Example: stock market

SCANDINAVIAN HOMES LTD.

SCANDINAVIAN HOMES LTD. House catalogue 2019. Version:Cat2019 Mar 2019. All types and styles can be mixed, ask us for more plans and images. Visit our website for more ideas: Concept Design An energy efficient house functions as a system. When all parts of the system are We offer four series of houses (Atlantica, designed to be compatible, each operates Baltica, Nordica and Hibernia). All houses more effectively and efficiently. In a are built to the same basic specification. house with a leaky building envelope, The series differ from each other only in neither the insulation nor a well designed ---walls in the factory--- the width of the main body of the and installed ventilation and heat- building.

House catalogue 2019 SCANDINAVIAN HOMES LTD. All types and styles can be mixed, ask us for more plans and images. Version:Cat2019/18.339/12 Mar 2019 Visit our website for more ideas: www.scanhome.ie

Tags:

  Scandinavian

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SCANDINAVIAN HOMES LTD.

1 SCANDINAVIAN HOMES LTD. House catalogue 2019. Version:Cat2019 Mar 2019. All types and styles can be mixed, ask us for more plans and images. Visit our website for more ideas: Concept Design An energy efficient house functions as a system. When all parts of the system are We offer four series of houses (Atlantica, designed to be compatible, each operates Baltica, Nordica and Hibernia). All houses more effectively and efficiently. In a are built to the same basic specification. house with a leaky building envelope, The series differ from each other only in neither the insulation nor a well designed ---walls in the factory--- the width of the main body of the and installed ventilation and heat- building.

2 Recovery system will function advantageously. Similarly, a building with All houses are fully customizable and can a very tight envelope will not be energy Features have any floor plan layout you wish. There are also many features available to efficient without sufficient insulation of the walls, windows, floors and roof. individualize the house design, which are featured in the following column but we ---Floor are also always open to new ideas. The concrete foundation slab is contained on its perimeter within However, the passive house concept specially made insulated base units.

3 It encourages you to minimize the area of sits on 280mm of insulation. the thermal envelope as this has a large U-value: W/m K impact on the energetic performance of the house. ---Walls The walls are at least 145mm timber framed with 145mm insulation. In most cases they are upgraded on site by a further 70mm or even 190mm of insulation. The wall is back ventilated ---roof trusses--- so that any water that may have entered the first layer can safely run and dry off. Ventilation & Heating U-value: - W/m K. ---Roof A constant replacement of all air, with as For a single storey building we specify little heat loss as possible, is the ideal 500mm of insulation above the condition for all houses.

4 When the sole ceiling. For a house with a converted ---corner and long windows--- concern is fresh air, simple fans may be attic the flat part above the first floor used to continuously exhaust stale air also contains 500mm of insulation, We also welcome customer designs and from specific rooms, with fresh air while the slope typically consists of ideas as long as they are feasible and entering through controllable slots in 400-500mm insulation. The roof is buildable with our modular system. There external walls. However the higher the ventilated below the sarking from are many easy to use and free programs price of energy, the more economically eaves to ridge, where the air exits you can use to make your own sketches attractive the concept of heat-recovery.

5 A through gills. but you can also engage our experienced heat-recovery ventilation system without U-value: - W/m K in-house architect for more ideas and an air-heater does not provide any new plans for your planning application. heat - it only saves existing heat. To heat ---Windows the house, any source or form of heat, All windows are timber with triple- such as underfloor heating, radiators, glazed low emmission glass on the stoves, etc. run by oil, gas, sun, solid fuel inside and argon gas in the two 12mm or electricity may be used in conjunction gaps between the panes.

6 With the system if necessary. U-value: W/m K. ---Doors Entrance doors are typically 60mm insulated sandwich doors. Some of them can have windows. U-value: - W/m K. ---dormers--- All our houses are constructed using a modular production system. ---roof trusses and walls ready to be shipped--- ---wooden extensions--- ---porches--- ---traditional barged gable finish--- How our houses are Atlantica The Atlantica model is the narrowest house from our range. It has the same external width as the traditional cottages of rural Ireland, but is much wider inside because the external walls are not as thick.

7 A standard roof pitch of 30 can be increased up to 45 . Baltica The Baltica is also a relatively narrow structure, and with increased roof pitch, its dimensions are similar and in proportion to the traditional farm houses in the Irish landscape. This feature makes it a good choice in locations where an indigenous shape is preferable or is stipulated in the planning regulations. Nordica This is the best-selling house type in the range. It is a relatively wide structure, and therefore has a relatively small surface area. This characteristic makes the Nordica more economical to produce and very energy efficient to operate - especially if the site allows the windows to be positioned so as to get maximum benefit from passive solar radiation.

8 Hibernia This is the latest house type in our range. It is a wide bodied structure which is suitable as a large home or for other uses. Having a relatively wide structure means the Hibernia is energy efficient because of it's small surface area relative to floor area. SCANDINAVIAN HOMES code A041-35-SHI. Passive House long codeSeries Atlantica Series (Uwall= W/m K, Uroof= W/m K). 100m . 4m . 39. (Gross Internal Area) drawing not to scale N. W E. Internal dimensions: m x m Fridge External dimensions: m x m S Bathroom DW. Bedroom 2 m2. m2.

9 This sample model shows that even a very 9-21. small house can be attractive and charming. 21. 9- The same house could also be built with a Kitchen/dining/living plaster finish and barged gables. 9- 21. m2. It can be used as a modest cottage with up to Bedroom 1 two bedrooms or as a holiday batch or granny m2. flat. East Elevation North Elevation Mar 2019. South Elevation West Elevation SCANDINAVIAN HOMES Ltd., Moycullen, H91YX61, Ireland | | Tel: 091-555 808 | SCANDINAVIAN HOMES code A061-45-SHI. Passive House long codeSeries Atlantica Series (Uwall= W/m K, Uroof= W/m K).

10 100m . 5m . 101. (Gross Internal Area) drawing not to scale N. 5. 4. 3. 2. 1. 6. F/F. 72 0. =2. W E 194. 14 x 7. Bathroom 8 m2. S. Kitchen 9. m2. Bedroom 1. DW. m2. 4. Hall WM. 2. 3. 1 m 2. Dining/living m2. Internal dimensions: m x m Bedroom 2. External dimensions: m x m m2. This model has the same width as the Atlantica 41 but is longer and has a converted attic with a 45 roof pitch. 5. 4. 3. 2. 1. 6. 72 0. =2. 194. 7 14 x It is a great house size for a medium family, 8. 9. Bathroom 2. especially where planning regulations require 10. m2.


Related search queries