IEC and British Standard Fuses 5 IEC and British Standard fusesContentsDescriptionSection pageFusesCSA Type P and D Fuses (CDN, CDS and PON)2 HRC Form II Class C Fuses (CGL)3 HRCI industrial ceramic body fusesHRCI-CA (CIF21)4 HRCI-CB (CIF06)HRCI-Misc. Type K (CIH, CIK and CIL)5 HRC Form II current-limiting Fuses (H07C, K07C, L14C, M14C, L09C, M09C, P09C, P11C, R11C)6BS88 Part 1 fusesSSD, NSD, ESD7 STD, NITD, AAO, BAO, OSD, CEO, DEOBS88AC, AD, BC, BD, CD, DD, ED, EFS8EF, FF, FG, GF, GG, GHDIN Type D Diazed (D16, D27, D33, D125)9 DIN Type N Neozed (NZ01, NZ02)NH HRC Fuses (NHG)10-11 JKS-700 fast-acting, current limiting UL Recognized and CSA Component Acceptance 700 Vac Fuses up to 60 amps11NH fuse blocks and accessories (SD, TD)

IEC and British Standard fuses — 5 IEC and British Standard fuses Contents Description Section page Fuses CSA Type P and D fuses (CDN, CDS and PON) 2

Tags:

  Series

Information

Domain:

Source:

Link to this page:

Please notify us if you found a problem with this document:

Other abuse

Transcription of Section Bussmann series IEC page Fuses cylindrical fuses

1 IEC and British Standard Fuses 5 IEC and British Standard fusesContentsDescriptionSection pageFusesCSA Type P and D Fuses (CDN, CDS and PON)2 HRC Form II Class C Fuses (CGL)3 HRCI industrial ceramic body fusesHRCI-CA (CIF21)4 HRCI-CB (CIF06)HRCI-Misc. Type K (CIH, CIK and CIL)5 HRC Form II current-limiting Fuses (H07C, K07C, L14C, M14C, L09C, M09C, P09C, P11C, R11C)6BS88 Part 1 fusesSSD, NSD, ESD7 STD, NITD, AAO, BAO, OSD, CEO, DEOBS88AC, AD, BC, BD, CD, DD, ED, EFS8EF, FF, FG, GF, GG, GHDIN Type D Diazed (D16, D27, D33, D125)9 DIN Type N Neozed (NZ01, NZ02)NH HRC Fuses (NHG)10-11 JKS-700 fast-acting, current limiting UL Recognized and CSA Component Acceptance 700 Vac Fuses up to 60 amps11NH fuse blocks and accessories (SD, TD)

2 12 Fuses continuedIEC 60269 industrial Fuses with and without indicator/strikerClass gG ferrule (C10G, C14G, C22G)13 Class aM ferrule (C10M, C14M, C22M)14 HRC fuse holdersCAMaster15 SAFElocRed SpotBussmann series IEC cylindrical fusesComplete portfolio of 8-22 mm diameter Class aM and Class gG cylindrical Fuses for industrial applications5-1 Bussmann series FULL LINE CATALOG 1007 JUNE IEC and British Standard fusesCDN, CDS and PON CSA Type P and D fusesCSA time-delay Type D and P Volts 250 Vac (CDN and PON) 600 Vac (CDS) Amps 10-600 A IR 10 kA minimumAgency information CSA Certified to No.

3 , CEFeatures Economical fuse in a variety of ratings for applications not requiring time-delayTypical applications Lighting, heating and other circuits not subject to temporary surges and where available short-circuit current are relatively lowCatalog no.*Catalog symbolVoltsAvailable amp ratingsTime-Delay CSA Type "D" fusesCDN**250 Vac10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125, 150, 175, 200, 225, 250, 300, 350, 400, 450, 500, 600 CDS 600 Vac10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100, 110, 125, 150,175, 200, 225, 250, 300, 350, 400, 450, 500, 600 One-time CSA Type "P" fusesPON250 Vac15, 20, 25, 30, 35, 40, 45, 50, 60* To order, specify catalog symbol and amp rating, , CDN30, CDS110 or PON40.

4 ** Below 10 amps, use FRN-R. Below 10 amps, use in (mm)AmpsABCDEFCDN/PON 250 VacUp to (51) (14) (76) (21) (149) (25) (3) (19) (185) (35) (105) (5) (29) (219) (48) (118) (6) (41) (264) (57) (132) (6)2 (51)CDS 600 VacUp to (127) (21) (140) (27) (200) (25) (3) (19) (245) (35) (116) (5) (29) (295) (48) (118) (6) (41) (340) (57) (208) (6)2 (51)Recommended fuse blocksCatalog no.*VoltsFuse amps250600Up to 30HM25030-(poles)HM60030-(poles)35-60HM2 5060-(poles)HM60060-(poles)70-100HM25100 -(poles)HM60100-(poles)110-200HM25200-(p oles)HM60200-(poles)225-400HM25400-(pole s)HM60400-(poles)450-600HM25600-(poles)H M60600-(poles)* To order, specify 1, 2 or 3 poles, , HM25030-2_.

5 See data sheets 10289 (30-60 A) and 3192 (70-600 A) for available to 600 A ABUp to 60 A Data sheet no. 41265-2 Bussmann series FULL LINE CATALOG 1007 JUNE and British Standard Fuses 5 IEC and British Standard fusesCGL HRC Form II Class C fusesCurrent-limiting HRCII-C Fuses designed to withstand inrush currents on typical motor start-ups while offering high current limitation in the short-circuit region. See drawings for Volts 600 Vac 250 Vdc (1-30 A) Amps 1-600 A IR 200 kA 40 kA DCAgency information CSA Certified, No. 106, Class 1422,File 53787, CECatalog no. (amps)CGL-1 CGL-25 CGL-80 CGL-225 CGL-2 CGL-30 CGL-90 CGL-250 CGL-3 CGL-35 CGL-100 CGL-300 CGL-4 CGL-40 CGL-110 CGL-350 CGL-6 CGL-45 CGL-125 CGL-400 CGL-10 CGL-50 CGL-150 CGL-450 CGL-15 CGL-60 CGL-175 CGL-500 CGL-20 CGL-70 CGL-200 CGL-600 Features Close sizing to loads allows using smaller and less costly switches Provides a higher degree of short-circuit protection Helps protect motors against burnout from overloadsTypical applications For use in circuits subject to surge currents such as those caused by motors.

6 Transformers and other inductive loadsAvailable Red Spot fuse holdersFuse ampsCatalog symbol*Up to 32RS32_35-60RS63_70-100RS100_110-200RS20 0_225-400RS400_* See Red Spot data sheet no. 10083 for terminal sheet no. ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )CGL 1-30 CGL ( ) ( ) ( ) ( ) ( ) ( )CGL ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )CGL ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )CGL ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )CGL ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( ) ( )Dimensions in (mm)5-3 Bussmann series FULL LINE CATALOG 1007 JUNE IEC and British Standard fusesCIF06 HRCI-CB industrial ceramic body fusesA miniature offset clip-in blade, ceramic body industrial fuse that provides both short-circuit and overload protection and the CIF06 fits the 30 A SAFEloc fuse holder (data sheet number 4133).

7 Ratings Volts 600 Vac 250 Vdc Amps 1-30 A IR 200 kA RMS information CSA No. 106-M92 (3-30 A only), CECatalog Close sizing to loads allows using smaller and less costly switches Provides a higher degree of short-circuit protection Helps protect motors against burnout from overloadsTypical applications For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loadsRecommended fuse holdersAmpsDescriptionCatalog no.*Up to 30 SAFElocC30(terminal option)* See data sheet no. 4133 for SAFEloc in (mm)Data sheet no. (60) (36) (14) (4) (13) (4)CIF21 HRCI-CA industrial ceramic body fusesThe HRCI-CA bolt-on, ceramic body fuse provides both overload and short-circuit protection to HRCI requirements.

8 Offset blades for bolt-on mounting CIF21 fuse fits the Bussmann series Red Spot fuse holder (data sheet 10083) and CAMaster fuse holder (data sheet number 4132).Ratings Volts 600 Vac 250 Vdc Amps 1-30 A IR 200 kA RMS information CSA , No. 106-M92, CECatalog Close sizing to loads allows using smaller and less costly switches Provides a higher degree of short-circuit protection Helps protect motors against burnout from overloadsTypical applications For use in circuits subject to surge currents such as those caused by motors, transformers and other inductive loadsRecommended fuse holdersAmpsDescriptionCatalog no.

9 *Up to 20 Red SpotRS20_(terminal option)Up to 30 CAMasterCM20CF* See data sheet no. 10083 (Red Spot) and 4132 (CAMaster) for in (mm)Data sheet no. (55) (36) (45) (5) (14) (11) (1)5-4 Bussmann series FULL LINE CATALOG 1007 JUNE and British Standard Fuses 5 IEC and British Standard fusesCIH, CIK and CIL HRCI Misc. Type K fusesMisc. Type K HRCI bolt-on, ceramic body Fuses provide both overload and short-circuit protection, featuring offset blades for bolt down Volts 600 V Amps 1-100 A IR 200 kA@600 VAgency information CSA No. 106-M92, CECatalog no. (amp)CIH, CIK, CIL1 CIH0715 CIH0735 CIK0780 CIL143 CIH0720 CIH0740 CIK0790 CIL146 CIH0725 CIH0750 CIK07100 CIL1410 CIH0730 CIH0760 CIK07 Dimensions in (mm)The CIL14 has a rejection hole, not a slot as shown to (57) (24) (86) (10) (1) (73) (5) (8)1 (25) (3) (60)35- (58) (27) (91) (13) (1) (73) (5) (11) (28) (3) (61)80- 10 (70) (37) ( 111 ) (19) (3) (94) (9) (11) (39) (74)Recommended fuse holdersAmpsRed Spot*CAMaster*Up to 30RS32_CM30CF35-60RS63_CM60CF80-100RS100 _ * See data sheet no.

10 10083 (Red Spot) and 4132 (CAMaster) for sheet no. 41305-5 Bussmann series FULL LINE CATALOG 1007 JUNE IEC and British Standard fusesHRC Form II current-limiting fusesHRC Form II bolt-on, ceramic body current-limiting Volts 600 Vac (or less) 250 Vdc Amps 2-600 A IR 200 kA RMS information CSA No. 106-M92, BS88:2, IEC 60269:2, CE(amps) catalog offset blades2H07C6H07C15H07C25H07C4H07C10H07C2 0H07C30H07CK07C offset blades40K07C60K07C100K07CR50K07C80K07 CRL14C offset blades80L14C100L14CM14C offset blades125M14C*150M14C*200M14C*L09C center blades80L09C*100L09C*M09C center blades125M09C150M09C200M09CP09C center blades250P09C*300P09C*350P09C*400P09C*P1 1C center blades250P11C300P11C350P11C400P11CR11C center blades450R11C500R11C600R11C* Not suitable for installation in Red Spot fuse applications Used to protect motor control circuits.