user GUIDESCB-100A100-Pin shielded screw terminal DAQ AccessoryThe NI SCB-100A is a shielded I/O connector block with 100 screw terminals for easy signalconnection to National Instruments Digital I/O products (PCI-DIO-96, NI 6508, NI 6509,NI 6511, NI 6512, NI 6513, NI 6514, NI 6515, NI 6528, and NI 6529), Counter/Timerproducts (NI 6624), or other products with a 100-Pin series shielded D-type I/Oconnector. This document describes how to connect and use the SCB-100A with 100-Pin dataacquisition (DAQ) products, and lists 1. SCB-100A Parts Locator DiagramSCB-100A Quick Reference LabelStatic DIO and TIO DevicesDIGITAL19202122232425262728293031 323334J316 Position terminal Block16 Position terminal BlockDIGITAL213456789101112131415161718J 216 Position terminal BlockDIGITAL8483858687888990919293949596 979899100J716 Position terminal BlockDIGITAL3536373839404142434445464748 4950J4 DIGITAL51525354555657585960616263646566J 516 Position terminal Block16 Position terminal BlockDIGITAL6768697071727374757677787980 8182J613256541.

USER GUIDE SCB-100A 100-Pin Shielded Screw Terminal DAQ Accessory The NI SCB-100A is a shielded I/O connector block with 100 screw terminals for easy signal

Tags:

  Guide, User, User guide, National, Screw, Terminal, Accessory, Shielded, User guide scb, Shielded screw terminal daq accessory

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of SCB-100A USER GUIDE 100-Pin ... - National …

1 user GUIDESCB-100A100-Pin shielded screw terminal DAQ AccessoryThe NI SCB-100A is a shielded I/O connector block with 100 screw terminals for easy signalconnection to National Instruments Digital I/O products (PCI-DIO-96, NI 6508, NI 6509,NI 6511, NI 6512, NI 6513, NI 6514, NI 6515, NI 6528, and NI 6529), Counter/Timerproducts (NI 6624), or other products with a 100-Pin series shielded D-type I/Oconnector. This document describes how to connect and use the SCB-100A with 100-Pin dataacquisition (DAQ) products, and lists 1. SCB-100A Parts Locator DiagramSCB-100A Quick Reference LabelStatic DIO and TIO DevicesDIGITAL19202122232425262728293031 323334J316 Position terminal Block16 Position terminal BlockDIGITAL213456789101112131415161718J 216 Position terminal BlockDIGITAL8483858687888990919293949596 979899100J716 Position terminal BlockDIGITAL3536373839404142434445464748 4950J4 DIGITAL51525354555657585960616263646566J 516 Position terminal Block16 Position terminal BlockDIGITAL6768697071727374757677787980 8182J613256541.

2 Top Cover (Required)2. Quick Reference Label3. Enclosure Base4. SCB-100A Board Assembly5. Strain-Relief Screw6. Strain-Relief BarCaution This icon denotes a caution, which advises you of precautions to take toavoid injury, data loss, or a system crash. When this symbol is marked on a product,refer to the Safety Guidelines section for information about precautions to GuidelinesThe following cautions contain important safety information concerning hazardous voltagesand connector Do not connect hazardous voltages (>30 V RMS/42 V peak/60 V DC).Refer to your product documentation for information about the electrical limits ofyour device or Install cover prior to use. To avoid electrical shock, do not removeSCB-100A covers unless you are qualified to do so.

3 Before removing the cover,disconnect any live circuit from the connector block. Replace cover for The chassis ground lug on your SCB-100A is for groundinghigh-impedance sources, such as a floating source (1 mA maximum) and forterminating the shields of connected cables. Do not use the chassis ground lug as asafety earth Compatibility GuidelinesThis product was tested and complies with the regulatory requirements and limits forelectromagnetic compatibility (EMC) as stated in the product specifications. Theserequirements and limits are designed to provide reasonable protection against harmfulinterference when the product is operated in its intended operational product is intended for use in residential, commercial, and industrial locations. However,harmful interference may occur in some installations or when the product is connected to aperipheral device or a test object.

4 To minimize interference with radio and television receptionand prevent unacceptable performance degradation, install and use this product in strictaccordance with the instructions in the product , any changes or modifications to the product not expressly approved by NationalInstruments could void your authority to operate it under your local regulatory To ensure the specified EMC performance, operate this product only withshielded cables and To ensure the specified EMC performance, signal wires routed outside ofthe enclosure must be contained within a shielded cable and connected to shieldedaccessories. Cable shields must be terminated to the chassis ground lug using asshort a connection as is | | SCB-100A user GuideWhat You Need to Get StartedTo set up and use your SCB-100A , you need the items shown in the following figure.

5 You canfind quick reference labels, which specify accessory pinout information for many compatibleproducts, by going to and entering the Info Code 2. SCB-100A Installation Supply List2345789611. SCB-100A 100-Pin shielded Connector Block Kit2. 100-Pin DAQ Device/Module and Documentation3. (Optional) Quick Reference Label PDF4. SH100-100-F Cable (Part Number 185095-0x)5. #2 Phillips Screwdriver6. in. Flathead Screwdriver7. 16 AWG to 30 AWG Signal Wire8. Wire Cutters9. Wire Insulation StripperGetting Started with the SCB-100 AThe following figure shows the SCB-100A printed circuit board (PCB) parts locator the kit is missing any of the components in the figure, contact user GUIDE | National Instruments | 3 Figure 3. SCB-100A PCB Diagram40 SCB - 100A COPYRIGHT 2016 1218UL94V 0J2J111811811611716151413121110978654319 203433323130292827252624232221353650 FOR PATENTS: / PATENTS494847464544434142403938376768828 1807978777675737472717069838498100999796 9594939291899088878685515266656463626160 59575856555453 CAUTION: SEE MANUAL FOR ELECTRICAL RATINGSCAUTION: INSTALL COVER PRIOR TO USEJ316116J5J7J4161J61111112431.

6 screw Terminals2. 100-Pin I/O Connector3. PCB Mount Screw4. Chassis Ground Lug and PCB Mount ScrewCaution The chassis ground lug on your SCB-100A is for groundinghigh-impedance sources, such as a floating source (1 mA maximum) and forterminating the shields of connected cables. Do not use the chassis ground lug as asafety earth get started with the SCB-100A , complete the following steps while referring to theprevious figures. If you have not already installed your DAQ device or module, refer to the4 | | SCB-100A user Guidegetting started GUIDE that came with your product for instructions. Remove all cables from theSCB-100A before getting (Optional) Mount the SCB-100A to a panel or DIN rail, as described in the Mounting theSCB-100A Remove the Remove the film from both sides of the (Optional) Attach the quick reference label to the inside of the cover.

7 For quick referencelabels for most compatible products, go to and enter the Info You can stand the cover in the SCB-100A for easy Loosen the strain-relief bar by removing the strain-relief screws with a #2 Connect the wires to the screw terminals by stripping off the wire insulation, inserting thewires into the screw terminals, and securely tightening the screws with the flatheadscrewdriver. Refer to the Specifications section for screw - terminal wiring gauge andtorque To ensure the specified EMC performance, signal wires routedoutside of the enclosure must be contained within a shielded cable andconnected to shielded accessories. Cable shields must be terminated to thechassis ground lug using as short a connection as is Reinstall the strain-relief (if removed) and tighten the strain-relief screws.

8 If the shieldedcable is too large to route through the strain-relief hardware, either use multiple,smaller-diameter cables or remove the top strain-relief bar and add insulation or paddingif necessary to constrain the Replace the You must install cover prior to Do not connect input voltages >30 V RMS/42 V peak/60 V DC tothe SCB-100A . Input voltages >30 V RMS/42 V peak/60 V DC can damage theSCB-100A, all devices or modules connected to it, and the host Connect the SCB-100A to the DAQ device or module using the SH100-100-F to the Specifications section for information about the SCB-100A I/O To ensure the specified EMC performance, operate this product onlywith shielded Launch Measurement & Automation Explorer (MAX). In the left panel, expand Devicesand Interfaces to confirm that your DAQ device or module is recognized, and thenconfigure your device user GUIDE | National Instruments | 511.

9 (Optional) Configure the DAQ device or module connected to the SCB-100A bycompleting the following In MAX, right-click your DAQ device or module and select Configure the device or module properties and click Test specific device functionality. Run a Test Panel in MAX by right-clicking your DAQdevice or module and selecting Test Panels. Click Start to test the device or When you have finished using the SCB-100A , power off any external signalsconnected to the SCB-100A before you power off your the SCB-100 AYou can use the SCB-100A on a desktop, or mount it to a panel or a standard DIN rail. Fortwo-dimensional drawings and three-dimensional models of the SCB-100A , visit and search by product MountingThree keyholes are located on the back of the SCB-100A for mounting it to a panel or wall.

10 Tomount the SCB-100A to a board or panel, complete the following Download and print the panel mounting template PDF by going to andentering the Info Code Using the template, mark the three points on the panel. Verify that the narrow ends of thepanel mounting screw keyholes are pointing screw #6-32 panhead machine screws or M3 panhead machine screws into the pointsmarked on the panel, leaving room to easily remove the SCB-100A from the screw height for both screw types (from the wall to the top of the screw ) is5 mm ( in.).DIN Rail MountingThe NI 9913 DIN rail mounting kit (part number 781740-01) contains one clip for mountingthe SCB-100A on a standard 35 mm DIN rail. Fasten the DIN rail clip to the accessory usingtwo FLH #6-32 x 5/16" screws (included in the kit) with a #2 Phillips screwdriver, as shown inthe following The threaded holes on the SCB-100A for DIN rail mounting should not beused more than five times.