P501 Dispose of contents/ container to an approved waste disposal plant. Hazardous components which must be listed on the label: Hydrocarbons, C9-C11, n-alkanes, iso-alkanes,cyclenes, <2% aromatics Other hazards This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of or higher. Additional advice No information available.
5 SECTION 3: Composition/information on ingredients Mixtures Page: 3 SAFETY data SHEET Revision date : Print date : SDS Number: R0524073 Tectyl MULTI PURPOSE 506 CORROSION INHIBITOR VE20086 Version: 3 / 24 Hazardous components Chemical name CAS-No. EC-No. Registration number Classification (REGULATION (EC) No 1272/2008) Concentration (%) Hydrocarbons, C9-C11, n-alkanes, iso-alkanes,cyclenes, <2% aromatics 01-2119463258-33-xxxx Flam. ; H226 STOT SE3; H336 Asp. ; H304 >= 20,00 - < 25,00 Sulfonic acids, petroleum, sodium salts 68608-26-4 271-781-5 01-2119527859-22-xxxx Eye ; H319 >= 1,00 - < 2,50 2-(2-Heptadec-8-enyl-2-imidazolin-1-yl)ethanol 95-38-5 202-414-9 01-2119777867-13-xxxx Acute ; H302 Skin ; H314 Eye ; H318 STOT RE2; H373 Aquatic Acute1; H400 Aquatic Chronic1; H410 >= 0,10 - < 0,25 (Z)-N-Methyl-N-(1-oxo-9-octadecenyl)glyc ine 110-25-8 203-749-3 01-2119488991-20-xxxx Acute ; H332 Skin ; H315 Eye ; H318 Aquatic Acute1.
6 H400 >= 0,10 - < 0,25 Substances with a workplace exposure limit : Butane 106-97-8 203-448-7 01-2119474691-32-xxxx Flam. Gas1; H220 Press. GasLiquefied gas; H280 >= 15,00 - < 25,00 (2-Methoxymethylethoxy)propanol 34590-94-8 252-104-2 01-2119450011-60-xxxx >= 1,00 - < 2,50 For explanation of abbreviations see section 16. SECTION 4: First aid measures Description of first aid measures General advice : Move out of dangerous area. Call a POISON CENTRE or doctor/physician if exposed or you feel unwell. Show this SAFETY data SHEET to the doctor in attendance.
7 Do not leave the victim unattended. Page: 4 SAFETY data SHEET Revision date : Print date : SDS Number: R0524073 Tectyl MULTI PURPOSE 506 CORROSION INHIBITOR VE20086 Version: 4 / 24 If inhaled : Move to fresh air. If unconscious, place in recovery position and seek medical advice. Consult a physician after significant exposure. In case of skin contact : First aid is not normally required. However, it is recommended that exposed areas be cleaned by washing with soap and water. In case of eye contact : Flush eyes with water as a precaution.
8 Remove contact lenses. Protect unharmed eye. If eye irritation persists, consult a specialist. If swallowed : Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician. Most important symptoms and effects, both acute and delayed Symptoms : No symptoms known or expected. Risks : May cause drowsiness or dizziness. Repeated exposure may cause skin dryness or cracking. Indication of any immediate medical attention and special treatment needed Treatment : No hazards which require special first aid measures.
9 SECTION 5: Firefighting measures Extinguishing media Suitable extinguishing media : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Water spray Foam Alcohol-resistant foam Carbon dioxide (CO2) Dry chemical Unsuitable extinguishing media : High volume water jet Special hazards arising from the substance or mixture Specific hazards during firefighting : Never use welding or cutting torch on or near drum (even empty) because product (even just residue) can ignite Page: 5 SAFETY data SHEET Revision date : Print date : SDS Number: R0524073 Tectyl MULTI PURPOSE 506 CORROSION INHIBITOR VE20086 Version: 5 / 24 explosively.
10 Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas. Do not allow run-off from fire fighting to enter drains or water courses. Hazardous combustion products : carbon dioxide and carbon monoxide Hydrocarbons sulfur compounds Aldehydes Advice for firefighters Special protective equipment for firefighters : In the event of fire, wear self-contained breathing apparatus. Specific extinguishing methods : Product is compatible with standard fire-fighting agents. Further information : Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.