Screw limit switchesXRBA and XR2 Catalogue1 Screw limit switchesXRBA and XR2 Selection guide .. page 2 Screw limit switches for standard duty: XRBA Presentation .. page 4 Characteristics .. page 5 References .. page 6 Order form .. page 7 Screw limit switch selection example .. pages 8 and 9 Dimensions .. page 18 Screw limit switches for heavy duty: XR2 Presentation .. page 10 Characteristics .. pages 11 and 12 References ..pages 13 to 15 Dimensions .. page 18 Differential drive units Presentation and references .. page 17 Dimensions and mounting .. page 19 Contents21345678910213456789102 Screw limit switchesApplicationsStandard duty a or c (Ithe = 10 A)Heavy duty a or c (Ithe = 10 A) Number of contacts4 or 63, 4, 6, 10, 14, 20, 24 or 28 Conventional thermal current (Ithe)10 A10 AType of contactsSingle-pole C/O, snap actionSingle-pole C/O, snap actionReduction gear ratioFor 1 revolution of cams: 13/1, 17/1, 46/1, 60/1, 78/1, 210/1, 274/1 or 960/1 For 6 turns of threaded shaft: , , , 3/6, 6/6, 10/6, 20/6, 40/6, 80/6, 150/6, 300

5 Screw limit switches Standard duty, XRBA Environment Conformity to standards IEC/EN 60947-5-1 Protective treatment Standard version “TC” Special version “TH” on request Ambient air temperature For storage °C - 40…+ 70 For operation °C - 25…+ 70 Shock resistance 80 gn (11 ms) Vibration resistance > 5 gn (10…60 Hz) Degree of protection XRBA4 pppp: IP 55 conforming to IEC/EN ...

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Screw limit switches XRBA and XR2 - botekotomasyon.com

1 Screw limit switchesXRBA and XR2 Catalogue1 Screw limit switchesXRBA and XR2 Selection guide .. page 2 Screw limit switches for standard duty: XRBA Presentation .. page 4 Characteristics .. page 5 References .. page 6 Order form .. page 7 Screw limit switch selection example .. pages 8 and 9 Dimensions .. page 18 Screw limit switches for heavy duty: XR2 Presentation .. page 10 Characteristics .. pages 11 and 12 References ..pages 13 to 15 Dimensions .. page 18 Differential drive units Presentation and references .. page 17 Dimensions and mounting .. page 19 Contents21345678910213456789102 Screw limit switchesApplicationsStandard duty a or c (Ithe = 10 A)Heavy duty a or c (Ithe = 10 A) Number of contacts4 or 63, 4, 6, 10, 14, 20, 24 or 28 Conventional thermal current (Ithe)10 A10 AType of contactsSingle-pole C/O, snap actionSingle-pole C/O, snap actionReduction gear ratioFor 1 revolution of cams: 13/1, 17/1, 46/1, 60/1, 78/1, 210/1, 274/1 or 960/1 For 6 turns of threaded shaft: , , , 3/6, 6/6, 10/6, 20/6, 40/6, 80/6, 150/6, 300/6, 560/6 or 1100/6 Adaptation for potentiometerp Conformity to standardsIEC/EN 60947-5-1 IEC/EN 60947-5-1 Degree of protectionXRBA4: IP 55 conforming to IEC/EN 60529, IP 557 conforming to NF C 20-010 XRBA6.

2 IP 55 conforming to IEC/EN 60529, IP 555 conforming to NF C 20-010IP 54 conforming to IEC/EN 60529 Cable entry1 tapped entry for n 9 cable glandClamping capacity 5 to 8 mm1 tapped entry for n 16 cable glandClamping capacity 10 to 14 mm2 tapped entries for n 13 cable glandClamping capacity 9 to 12 mmMaterialsStainless steel input drive shaft Aluminium alloy body housingXRBA4: aluminium alloy coverXRBA6: polyphenylene oxide coverAluminium alloy body housing, insulated coverType referenceXRBAXR2 AAPages613 Selection guide3 Heavy duty a or c (Ithe = 10 A)Heavy duty a or c (Ithe = 20 A) 3, 4, 6, 10, 14, 20, 24 or 283, 5, 9, 13, 19, 23 or 2710 A20 ASingle-pole C/O, snap actionSingle-pole N/C or N/O, with snap action mechanismFor 6 turns of threaded shaft: , , , 3/6, 6/6, 10/6, 20/6, 40/6, 80/6, 150/6, 300/6, 560/6 or 1100/6 For 6 turns of threaded shaft.

3 , , , 3/6, 6/6, 10/6, 20/6, 40/6, 80/6, 150/6, 300/6, 560/6 or 1100/6 IEC/EN 60947-5-1 IEC/EN 60947-5-1IP 54 conforming to IEC/EN 60529IP 54 conforming to IEC/EN 60529 Removable gland plateRemovable gland plateSheet steel enclosureSheet steel enclosureXR2 ABXR2B13134 Screw limit switchesStandard duty, XRBAF unctionsThese switches are designed to monitor the movement of an object via an input drive shaft coupled to the actuator. Detection of position is ensured by a system of independently adjustable cams which actuate the electrical contact are usually used for applications where it is either impossible or impractical to mount standard type position sensors that are actuated directly by the moving applications:b position control of moving parts of hoisting or materials handling equipment (winches, travelling cranes, gantries, cranes, rotary excavators, etc.)

4 B liquid level control in pumping systems. Description 1 Input drive shaft2 Reduction gear3 Cams4 Contact blocks5 Potentiometer (option) OperationThe input drive shaft, which is coupled to the machine part being controlled, is normally fi tted on the right-hand side. This transmits the movement by means of a worm Screw and reduction gear to a set of 4 or 6 independent cams which, in turn, operate the contact choice of 3 cam types (20 , 50 and 80 ) enables a wide range of cam arrangements to be cams are easily accessible and individual adjustment of the cams is a simple operation, without risk of affecting the setting of adjacent an option, a potentiometer can be fi tted in order to provide an analogue limit switchesStandard duty, XRBAE nvironmentConformity to standardsIEC/EN 60947-5-1 Protective treatmentStandard version TC Special version TH on requestAmbient air temperatureFor storage C- + 70 For operation C- + 70 Shock resistance80 gn (11 ms)

5 Vibration resistance> 5 gn ( Hz)Degree of protectionXRBA4pppp: IP 55 conforming to IEC/EN 60529, IP 557 conforming to NF C 20-010 XRBA6pppp: IP 55 conforming to IEC/EN 60529, IP 555 conforming to NF C 20-010 MaterialsStainless steel input shaft. Aluminium alloy body alloy cover for XRBA4ppppPolyphenylene oxide cover for XRBA6ppppCable entry1 tapped entry for n 9 cable gland (clamping capacity 5 to 8 mm) and 1 tapped entry for n 16 cable gland (clamping capacity 10 to 14 mm)Mechanical characteristicsReduction gear ratioFor 1 revolution of cams13/1, 17/1, 46/1, 60/1, 78/1, 210/1, 274/1 or 960/1 Average drive torqueAt 20 speed of input drive shaftrpm1000 Mechanical durability15 x 106 drive shaft revolutionsElectrical characteristics of contactsType of contactsSingle-pole C/O, snap actionRated operational characteristicsConforming to IEC/EN 60947-5-1a AC-15, A300 (Ue = 240 V, Ie = 3 A), c DC-13, Q300 (Ue = 250 V, Ie = A)

6 Conventional thermal currentAIthe = 10 Rated insulation voltageConforming to IEC/EN 60947-1 VUi = 250 Rated impulse withstand voltageConforming to IEC/EN 60947-1kVUimp = 6 Resistance across terminalsmWy 25 Short-circuit protection10 A cartridge fuse type gGConnectionScrew and captive cable clamp terminals. Clamping capacity: 2 x mm2 with cable endClips or solder tags available on requestElectrical durabilityConforming to IEC/EN 60947-5-1 Utilisation categories: AC-15 and DC-13 Operating rate: 3600 operating cycles/hourLoad factor: supply a 50/60 supply c Power broken in VA for million operating cyclesPower broken in W for million operating cyclesVoltage (V)122448127 220 Voltage (V)122448110 220o1835700 165 220o2739506567865108 216 450 53085584110 130 135 Optional potentiometer characteristics (analogue output)Rotation ratio between cams and potentiometer1, ( ) or 2 ( )Maximum rotation angle of potentiometer350 Potentiometer typeType SI, size 15, ball bearing mountedPower.

7 3 WWithstand voltage: 1500 VOhmic values: 2200 , 4700 or 10 000 (other values available on request) References:page 6 Dimensions:page 18 Characteristics6 Screw limit switchesStandard duty, XRBAS crew limit switchesDescriptionNumber of contactsBasic reference, to be completed (1)WeightkgScrew limit switches (with bare drive shaft)4 XRBA4pppp components and replacement partsDescriptionTypeReferenceWeightkgCam s20 (2)XRBA901 (2)XRBA902 (2)XRBA903 blockShort roller lever actuator1 C/O snap action contact XEPA1081D64 glandsN 9 plastic, clamping capacity 5 to 8 mmDE9PL109041 16 plastic, clamping capacity 10 to 14 sprockets mm pitch, for switch input drive shaft12 teethXRBZ912 ( mm pitch) conforming to standard NF E 26-101, chromium plated, with joining link (3)

8 L = 2 = 5 = 10 Type SI, size 15, 3 W2200 XRBZ922 000 Ohmic valuesXRBZ900 (4) (1) For completion of the basic reference, please refer to Order form on page 7.(2) Average values.(3) For liquid level control applications, the length of the chain should at least be equal to the difference between the upper and lower liquid levels + m.(4) Following the reference XRBZ900, state clearly the required Ohmic value. XRBA4pppp 534926 XRBA901 XRBA902 XRBA903142 XEPA10801D64DE9PL109041 XRBZ91pXRBZ9ppCharacteristics:page 5 Dimensions:page 18 References7 Screw limit switchesStandard duty, XRBAC ustomerSchneider ElectricCompanyOrder N Delivery dateSales Offi ce - Subsidiary N To use this order form.

9 B State the number of identical Screw limit switches requiredb Complete the basic reference with the 5 digits indicating the various switch optionsb Mark the required cam arrangement on the drawing examples showing completion of the basic reference, refer to pages 8 and of identical switchesBasic reference, to be completedNumber of contactsReduction gear ratioDrive shaft positionAdaptation for potentiometerOhmic value of potentiometerXRBAN umber of contactsSwitch with 4 contacts4 Switch with 6 contacts6 Reduction gear ratio (for 1 revolution of cams)13/1117/1246/1360/1478/15210/16274/ 17960/18 Drive shaft positionRight-hand side (standard model)1 Left-hand side2 Adaptation for potentiometerWithout adaptation0 With adaptation, ratio 11 With adaptation, ratio ( )2 With adaptation, ratio 2 ( )3 Ohmic value of potentiometerWithout potentiometer0 With potentiometer, 2200 1 With potentiometer, 4700 2 With potentiometer, 10 000 3 With potentiometer, other Ohmic values (please state exact value)9 Required cam arrangementThe cam positioned nearest to the plate is considered as cam n 1 Marking guide for cam arrangement diagramMark the required cam arrangement Note: if the above cam arrangement diagram is left blank, the cams will be arranged as follows.

10 Cam n 123456 XRBA4pppp20 50 80 20 __XRBA6pppp20 20 50 50 80 80 16542320 50 80 20 50 80 Cam n 1 n 2 n 3 n 4 n 5 n 6 20 cam 50 cam 80 cam(average values)Order form(specimen suitable for photocopying)8 Screw limit switchesStandard duty, XRBAA pplication: monitoring the movement of a machine partExample:Monitoring the movement of a machine part from A to F (AF = m) with potentiometer linked sprocket on switch input drive shaft: 16 teeth on mm pitch. Point AStop position, direction F V APoint BSlow-down position, direction F V APoints C and DSpecifi c pointsPoint ESlow-down position, direction A V FPoint FStop position, direction A V FSelection of switch and completion of basic referenceb Number of contacts: 6 positions to monitor, therefore, 6 digit of reference:6b Reduction gear ratio: Distance AF = m, therefore, number of turns of input drive shaft.