Transcription of Safety Data Sheet SECTION 1: Identification - …
1 3M Fluorinert Electronic Liquid FC-770 11/18/13_____ Page 1of 9 Safety data SheetCopyright,2013,3M rights reserved. Copying and/or downloading of this information for the purpose of properly utilizing 3M products is allowed provided that: (1) the information is copied in full with no changes unless prior written agreement is obtained from 3M, and (2)neither the copy nor the original is resold or otherwise distributed with the intention of earning a profit Group:22-7641-8 Version Date:11/18/13 Supercedes Date: 08/21/13 SECTION 1: Product identifier3M Fluorinert Electronic Liquid FC-770 Product Identification Numbers98-0212-3393-1, 98-0212-3527-4, 98-0212-3560-5, ZF-0002-1623-2, ZF-0002-1624-0, ZF-0002-1625-7, Recommended use and restrictions onuseRecommended useFor industrial use only; not intended for use as a medical device or drug.
2 , Heat transfer on use3M Electronics Markets Materials Division (EMMD) will not knowingly sample, support, or sell its products for incorporation in medical and pharmaceutical products and applications in which the 3M product will be temporarily or permanently implanted into humans or animals. The customer is responsible for evaluating and determining that a 3M EMMD product is suitable and appropriate for its particular use and intended application. The conditions of evaluation, selection, and use of a 3M product can vary widely and affect the use and intended application of a 3M product.
3 Because many of these conditions are uniquely withinthe user s knowledge and control, it is essential that the user evaluate and determine whether the 3M product is suitable and appropriate for a particular use and intended application, and complies with all local applicable laws, regulations, standards, and Supplier s detailsMANUFACTURER: 3 MDIVISION: Electronics Markets Materials DivisionADDRESS: 3M Center, St. Paul, MN 55144-1000, USAT elephone:1-888-3M HELPS (1-888-364-3577) Emergency telephone number1-800-364-3577 or (651) 737-6501 (24 hours) SECTION 2: Hazard Hazard classificationNot classified as hazardous according to OSHA Hazard Communication Standard, 29 CFR Label elementsSignal wordNot Fluorinert Electronic Liquid FC-770 11/18/13_____ Page 2of 9 SymbolsNot Hazards not otherwise 3: Composition/information on by WtPerfluoro N-alkyl morpholines, C=1,31093615-61-2100 SECTION 4: First aid Description of first aid measuresInhalation.
4 Remove person to fresh air. If you feel unwell, get medical Contact: Wash with soap and water. If signs/symptoms develop, get medical Contact: Flush with large amounts of water. Remove contact lenses if easy to do. Continue rinsing. If signs/symptoms persist, get medical Swallowed: Rinse mouth. If you feel unwell, get medical Most important symptoms and effects, both acute and delayedSee SECTION Information on toxicological Indication of any immediate medical attention and special treatment requiredNot applicableSECTION 5: Fire-fighting Suitable extinguishing mediaNon-combustible.
5 Choose material suitable for surrounding fire. Use a fire fighting agent suitable for the surrounding Special hazards arising fromthe substance or mixtureExposure to extreme heat can give rise to thermal Decomposition or By-ProductsSubstanceConditionCarbon monoxideDuring CombustionCarbon dioxideDuring CombustionHydrogen FluorideDuring CombustionToxic Vapor, Gas, ParticulateDuring Combustion3M Fluorinert Electronic Liquid FC-770 11/18/13_____ Page 3of Special protective actions for fire-fightersWhen fire fighting conditions are severe and total thermal decomposition of the product is possible, wear full protective clothing, including helmet, self-contained, positive pressure or pressure demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering for exposed areas of the 6.
6 Accidental release Personal precautions, protective equipment and emergency proceduresVentilate the area with fresh air. Refer to other sections of this SDS for information regarding physical and health hazards, respiratory protection, ventilation, and personal protective Environmental precautionsAvoid release to the environment. For larger spills, cover drains and build dikes to prevent entry into sewer systems or bodies of Methods and material for containment and cleaning upContain spill. Working from around the edges of the spill inward, cover with bentonite, vermiculite, or commercially available inorganic absorbent material.
7 Mix in sufficient absorbent until it appears dry. Remember, adding an absorbent material does not remove a physical, health, or environmental hazard. Collect as much of the spilled material as possible. Place in a closed container approved for transportation by appropriate authorities. Clean up residue with an appropriate solvent selected by a qualified and authorized person. Ventilate the area with fresh air. Read and followsafety precautions on the solvent label and SDS. Seal the container. Dispose of collected material as soon as 7: Handling and Precautions for safe handlingDo not breathe thermal decomposition products.
8 For industrial or professional use only. Do not eat, drink or smoke when using this product. Wash thoroughly after Conditions for safe storage including any incompatibilitiesNo special storage 8: Exposure controls/personal Control parametersOccupational exposure limitsNo occupational exposure limit values exist for any of the components listed in SECTION 3 of this Exposure Engineering controlsProvide appropriate local exhaust when product is Personal protective equipment (PPE)Eye/face protectionNone protectionSkin protection is not Fluorinert Electronic Liquid FC-770 11/18/13_____ Page 4of 9 Respiratory protectionDuring heating.
9 Use a positive pressure supplied-air respirator if there is a potential for over exposure from an uncontrolled release, exposure levels are not known, or under any other circumstances where air-purifying respirators may not provide adequate protection. SECTION 9: Physical and chemical Information on basic physical and chemical propertiesGeneral Physical Form: Liquid Specific Physical Form: LiquidOdor, Color, Grade: Colorless, clear thresholdNo data AvailablepHNot ApplicableMelting pointNot ApplicableBoiling Point96 CFlash PointNo flash pointEvaporation [Ref Std: BUOAC=1]Flammability (solid, gas)Not ApplicableFlammable Limits(LEL)None detectedFlammable Limits(UEL)None detectedVapor mmHg [@ 20 C]Vapor [Ref Std: AIR=1] g/mlSpecific [Ref Std.]
10 WATER=1]Solubility In mg/l [@ 23 C]Solubility-non-waterNo data AvailablePartition coefficient: n-octanol/ waterNo data AvailableAutoignition temperatureNo data AvailableDecomposition temperatureNot centistoke [@ 25 C ]Volatile Organic CompoundsNo data AvailablePercent volatile100 %VOC Less H2O & Exempt SolventsNo data AvailableSECTION 10: Stability and ReactivityThis material is considered to be non reactive under normal use Chemical stabilityStable. Possibility of hazardous reactionsHazardous polymerization will not occur. Conditions to avoidNone Fluorinert Electronic Liquid FC-770 11/18/13_____ Page 5of Incompatible materialsNone Hazardous decomposition productsSubstanceConditionNone to SECTION for hazardous decomposition products during the product is exposed to extreme condition of heat from misuse or equipment failure, toxic decomposition products that include hydrogen fluoride and perfluoroisobutylene can 11.