Date: Customer: Project: Type: Qty: Saturn 2 Cutoff LED. SAC2L - - - - - - - - Order Code: Pole Order Code: - - - Series Height Finish Options SAC2L Series SAC2L. Saturn 2 Cutoff LED. Optics R1 R2 R3 R5. Type I Type II Type III Type V. Distribution Distribution Distribution Distribution Mounting 1 1A 2 W. Single Single Arm Double Wall Mount Mount Light Engine LG4500 LG4700 LG4105. 500 mA/51W 700 mA/65W 1050 mA/101W. CCT 30* 35 40 50 *IDA Approved 3000K 3500K 4000K 5000K for other CCT please consult factory Power Cord 81,2 101,2 121,2 141,2 161,2 181,2 XX1,2 For 1 mounting use the pole height 1. For 1A or 2 mounting use the pole 2. Length 8' 10' 12' 14' 16' 18' XX' height +2. Finish WH BK BZ SV SP. White Black Bronze Silver Specify Premium Color Voltage 120 208 240 277 347* 480*. *Equipped with step-down transformer Options DS HS FS3 PCT DM6,7 DMY4 HLxx5,6, 7 3.

Page 2 of 13 (Rev. 07/2018) SAC2L_SSv3.7 In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not

Tags:

  Saturn, Saturn 2

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Saturn 2 Cutoff LED [SAC2L] selux

1 Date: Customer: Project: Type: Qty: Saturn 2 Cutoff LED. SAC2L - - - - - - - - Order Code: Pole Order Code: - - - Series Height Finish Options SAC2L Series SAC2L. Saturn 2 Cutoff LED. Optics R1 R2 R3 R5. Type I Type II Type III Type V. Distribution Distribution Distribution Distribution Mounting 1 1A 2 W. Single Single Arm Double Wall Mount Mount Light Engine LG4500 LG4700 LG4105. 500 mA/51W 700 mA/65W 1050 mA/101W. CCT 30* 35 40 50 *IDA Approved 3000K 3500K 4000K 5000K for other CCT please consult factory Power Cord 81,2 101,2 121,2 141,2 161,2 181,2 XX1,2 For 1 mounting use the pole height 1. For 1A or 2 mounting use the pole 2. Length 8' 10' 12' 14' 16' 18' XX' height +2. Finish WH BK BZ SV SP. White Black Bronze Silver Specify Premium Color Voltage 120 208 240 277 347* 480*. *Equipped with step-down transformer Options DS HS FS3 PCT DM6,7 DMY4 HLxx5,6, 7 3.

2 Not available with 347V or 480V. No Uplight House Side Single Fusing Photocell Dimming Dimming Hi-Lo Switching 4. LG4700 only 5. 120, 240, 277 only Finish Shield (180 ) Tenon (0-10V) (Dynadim) See p. 5 for details 6. LG4700, LG4105 only See p. 7 for 7. HL or DM. details Motion Sensor w/ Optional Photocell (Meets Title 24 Requirements). See Pole Spec Sheet for Order Code Product Modifications Approvals Please list modification requirements for review by factory: 5. YEAR. IP65. Date: LED WARRANTY. selux Corporation 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, Page 1 of 13. In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not (Rev. 07/2018). alter the function of the product. Specification sheets found at are the most recent versions and supercede all other printed or electronic versions.

3 Saturn 2 Cutoff LED. SAC2L-1-XX-DS. 28 3/8 (720mm). 1. 3 25 . (636mm). 6. 11 . 8 7 (279mm). (178mm). 7 5 3 1/8 (79mm). 3 1/8" [79mm]. Minimum Minimum PolePole For further details, please see installation instructions. Specifications 1. Luminaire Cover - Die cast aluminum cover 7. Pole Fitter - Self-leveling, die-cast low-cop- Standard exterior colors are White (WH), Black made from low copper alloy, designed to ensure per aluminum alloy, fitter base secured to pole (BK), Bronze (BZ), and Silver (SV). selux premium optimal thermal management for extra long life with three, stainless steel, Allen head set screws. colors (SP) are available, please specify from time of LED light engine. Fitter for 3 1/2 (90mm) poles. your selux color selection guide. 2. Gasketing - (not shown) Continuous gasket 8. Driver cover - Die cast aluminum cover made 5 Year Limited LED Luminaire Warranty - provides weatherproofing, dust and insect con- from low copper alloy, removes for tool-less ac- selux offers a 5 Year Limited Warranty to the trol at all fixture connections.

4 Cess to driver. Driver secured to removable tray original purchaser that the Saturn Cutoff LED. for ease of maintenance (shown painted matte luminaire shall be free from defects in material 3. Luminaire Hood - Aluminum shade with black for DS option). and workmanship for up to five (5) years from white painted interior. date of shipment. This limited warranty covers 9. Surge Protector - (not shown) Designed to the LED driver and LED array when installed and 4. L. ED Array - (not shown) High flux LEDs protect luminaire from electrical surge (10kA). operated according to selux instructions. For mounted to PC boards and attached to alumi- details, see selux Terms and Condition of Sale.. num heat sink for maximum LED performance 10. Hi-Lo Switching Option - (not shown). and life. CCT tolerance 1/4 step binning for Please see p. 5 for details.

5 Listings and Ratings: Luminaire and LED tested 3000K, 3500K and 4000K and ANSI standard to IP65 and IESNA LM-79-08 standards. LED. for 5000K. CRI minimum 80 for 3000K, 3500K 11. Power Cord - (not shown) Pre-installed at tested to LM-80 standards. Luminaire and LED. and 4000K and typical 80 for 5000K. Complete factory. Please specify power cord length in tested at 25 C ambient temperature. light engine can be removed easily for future accordance to height of the pole. Add 2 feet upgrade. LED light engine provides a reported to power cord length if double mounting (2) is For LG4500 and LG4700, luminaire suitable lumen maintenance of 94% at 60,000 hours. L70 specified. for ambient temperatures of 55 C (130 F). calculated greater than 100,000 hours. For LG4105, luminaire suitable for ambient Exterior Luminaire Finish - selux utilizes a temperature of 45 C (113 F).

6 Minimum op- 5. LED Driver - LEDs are driven by RoHS com- high quality Polyester Powder Coating. All selux erating temperature of luminaire at -35 C. pliant high-efficiency driver. Excellent for cold luminaires and poles are finished in our Tiger (-31 F). temperature starting and instant on. Standard Drylac certified facility and undergo a five stage driver for DMY option is Philips Xitanium Driver. intensive pretreatment process where product NRTL Listed ( UL, CSA). is thoroughly cleaned, phosphated and sealed. 6. Hood Supports - Two aluminum arms selux powder coated products provide excellent Visit for our LED End of Life support shade and optic assembly and attach salt and humidity resistance as well as ultravio- recycling policy. to the die cast aluminum pole fitter (shown let resistance for color retention. All products painted matte black for DS option).

7 Are tested in accordance with test specifications for coatings from ASTM and PCI. selux Corporation 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, Page 2 of 13. In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not (Rev. 07/2018). alter the function of the product. Specification sheets found at are the most recent versions and supercede all other printed or electronic versions. Saturn 2 Cutoff LED. Motion Sensor Features The selux outdoor rated sensor incorporates Passive Infrared (PIR) technology for motion sensing and also includes a built in photocell. Designed to mount directly through a 1/2 KO in a single gang faceplate on pole/column, the SBO utilizes 100% Digital Passive Infrared (PIR) technology that is tuned for walking size while preventing false tripping from the environment.

8 Hand Hole Photocell Series Optics Program Color Voltage Orientation Feature MS 1 2. 70 coverage - D0 (0V=0%) Y Yes UNV. 00 WH White Single Sensor Motion Sensor 09 D1 (1V=10%) BK Black N No 347. HAND HOLE REVISIONS. A LOCATION REV. ECN DESCRIPTION DATE BY APPR BY. 18 D3 (3V=30%) 480. XXXX BZISB ronze 01 POLE DEPICTED CREATED PLEASE. GENERIC FOR MARKETING 09/21/2016 FAH DRW. D5 (5V=50%) TO DETAIL MODIFICATION TO. TYPE 18 SHOWN27 A. REFERENCE. CUSTOMER. POLES ORDER. AND COLUMNS FOR FAH DRW. FOR SPECIFIC POLE MODEL NUMBER. SENSOR MOUNTING ORIENTATION 07/12/2017. LOGIC. 12". 12 . (305mm) General Pole Drawing For .500. Example Only 4 X .136 THRU. 8-32 UNC THRU..500. Nominal NOMINAL. POLE. Pole HEIGHT. Height 12" 2 X .188 THRU. NOMINAL. POLE HEIGHT. D. SC. Sensor Angular Orientation SENSOR from hand ANGULAR ORIENTATION hole FROM 0 HOLE.

9 HAND in 90 0 increments X .188 THRU. clockwise around IN 90 poleCLOCKWISE. INCREMENTS (Type 00, 09, 18, AROUND 27). POLE (TYPE 00, 09,18, 27). 90 . 90 (09). (09). DETAIL A. SCALE 1 : 1 SENSOR ANGULAR ORIENTATION FROM HAND. IN 90 INCREMENTS CLOCKWISE AROUND POLE (TYPE. TYPE 09 (90 ). Hand Hole Location HAND HOLD. 0 (00) 180 (18). LOCATION 0 (00) 180 (18). HAND HOLD. R ANGULAR ORIENTATION FROM HAND HOLE 0 LOCATION. TYPE 00 (0 ). ENTS CLOCKWISE AROUND POLE (TYPE 00,09,18,27). TYPE 09 (90 ). TYPE 27 (270 ). TOP VIEW. 270 . 270 (27). (27). D. TYPE 18 (180 ). ). selux Corporation 2018, T 845-834-1400, 800-735-8927, F 845-834-1401, Page 3 of 13. In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials that in our opinion will not (Rev. 07/2018). TYPE 27of alter the function (270 ).

10 The product. Specification sheets found at are the most recent versions and supercede all other printed or electronic versions. TOP VIEW. 01 XXXX CREATED FOR MARKETING 09/21/2016 FAH DRW. TO DETAIL MODIFICATION TO. A POLES AND COLUMNS FOR FAH DRW. SENSOR MOUNTING ORIENTATION 07/12/2017. LOGIC. Saturn 2 Cutoff LED. Motion Sensor Features 100% Digital PIR Detection, excellent RF Immunity General Pole Drawing For 270 coverage pattern Example Only 4 X .136 THRU. Up to 30ft mounting 8-32 UNC THRU..500 IP66 Rated for outdoor applications Built-in 1kV surge protection No minimum load requirements Made for LED light source Interchangeable hot and load wires - impossible backwards to Adjustable time delays, max/min dim levels and ramp rates Programming button accessible without opening sensor or removing gaskets No field calibration or sensitivity adjustments required Non-volatile setting memory Convenient test mode Suitable for Title 24 applications Motion Sensor Wiring.